Literature DB >> 25572948

Anterior choroidal artery patency and clinical follow-up after coverage with the pipeline embolization device.

E Raz1, M Shapiro2, T Becske2, D W Zumofen3, O Tanweer4, M B Potts4, H A Riina3, P K Nelson5.   

Abstract

BACKGROUND AND
PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment.
MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed.
RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found.
CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2015        PMID: 25572948      PMCID: PMC7990596          DOI: 10.3174/ajnr.A4217

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  21 in total

1.  Variable porosity of the pipeline embolization device in straight and curved vessels: a guide for optimal deployment strategy.

Authors:  M Shapiro; E Raz; T Becske; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-26       Impact factor: 3.825

2.  Perforator infarction after placement of a pipeline flow-diverting stent for an unruptured A1 aneurysm.

Authors:  W J van Rooij; M Sluzewski
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

3.  Building multidevice pipeline constructs of favorable metal coverage: a practical guide.

Authors:  M Shapiro; E Raz; T Becske; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-27       Impact factor: 3.825

4.  Anterior choroidal artery: angiographic analysis of variations and anomalies.

Authors:  S Takahashi; T Suga; Y Kawata; K Sakamoto
Journal:  AJNR Am J Neuroradiol       Date:  1990 Jul-Aug       Impact factor: 3.825

5.  Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

Authors:  Tibor Becske; David F Kallmes; Isil Saatci; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Christopher J Moran; Henry H Woo; Demetrius K Lopes; Aaron L Berez; Daniel J Cher; Adnan H Siddiqui; Elad I Levy; Felipe C Albuquerque; David J Fiorella; Zsolt Berentei; Miklós Marosfoi; Saruhan H Cekirge; Peter K Nelson
Journal:  Radiology       Date:  2013-02-15       Impact factor: 11.105

6.  Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms.

Authors:  Ross C Puffer; David F Kallmes; Harry J Cloft; Giuseppe Lanzino
Journal:  J Neurosurg       Date:  2012-01-06       Impact factor: 5.115

7.  Anterior choroidal artery ischaemic patterns predict outcome of carotid occlusion.

Authors:  Meng Lee; Jeffrey L Saver; Qing Hao; Sidney Starkman; Noriko Salamon; Latisha K Ali; Doojin Kim; Bruce Ovbiagele; Sarah Song; Radoslav Raychev; Hermelind Abcede; Rana Fiaz; David S Liebeskind
Journal:  J Neurol Neurosurg Psychiatry       Date:  2012-04-04       Impact factor: 10.154

8.  Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms.

Authors:  D Fiorella; P Lylyk; I Szikora; M E Kelly; F C Albuquerque; C G McDougall; P K Nelson
Journal:  J Neurointerv Surg       Date:  2009-06-16       Impact factor: 5.836

9.  In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit.

Authors:  Jaehoon Seong; Ajay K Wakhloo; Baruch B Lieber
Journal:  J Biomech Eng       Date:  2007-12       Impact factor: 2.097

10.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

View more
  15 in total

1.  Patency of anterior choroidal artery after flow diverter deployment with assessment of magnetic resonance imaging follow-up.

Authors:  Takashi Fujii; Hidenori Oishi; Kohsuke Teranishi; Kenji Yatomi; Munetaka Yamamoto; Hajime Arai
Journal:  Neuroradiol J       Date:  2018-12-03

2.  Stepwise stent deployment technique for tandem intracranial aneurysms: a review of 21 cases.

Authors:  Yi-Bin Fang; Zhao-Long Zhang; Peng-Fei Yang; Wan-Ling Wen; Bo Hong; Yi Xu; Wen-Yuan Zhao; Qing-Hai Huang; Jian-Min Liu
Journal:  Eur Radiol       Date:  2015-05-26       Impact factor: 5.315

3.  Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study.

Authors:  J M Ospel; G Gascou; V Costalat; L Piergallini; K A Blackham; D W Zumofen
Journal:  AJNR Am J Neuroradiol       Date:  2019-02-07       Impact factor: 3.825

4.  Posterior Inferior Cerebellar Artery Patency after Flow-Diverting Stent Treatment.

Authors:  M R Levitt; M S Park; F C Albuquerque; K Moon; M Y S Kalani; C G McDougall
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

5.  Complication Risk Factors in Anterior Choroidal Artery Aneurysm Treatment.

Authors:  Arthur André; Anne-Laure Boch; Federico Di Maria; Aurélien Nouet; Nader Sourour; Stéphane Clémenceau; Joseph Gabrieli; Vincent Degos; Chiheb Zeghal; Jacques Chiras; Philippe Cornu; Frédéric Clarençon
Journal:  Clin Neuroradiol       Date:  2017-03-20       Impact factor: 3.649

6.  Toward Better Understanding of Flow Diversion in Bifurcation Aneurysms.

Authors:  M Shapiro; A Shapiro; E Raz; T Becske; H Riina; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2018-11-15       Impact factor: 3.825

7.  Application of flow diverters in the treatment of aneurysms in the internal carotid artery bifurcation region.

Authors:  Mostafa Mahmoud; Ahmed Farag; Mostafa Farid; Ahmed Elserwi; Amr Abdelsamad; Wessam Guergues; Farouk Hassan
Journal:  Neuroradiol J       Date:  2020-05-18

8.  Neck Location on the Outer Convexity is a Predictor of Incomplete Occlusion in Treatment with the Pipeline Embolization Device: Clinical and Angiographic Outcomes.

Authors:  T Sunohara; H Imamura; M Goto; R Fukumitsu; S Matsumoto; N Fukui; Y Oomura; T Akiyama; T Fukuda; K Go; S Kajiura; M Shigeyasu; K Asakura; R Horii; C Sakai; N Sakai
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-12       Impact factor: 3.825

9.  Comparison of endovascular treatment for middle cerebral artery aneurysm with a low-profile visualized intraluminal support stent or pipeline embolization device.

Authors:  Peng Lu; Ye Zhang; Huanjiang Niu; Yirong Wang
Journal:  Exp Ther Med       Date:  2019-07-16       Impact factor: 2.447

10.  Anterior Communicating Artery Aneurysm Treatment with the Pipeline Embolization Device: A Single-Center Experience with Long-Term Follow-Up.

Authors:  Ali Sultan-Qurraie; Ahsan Sattar; Wled Wazni; Mazen Noufal; Osama Zaidat
Journal:  Interv Neurol       Date:  2017-02-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.