Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose.

Rui Yan1, Longmei Qu2, Nan Luo2, Yang Liu1, Yu Liu1, Li Li1, Lijiang Chen1.   

Abstract

Lactose is a widely used pharmaceutical excipient, sometimes irreplaceable. Traces of residual proteins left during production of lactose are potential allergen to body. The present paper describes a sensitive and specific LC-MS method for the determination of α-lactalbumin (α-La) in lactose samples. Chromatographic separation was performed on an Acquity UPLC BEH300 C18 column (2.1 × 150 mm, 1.7 μm) with an isocratic mobile phase consisting of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v). Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. Quantitation was performed using selected ion monitoring of m/z 2364 for α-La. The calibration curve was linear from 0.2 to 10 µg/mL. The intra- and interday precisions were less than 7.6% and the accuracy ranged from 96.4 to 104.5%. The limit of quantification (LOQ) was 0.15 µg/mL and the limit of detection (LOD) was 0.05 µg/mL. This method was then successfully applied to investigate 6 different lactose samples. The application can provide technical preparation for the development of specification of lactose.

Entities:  

Year:  2014        PMID: 25548567      PMCID: PMC4273475          DOI: 10.1155/2014/841084

Source DB:  PubMed          Journal:  Int J Anal Chem        ISSN: 1687-8760            Impact factor:   1.885


1. Introduction

Lactose is commonly used as an inactive ingredient in many pharmaceutical formulations including tablets, suspensions, dry powder inhalers, and medicines for injection. Since lactose is manufactured from bovine whey, through degreasing, protein removing, concentrating, crystallizing, and drying, residual whey protein is inevitable in lactose products. Recently, allergy reactions of injections containing lactose in clinical practice were reported, where the allergen was residual whey proteins [1]. A previous report described a cow's milk allergy in an asthmatic patient who had an anaphylactic reaction to the milk protein in a dry powder inhaler containing both salmeterol and fluticasone [2]. In addition, residual proteins can provide nutrient components to stimulate the growth of viruses so that lactose may carry some viruses. The residual proteins include α-lactalbumin (α-La), β-lactoglobulin (β-Lg), bovine serum albumin (BSA), immunoglobulin (Ig), and other albumins. “China biological products procedures” only include the stipulation that the content of residual BSA should not exceed 50 ng/mL per person. However, Pharmacopoeia of China or other countries record no relevant quality specifications on lactose for injection so far. It is urgent to develop determination methods for residual protein in lactose for injection to investigate the quality of the pharmaceutical adjuvant. Traditional methods for proteins determination include Kjeldahl method, Lowry method, and Bradford method. In recent years, some publications have described methods utilizing IR [3], CE [4], amino acid analysis [5], and spectrophotometry [6, 7] to quantify proteins in complex matrices. Yang et al. reported a modified Kjeldahl method for the quantification of residual protein in lactose for injection [8]. More and more experimental applications prove that LC-MS is a powerful determination tool for proteins due to the versatility, high resolution, and short analysis time of the method [9-11]. As one of the most important allergens in lactose, α-La was determined in medicinal lactose by a capillary zone electrophoresis (CZE) method with a LOD of 3.0 μg/mL [12]. In the present study, a suitable LC-MS method for determination of α-La in lactose for injection was established. Application of the method to commercial lactose samples could provide references for relevant drug administration to set limits of residual α-La for lactose for injection.

2. Experimental

2.1. Materials

α-Lactalbumin (purity ≥ 85%) protein standards were purchased from Shanghai Yuanye Bio-Technology Co., Ltd. (Shanghai, China). Acetonitrile and methanol were of HPLC grade (Sigma-Aldrich, St. Louis, MO, USA). Acetic acid, formic acid, trifluoroacetic acid (TFA), and other solvents were of analytical grade. High quality poly(9,9-diethylfluorene) (PDEF) syringe filters (0.22 μm pore size; 13 mm diameter) were purchased from Sigma-Aldrich. Watsons pure distilled water was used (A.S. Watson Group Ltd., Hong Kong).

2.2. Instrumentation

The LC-MS/MS system consisted of an Agilent 1290 series liquid chromatograph and an Agilent 6460 triple-quadrupole mass spectrometer (Agilent Technologies, Inc., USA) with electrospray ionization. Data acquisition and processing were processed using the Agilent MassHunter Chemstation (B.01.03). Separation of peptides was performed on a narrow-bore Acquity UPLC BEH300 C18 column (2.1 × 150 mm, 1.7 μm) from Waters (Milford, MA, USA), maintained at 30°C. The mobile phase consisted of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v) with a flow rate of 0.1 mL/min, and the injection volume was 10 μL. The Dual AJS electrospray ion source was operated in the positive ion mode (the gas temperature, 350°C; drying gas, 13 L/min; nebulizer, 45 psig; sheath gas temperature, 250°C; sheath gas flow, 11 L/min; VCap, 3500 V; nozzle voltage, 1000 V; fragmentor, 320 V). Quantitation was performed under the selected ion monitoring mode (SIM) of m/z 2364.

2.3. Preparation of Blank Matrix

0.2 g of lactose (batch number: K43367545237) was weighted accurately and dissolved in 25 mL water. The solution passed through a 0.22 μm filter and was ready for injection.

2.4. Preparation of Standard Solutions

The stock solutions (1 mg/mL) of bovine α-La were prepared in water. A mixed stock solution containing 100 μg/mL of bovine α-La was prepared in the blank matrix. All stock solutions were stored in the dark at −20°C for no more than 1 month. Work standard solutions were prepared from these stock solutions and were diluted step by step with the blank matrix immediately before using.

2.5. Sample Preparation

0.2 g of lactose sample was weighted accurately and dissolved in 25 mL water. The solution passed through a 0.22 μm filter and was ready for injection.

3. Results and Discussion

3.1. Optimization of LC-MS/MS for Quantitative Analysis

The full-scan spectra of the bovine α-La are shown in Figure 1; peak of 6+ (m/z, 2364) charge state was chosen because of the high relative abundance. To obtain maximum sensitivity of the SIM, some parameters such as spray voltage, capillary temperature, sheath gas flow, and nebulizer pressure were optimized. The other MS parameters were adopted from the recommended values for the instrument.
Figure 1

The original mass spectra of bovine α-La.

The optimization of chromatographic conditions was mainly guided by the requirement for quantifying assay and reducing the analytical run time. Different compositions of mobile phase were compared for their separation efficiency. The results showed that TFA is indispensable for obtaining good chromatographic peaks that the selected mobile phase as Section 2.2 could provide specificity and proper retention time. Each chromatographic run was completed within 5 min.

3.2. Analytical Performance

To validate the LC-MS method for determination of bovine α-La in lactose, the analytical performance of the method should be satisfactory with the linearity, sensitivity, recovery, precision, and repeatability.

3.2.1. Linearity and Sensitivity

The calibration curve was established after injection of the standard solutions in duplicate at six concentrations. α-La standard solution, with the concentration sequence of 0.2, 0.4, 1.0, 2.0, 4.0, and 10.0 μg/mL, was prepared in mobile phase. All calibration curves were linear over the range of 0.2–10.0 μg/mL with correlation coefficients (R 2) ≥ 0.9991. The limit of detection (LOD) and limit of quantitation (LOQ) were the concentrations of a compound at which its signal-to-noise ratios were detected as 3 : 1 and 10 : 1, respectively. They were determined by serial dilution of sample solutions under the described LC-MS conditions. The LOD and LOQ of α-La were 0.05 and 0.15 μg/mL, respectively.

3.2.2. Recovery and Precision

Recovery was performed employing the method of standard addition. Low, intermediate, and high levels of α-La standards were added to approximately 0.1 g of sample, the content of which had been determined. The sample was then processed and analyzed as described in Section 2.5. Three parallel samples were prepared and the assay was repeated three times. The results are summarized in Table 1. All recoveries were in the range of 96.4–104.5%.
Table 1

Recovery and intra- and interday precision of LC-MS method (n = 3).

Nominal (μg/mL)Recovery (%)Precision (%)
MeanRSD%IntradayInterday
0.4104.56.33.15.5
296.42.94.77.6
898.63.61.82.3
The precision of the method was evaluated by six replicate analyses of the same lactose sample over consecutive three days. Intra- and interday precision at low, intermediate, and high concentration levels are listed in Table 1. The RSDs were in the range of 1.8–4.7% for intraday precision and 2.3–7.6% for interday precision.

3.2.3. Repeatability

The repeatability of the LC-MS method was studied by determining the variation in relative MS response when analyzing the same lactose with 6 sample preparations. The RSDs were ≤5.7%.

3.2.4. Stability

The stability of the analytes in the prepared samples stored at room temperature was investigated by replicate injection of the sample solution at 0, 2, 4, 8, and 12 h. The RSDs of the assay results at different time intervals were 1.6–3.5%, which indicated that the sample solution was stable at room temperature for at least 12 h.

3.3. Method Application

The validated analytical method was applied to 6 lactose samples from different sources. A representative SIM chromatogram of the lactose sample is shown in Figure 2. The quantitative results were summarized in Table 2.
Figure 2

Representative SIM chromatograms for α-La of (a) water, (b) water spiked with α-La at the LLOQ, and (c) a lactose sample.

Table 2

Detected contents of α-La (μg/g) in six commercial lactose samples from different sources.

Batch numberK4336754523711008L1139106704731069193110652704

Mass fractions (μg/g)Not detected52.778.446.339.554.3

4. Conclusion

A sensitive and selective LC-MS method was developed for the determination of bovine α-lactalbumin in pharmaceutical adjuvant lactose. The method has the LOQ of 0.15 μg/mL and allows accurate quantification of low levels of α-La. It was successfully applied to determine bovine α-La in six different lactose samples. This paper proved that it is feasible to assay residual proteins in lactose using LC-MS and also prepared for the development of quality control of lactose for injection and other pharmaceutical adjuvants containing α-La. Its application might be helpful to pharmaceutical enterprise on new drug registration.
  10 in total

1.  Contamination of dry powder inhalers for asthma with milk proteins containing lactose.

Authors:  Anna Nowak-Wegrzyn; Gail G Shapiro; Kirsten Beyer; Ludmila Bardina; Hugh A Sampson
Journal:  J Allergy Clin Immunol       Date:  2004-03       Impact factor: 10.793

2.  Absolute quantitation of beta-lactoglobulin by protein liquid chromatography-mass spectrometry and its application to different milk products.

Authors:  Christoph Czerwenka; Irene Maier; Natascha Potocnik; Fritz Pittner; Wolfgang Lindner
Journal:  Anal Chem       Date:  2007-06-08       Impact factor: 6.986

3.  Multi-dimension microchip-capillary electrophoresis device for determination of functional proteins in infant milk formula.

Authors:  Ruige Wu; Zhiping Wang; Wenfeng Zhao; William Shu-Biu Yeung; Ying Sing Fung
Journal:  J Chromatogr A       Date:  2013-07-02       Impact factor: 4.759

4.  Simultaneous determination of bovine alpha-lactalbumin and beta-lactoglobulin in infant formulae by ultra-high-performance liquid chromatography-mass spectrometry.

Authors:  Yiping Ren; Zheng Han; Xiaojun Chu; Jingshun Zhang; Zengxuan Cai; Yongjiang Wu
Journal:  Anal Chim Acta       Date:  2010-04-13       Impact factor: 6.558

5.  Determination of grain protein content by near-infrared spectrometry and multivariate calibration in barley.

Authors:  Chen Lin; Xue Chen; Lei Jian; Chunhai Shi; Xiaoli Jin; Guoping Zhang
Journal:  Food Chem       Date:  2014-04-24       Impact factor: 7.514

6.  Multiple reaction monitoring-based determination of bovine α-lactalbumin in infant formulas and whey protein concentrates by ultra-high performance liquid chromatography-tandem mass spectrometry using tryptic signature peptides and synthetic peptide standards.

Authors:  Jingshun Zhang; Shiyun Lai; Yu Zhang; Baifen Huang; Duo Li; Yiping Ren
Journal:  Anal Chim Acta       Date:  2012-03-29       Impact factor: 6.558

7.  Determination of protein concentration for protein-protein conjugates using ultraviolet absorption.

Authors:  Daming Zhu; Feng Qian; Yimin Wu; David S Jones; Christopher Rowe; David L Narum; Patrick Duffy; Louis H Miller; Allan Saul
Journal:  J Immunol Methods       Date:  2012-10-23       Impact factor: 2.303

8.  A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

Authors:  Qin-Qin Liang; Yong-Sheng Li
Journal:  Food Chem       Date:  2013-05-23       Impact factor: 7.514

9.  Detection of tropomyosin and determination of proteins in crustacean oils.

Authors:  Birthe Vang; Hanne K Mæhre; Ida-J Jensen; Ragnar L Olsen
Journal:  Food Chem       Date:  2013-03-14       Impact factor: 7.514

10.  Acute allergic reaction due to milk proteins contaminating lactose added to corticosteroid for injection.

Authors:  Asuka Eda; Kazuko Sugai; Hiromi Shioya; Asako Fujitsuka; Setsuko Ito; Tsutomu Iwata; Tetsunori Funabiki
Journal:  Allergol Int       Date:  2009-01-25       Impact factor: 5.836

  10 in total
  1 in total

1.  Simultaneous detection of α-Lactoalbumin, β-Lactoglobulin and Lactoferrin in milk by Visualized Microarray.

Authors:  Zhoumin Li; Fang Wen; Zhonghui Li; Nan Zheng; Jindou Jiang; Danke Xu
Journal:  BMC Biotechnol       Date:  2017-09-12       Impact factor: 2.563

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.