Continuous measurements of air change rates in an occupied house for 1 year: the effect of temperature, wind, fans, and windows.

L A Wallace1, S J Emmerich, C Howard-Reed.   

Abstract

A year-long investigation of air change rates in an occupied house was undertaken to establish the effects of temperature, wind velocity, use of exhaust fans, and window-opening behavior. Air change rates were calculated by periodically injecting a tracer gas (SF(6)) into the return air duct and measuring the concentration in 10 indoor locations sequentially every minute by a gas chromatograph equipped with an electron capture detector. Temperatures were also measured outdoors and in the 10 indoor locations. Relative humidity (RH) was measured outdoors and in five indoor locations every 5 min. Wind speed and direction in the horizontal plane were measured using a portable meteorological station mounted on the rooftop. Use of the thermostat-controlled attic fan was recorded automatically. Indoor temperatures increased from 21 degrees C in winter to 27 degrees C in summer. Indoor RH increased from 20% to 70% in the same time period. Windows were open only a few percent of the time in winter but more than half the time in summer. About 4600 hour-long average air change rates were calculated from the measured tracer gas decay rates. The mean (SD) rate was 0.65 (0.56) h(-1). Tracer gas decay rates in different rooms were very similar, ranging only from 0.62 to 0.67 h(-1), suggesting that conditions were well mixed throughout the year. The strongest influence on air change rates was opening windows, which could increase the rate to as much as 2 h(-1) for extended periods, and up to 3 h(-1) for short periods of a few hours. The use of the attic fan also increased air change rates by amounts up to 1 h(-1). Use of the furnace fan had no effect on air change rates. Although a clear effect of indoor-outdoor temperature difference could be discerned, its magnitude was relatively small, with a very large temperature difference of 30 degrees C (54 degrees F) accounting for an increase in the air change rate of about 0.6 h(-1). Wind speed and direction were found to have very little influence on air change rates at this house.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12087436     DOI: 10.1038/sj.jea.7500229

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  21 in total

1.  Determinants of Indoor and Personal Exposure to PM(2.5) of Indoor and Outdoor Origin during the RIOPA Study.

Authors:  Qing Yu Meng; Dalia Spector; Steven Colome; Barbara Turpin
Journal:  Atmos Environ (1994)       Date:  2009-11       Impact factor: 4.798

Review 2.  A review of air exchange rate models for air pollution exposure assessments.

Authors:  Michael S Breen; Bradley D Schultz; Michael D Sohn; Thomas Long; John Langstaff; Ronald Williams; Kristin Isaacs; Qing Yu Meng; Casson Stallings; Luther Smith
Journal:  J Expo Sci Environ Epidemiol       Date:  2013-05-29       Impact factor: 5.563

3.  Influence of environmental temperature on risk of gestational diabetes.

Authors:  Gillian L Booth; Jin Luo; Alison L Park; Denice S Feig; Rahim Moineddin; Joel G Ray
Journal:  CMAJ       Date:  2017-05-15       Impact factor: 8.262

4.  Indoor particulate matter in rural, wood stove heated homes.

Authors:  Erin O Semmens; Curtis W Noonan; Ryan W Allen; Emily C Weiler; Tony J Ward
Journal:  Environ Res       Date:  2015-02-19       Impact factor: 6.498

5.  Air exchange rates and migration of VOCs in basements and residences.

Authors:  L Du; S Batterman; C Godwin; Z Rowe; J-Y Chin
Journal:  Indoor Air       Date:  2015-01-20       Impact factor: 5.770

6.  Predicting residential exposure to phthalate plasticizer emitted from vinyl flooring: sensitivity, uncertainty, and implications for biomonitoring.

Authors:  Ying Xu; Elaine A Cohen Hubal; John C Little
Journal:  Environ Health Perspect       Date:  2010-02       Impact factor: 9.031

7.  The relationship between indoor and outdoor temperature, apparent temperature, relative humidity, and absolute humidity.

Authors:  J L Nguyen; J Schwartz; D W Dockery
Journal:  Indoor Air       Date:  2013-06-18       Impact factor: 5.770

8.  Formation of indoor nitrous acid (HONO) by light-induced NO2 heterogeneous reactions with white wall paint.

Authors:  Vincent Bartolomei; Matthias Sörgel; Sasho Gligorovski; Elena Gómez Alvarez; Adrien Gandolfo; Rafal Strekowski; Etienne Quivet; Andreas Held; Cornelius Zetzsch; Henri Wortham
Journal:  Environ Sci Pollut Res Int       Date:  2014-04-11       Impact factor: 4.223

9.  Air exchange rates from atmospheric CO2 daily cycle.

Authors:  João Dias Carrilho; Mário Mateus; Stuart Batterman; Manuel Gameiro da Silva
Journal:  Energy Build       Date:  2015-04-01       Impact factor: 5.879

10.  Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks.

Authors:  Nan Lin; Marie-Anne Rosemberg; Wei Li; Emily Meza-Wilson; Christopher Godwin; Stuart Batterman
Journal:  Indoor Air       Date:  2020-08-24       Impact factor: 5.770

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.