Literature DB >> 23870546

Multi-dimension microchip-capillary electrophoresis device for determination of functional proteins in infant milk formula.

Ruige Wu1, Zhiping Wang, Wenfeng Zhao, William Shu-Biu Yeung, Ying Sing Fung.   

Abstract

To improve resolution of important minor proteins and eliminate time-consuming precipitation of major protein with associated analyte co-precipitation risk, a multi-dimension strategy is adopted in the 2D microchip-CE device to isolate major proteins on-chip, enrich minor proteins in capillary before their separation in CE for UV quantitation. A standard fluorescent protein mixture containing FITC-BSA, myoglobin and cytochrome as specific pI markers has prepared to demonstrate capability of the device to fractionate minor proteins by IEF. The results using a standard protein mixture with profile resembling infant milk formula show a complete isolation of high abundance proteins by a 2-min 1D IEF run. The subsequent t-ITP/CZE run by on-chip high voltage switching delivers a high stacking ratio, realizing 60 folds enrichment of isolated protein fractions. All five important functional proteins (LF, IgG, α-LA, β-LgA and β-LgB) known to fortify infant milk formula are isolated and determined using two consecutive t-ITP-CZE runs within a 18-min total assay time, a significant saving compared to several hours conventional pretreatment. For a 100g infant milk formula sample, working ranges of 20-8000mg, repeatability 3.8-5.3% and detection limits 2.3-10mg have been achieved to meet government regulations. Method reliability is established by 100% recoveries and agreeable results within expected ranges and labeled values. The capability of the device for field operation, rapid assay with quick results, label-free universal detection, simple operation by aqueous dissolution before injection, and the demanding matching in 2D separation based on isolated fractions at specified pI ranges, closely matched migration time and baseline-resolved peak shape makes the device a general tool to detect unknown proteins and determine known minor proteins in protein-rich samples with interfering constituents.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Functional protein; Infant milk formula; Isoelectric focusing; Isotachophoresis; Microchip-capillary electrophoresis device

Mesh:

Substances:

Year:  2013        PMID: 23870546     DOI: 10.1016/j.chroma.2013.06.073

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose.

Authors:  Rui Yan; Longmei Qu; Nan Luo; Yang Liu; Yu Liu; Li Li; Lijiang Chen
Journal:  Int J Anal Chem       Date:  2014-12-04       Impact factor: 1.885

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.