Literature DB >> 25584304

Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT.

Anil Dhingra1, Nayasha Manchanda2.   

Abstract

BACKGROUND: The creation of glide path reduces the risk of instrument breakage. Glide path is created before using NiTi rotary instrumentation Aim: This study compared the changes in the root canal anatomy after creation of glide path using Path Files (PF) and V Glide Path 2 (VGP2) using Cone Beam Computed Tomography (CBCT).
MATERIALS AND METHODS: Hundred extracted mandibular first molars with curved mesial roots, curvature angles ranging within 20-30 degrees were assigned into two groups (n = 50 each). Glide path was prepared using PF (Group I) and VGP2 (Group II). CBCT images were obtained before and after instrumentation. The technical outcomes were compared at 0, 1, 2, 3, 5 and 7mm intervals. The data was analyzed using t-test and Chi-square test. RESULT: There was a statistical difference between the root canal curvatures and working time between the two groups (p < 0.05). Canals transported towards the distal side in Group II but there was a slight mesial transportation in Group I at 0mm. Group I exhibited a better centric ability except at 1mm interval (p > 0.05). The changes in the volume were statistically significant only at 2mm interval (p < 0.05). The difference in the cross sectional area was not statistically significant at any interval (p > 0.05).
CONCLUSION: Within the limits of this study the rotary Nickel Titanium Path Files appeared to be suitable instruments for safe and easy creation of glide path.

Entities:  

Keywords:  Nickel Titanium; Root canal; root canal preparation

Year:  2014        PMID: 25584304      PMCID: PMC4290320          DOI: 10.7860/JCDR/2014/8702.5101

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  34 in total

1.  Torque during canal instrumentation using rotary nickel-titanium files.

Authors:  B Sattapan; J E Palamara; H H Messer
Journal:  J Endod       Date:  2000-03       Impact factor: 4.171

2.  The outcome of endodontic retreatment: a 2-yr follow-up.

Authors:  Fabio G M Gorni; Massimo M Gagliani
Journal:  J Endod       Date:  2004-01       Impact factor: 4.171

3.  Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.

Authors:  E Schäfer; M Vlassis
Journal:  Int Endod J       Date:  2004-04       Impact factor: 5.264

4.  The endodontic Glidepath: "Secret to rotary safety".

Authors:  John D West
Journal:  Dent Today       Date:  2010-09

5.  Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.

Authors:  E Schäfer; M Erler; T Dammaschke
Journal:  Int Endod J       Date:  2006-03       Impact factor: 5.264

Review 6.  Digital and advanced imaging in endodontics: a review.

Authors:  Madhu K Nair; Umadevi P Nair
Journal:  J Endod       Date:  2007-01       Impact factor: 4.171

7.  The influence of various automated devices on the shaping ability of Mtwo rotary nickel-titanium instruments.

Authors:  S Bürklein; E Schäfer
Journal:  Int Endod J       Date:  2006-12       Impact factor: 5.264

8.  Cleaning and shaping the root canal.

Authors:  H Schilder
Journal:  Dent Clin North Am       Date:  1974-04

9.  Relationship between file size and stiffness of nickel titanium instruments.

Authors:  J J Camps; W J Pertot; B Levallois
Journal:  Endod Dent Traumatol       Date:  1995-12

10.  Canal orifice enlargement as related to biomechanical preparation.

Authors:  J Leeb
Journal:  J Endod       Date:  1983-11       Impact factor: 4.171

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.