Literature DB >> 25917336

Analysis: The Accuracy and Efficacy of the Dexcom G4 Platinum Continuous Glucose Monitoring System.

Cornelis A J van Beers1, J H DeVries2.   

Abstract

In this issue of Journal of Diabetes Science and Technology, Nakamura and Balo report on accuracy and efficacy of the Dexcom G4 Platinum Continuous Glucose Monitoring System. The authors demonstrate good overall performance of this real-time continuous glucose monitoring (RT-CGM) system, although accuracy data of the next generation RT-CGM system, the G4AP, is already available. Also, now that MARDs seem to move to single-digit numbers, the question comes up how low we need to go with accuracy. Results of the study also showed a reduction in time spent in hypoglycemia, although the clinical relevance should be questioned. To date, few trials have demonstrated a reduction of severe hypoglycemia. Conventional RT-CGM, without threshold suspension or closing the loop, might be insufficient in preventing severe hypoglycemia.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  Dexcom G4 Platinum; continuous glucose monitoring; continuous glucose monitoring accuracy; diabetes mellitus

Mesh:

Substances:

Year:  2015        PMID: 25917336      PMCID: PMC4667343          DOI: 10.1177/1932296815583508

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  24 in total

1.  Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes.

Authors:  Richard M Bergenstal; William V Tamborlane; Andrew Ahmann; John B Buse; George Dailey; Stephen N Davis; Carol Joyce; Tim Peoples; Bruce A Perkins; John B Welsh; Steven M Willi; Michael A Wood
Journal:  N Engl J Med       Date:  2010-06-29       Impact factor: 91.245

2.  Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial.

Authors:  J Hermanides; K Nørgaard; D Bruttomesso; C Mathieu; A Frid; C M Dayan; P Diem; C Fermon; I M E Wentholt; J B L Hoekstra; J H DeVries
Journal:  Diabet Med       Date:  2011-10       Impact factor: 4.359

3.  Satisfaction with continuous glucose monitoring in adults and youths with Type 1 diabetes.

Authors:  M Tansey; L Laffel; J Cheng; R Beck; J Coffey; E Huang; C Kollman; J Lawrence; J Lee; K Ruedy; W Tamborlane; T Wysocki; D Xing
Journal:  Diabet Med       Date:  2011-09       Impact factor: 4.359

4.  Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

Authors:  Jean Halford; Claudia Harris
Journal:  Diabetes Technol Ther       Date:  2010-03       Impact factor: 6.118

5.  Psychosocial correlates of continuous glucose monitoring use in youth and adults with type 1 diabetes and parents of youth.

Authors:  Jessica T Markowitz; Katherine Pratt; Jyoti Aggarwal; Lisa K Volkening; Lori M B Laffel
Journal:  Diabetes Technol Ther       Date:  2012-04-23       Impact factor: 6.118

6.  What are the quality of life-related benefits and losses associated with real-time continuous glucose monitoring? A survey of current users.

Authors:  William H Polonsky; Danielle Hessler
Journal:  Diabetes Technol Ther       Date:  2013-02-21       Impact factor: 6.118

7.  A new-generation continuous glucose monitoring system: improved accuracy and reliability compared with a previous-generation system.

Authors:  Mark Christiansen; Timothy Bailey; Elaine Watkins; David Liljenquist; David Price; Katherine Nakamura; Robert Boock; Thomas Peyser
Journal:  Diabetes Technol Ther       Date:  2013-06-18       Impact factor: 6.118

8.  Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Authors:  Richard M Bergenstal; David C Klonoff; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew J Ahmann; John B Welsh; Scott W Lee; Francine R Kaufman
Journal:  N Engl J Med       Date:  2013-06-22       Impact factor: 91.245

9.  Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes.

Authors:  Tadej Battelino; Moshe Phillip; Natasa Bratina; Revital Nimri; Per Oskarsson; Jan Bolinder
Journal:  Diabetes Care       Date:  2011-02-19       Impact factor: 19.112

10.  The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial.

Authors:  T Battelino; I Conget; B Olsen; I Schütz-Fuhrmann; E Hommel; R Hoogma; U Schierloh; N Sulli; J Bolinder
Journal:  Diabetologia       Date:  2012-09-11       Impact factor: 10.122

View more
  1 in total

1.  Inaccurate Glucose Sensor Values After Hydroxyurea Administration.

Authors:  Siobhan E Tellez; Lindsey N Hornung; Joshua D Courter; Maisam Abu-El-Haija; Jaimie D Nathan; Sarah A Lawson; Deborah A Elder
Journal:  Diabetes Technol Ther       Date:  2020-12-30       Impact factor: 7.337

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.