Real-time continuous glucose monitoring in type 1 diabetes: a qualitative framework analysis of patient narratives.

John C Pickup1, Melissa Ford Holloway2, Kritika Samsi3.   

Abstract

OBJECTIVE: This study analyzed narratives about experiences of real-time continuous glucose monitoring (CGM) in people with type 1 diabetes. RESEARCH DESIGN AND METHODS: People with type 1 diabetes using CGM and caregivers completed an online survey. Questions included duration of CGM, frequency of sensor wear, funding, and a free narrative about experiences or views about CGM. We used qualitative framework analysis to analyze 100 responses; 50% of participants were aged ≥ 18 years.
RESULTS: Most participants (87%) used CGM with insulin pump therapy, 71% used sensors ≥ 75% of the time, and 66% received funding for CGM from the National Health Service. Four themes were identified: 1) metabolic control, 2) living with CGM (work and school, sleep, exercise, nutrition, frequency of self-monitoring of blood glucose [SMBG]), 3) psychological issues and patient/caregiver attitudes, and 4) barriers to CGM use (technical issues, financial issues, attitudes of healthcare professionals toward CGM). Despite some hassles, experiences were overwhelmingly positive, with improved glycemic control, diet and exercise management, quality of life, and physical and psychological well-being, as well as reduced frequency of SMBG. Technical problems included sensor inaccuracy and unreliability, and "alarm fatigue." The advantages of CGM used with an insulin pump with automatic suspension of insulin delivery during hypoglycemia were recorded by several participants, noting reduced hypoglycemia frequency and fear of nocturnal hypoglycemia.
CONCLUSIONS: Patient and caregiver narratives indicate that CGM is a valuable addition to diabetes care for many with type 1 diabetes.
© 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25552422     DOI: 10.2337/dc14-1855

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  45 in total

1.  Bolus Estimation--Rethinking the Effect of Meal Fat Content.

Authors:  Srinivas Laxminarayan; Jaques Reifman; Stephanie S Edwards; Howard Wolpert; Garry M Steil
Journal:  Diabetes Technol Ther       Date:  2015-08-13       Impact factor: 6.118

2.  Hypoglycemia Reduction and Accuracy of Continuous Glucose Monitoring.

Authors:  Boris P Kovatchev
Journal:  Diabetes Technol Ther       Date:  2015-05-15       Impact factor: 6.118

3.  Analysis: The Accuracy and Efficacy of the Dexcom G4 Platinum Continuous Glucose Monitoring System.

Authors:  Cornelis A J van Beers; J H DeVries
Journal:  J Diabetes Sci Technol       Date:  2015-04-27

4.  Minimally Disruptive Diabetes Care for the Elderly.

Authors:  Gabriela Spencer-Bonilla; Rene Rodriguez-Gutierrez; Victor M Montori
Journal:  Diabetes Technol Ther       Date:  2016-12       Impact factor: 6.118

5.  Development of a Novel Tool to Support Engagement With Continuous Glucose Monitoring Systems and Optimize Outcomes.

Authors:  Katharine D Barnard-Kelly; William H Polonsky
Journal:  J Diabetes Sci Technol       Date:  2019-05-21

6.  Continuous Glucose Monitoring Associated With Less Diabetes-Specific Emotional Distress and Lower A1c Among Adolescents With Type 1 Diabetes.

Authors:  Anthony T Vesco; Aneta M Jedraszko; Kimberly P Garza; Jill Weissberg-Benchell
Journal:  J Diabetes Sci Technol       Date:  2018-03-29

Review 7.  Diabetes technologies - what the general physician needs to know.

Authors:  Adrian Li; Sufyan Hussain
Journal:  Clin Med (Lond)       Date:  2020-09       Impact factor: 2.659

Review 8.  Continuous Glucose Monitoring Integration in Clinical Practice: A Stepped Guide to Data Review and Interpretation.

Authors:  Grazia Aleppo; Kimberly Webb
Journal:  J Diabetes Sci Technol       Date:  2018-11-19

9.  MiniMed 670G hybrid closed loop artificial pancreas system for the treatment of type 1 diabetes mellitus: overview of its safety and efficacy.

Authors:  Aria Saunders; Laurel H Messer; Gregory P Forlenza
Journal:  Expert Rev Med Devices       Date:  2019-09-30       Impact factor: 3.166

10.  Recruitment Into a Pediatric Continuous Glucose Monitoring RCT.

Authors:  Lisa K Volkening; Kaitlin C Gaffney; Michelle L Katz; Lori M Laffel
Journal:  J Diabetes Sci Technol       Date:  2016-07-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.