Literature DB >> 25545341

Intravascular optical coherence tomography light scattering artifacts: merry-go-rounding, blooming, and ghost struts.

J Jacob Mancuso1, David L Halaney1, Sahar Elahi2, Derek Ho2, Tianyi Wang2, Yongjian Ouyang3, Jouke Dijkstra4, Thomas E Milner2, Marc D Feldman1.   

Abstract

We sought to elucidate the mechanisms underlying two common intravascular optical coherence tomography (IV-OCT) artifacts that occur when imaging metallic stents: “merry-go-rounding” (MGR), which is an increase in strut arc length (SAL), and “blooming,” which is an increase in the strut reflection thickness (blooming thickness). Due to uncontrollable variables that occur in vivo, we performed an in vitro assessment of MGR and blooming in stented vessel phantoms. Using Xience V and Driver stents, we examined the effects of catheter offset, intimal strut coverage, and residual blood on SAL and blooming thickness in IV-OCT images. Catheter offset and strut coverage both caused minor MGR, while the greatest MGR effect resulted from light scattering by residual blood in the vessel lumen, with 1% hematocrit (Hct) causing a more than fourfold increase in SAL compared with saline (p<0.001 ). Residual blood also resulted in blooming, with blooming thickness more than doubling when imaged in 0.5% Hct compared with saline (p<0.001 ). We demonstrate that a previously undescribed mechanism, light scattering by residual blood in the imaging field, is the predominant cause of MGR. Light scattering also results in blooming, and a newly described artifact, three-dimensional-MGR, which results in “ghost struts” in B-scans.

Entities:  

Mesh:

Year:  2014        PMID: 25545341      PMCID: PMC4659478          DOI: 10.1117/1.JBO.19.12.126017

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  14 in total

Review 1.  Intracoronary optical diagnostics current status, limitations, and potential.

Authors:  Harry C Lowe; Jagat Narula; James G Fujimoto; Ik-Kyung Jang
Journal:  JACC Cardiovasc Interv       Date:  2011-12       Impact factor: 11.195

2.  Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables.

Authors:  J W Bartlett; C Frost
Journal:  Ultrasound Obstet Gynecol       Date:  2008-04       Impact factor: 7.299

3.  Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage.

Authors:  Peter Barlis; Konstantinos Dimopoulos; Jun Tanigawa; Ewa Dzielicka; Giuseppe Ferrante; Francesca Del Furia; Carlo Di Mario
Journal:  Int J Cardiol       Date:  2009-01-19       Impact factor: 4.164

4.  Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography.

Authors:  Mitsuyasu Terashima; Sudhir Rathore; Yasuyoshi Suzuki; Yoshiaki Nakayama; Hideaki Kaneda; Kenya Nasu; Maoto Habara; Osamu Katoh; Takahiko Suzuki
Journal:  J Invasive Cardiol       Date:  2009-11       Impact factor: 2.022

5.  The impact of an eccentric intravascular ImageWire during coronary optical coherence tomography imaging.

Authors:  Nobuaki Suzuki; Giulio Guagliumi; Hirama G Bezerra; Vasile Sirbu; Noah Rosenthal; Giuseppe Musumeci; Alessandro Aprile; Hui Wang; Hiroyuki Kyono; Satoko Tahara; Daniel I Simon; Andrew Rollins; Marco A Costa
Journal:  EuroIntervention       Date:  2011-03       Impact factor: 6.534

6.  Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation.

Authors:  Akira Murata; David Wallace-Bradley; Armando Tellez; Carlos Alviar; Michael Aboodi; Alexander Sheehy; Leslie Coleman; Laura Perkins; Gaku Nakazawa; Gary Mintz; Greg L Kaluza; Renu Virmani; Juan F Granada
Journal:  JACC Cardiovasc Imaging       Date:  2010-01-12

7.  Diagnostic accuracy of CT angiography to assess coronary stent thrombosis as determined by intravascular OCT.

Authors:  Takashi Kubo; Yoshiki Matsuo; Yasushi Ino; Hironori Kitabata; Takashi Tanimoto; Kohei Ishibashi; Yasushi Okumoto; Kenji Nakamura; Kenichi Komukai; Shigeho Takarada; Atsushi Tanaka; Toshio Imanishi; Hideharu Akagi; Takashi Akasaka
Journal:  JACC Cardiovasc Imaging       Date:  2011-09

Review 8.  Assessment of coronary stent by optical coherence tomography, methodology and definitions.

Authors:  Emile Aziz Mehanna; Guilherme Ferragut Attizzani; Hiroyuki Kyono; Michael Hake; Hiram Grando Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-19       Impact factor: 2.357

Review 9.  Optical coherence tomography endpoints in stent clinical investigations: strut coverage.

Authors:  Satoko Tahara; Daniel Chamié; Motaz Baibars; Chadi Alraies; Marco Costa
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

Review 10.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications.

Authors:  Hiram G Bezerra; Marco A Costa; Giulio Guagliumi; Andrew M Rollins; Daniel I Simon
Journal:  JACC Cardiovasc Interv       Date:  2009-11       Impact factor: 11.195

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.