Literature DB >> 19926041

Intracoronary optical coherence tomography: a comprehensive review clinical and research applications.

Hiram G Bezerra1, Marco A Costa, Giulio Guagliumi, Andrew M Rollins, Daniel I Simon.   

Abstract

Cardiovascular optical coherence tomography (OCT) is a catheter-based invasive imaging system. Using light rather than ultrasound, OCT produces high-resolution in vivo images of coronary arteries and deployed stents. This comprehensive review will assist practicing interventional cardiologists in understanding the technical aspects of OCT based upon the physics of light and will also highlight the emerging research and clinical applications of OCT. Semi-automated imaging analyses of OCT systems permit accurate measurements of luminal architecture and provide insights regarding stent apposition, overlap, neointimal thickening, and, in the case of bioabsorbable stents, information regarding the time course of stent dissolution. The advantages and limitations of this new imaging modality will be discussed with emphasis on key physical and technical aspects of intracoronary image acquisition, current applications, definitions, pitfalls, and future directions.

Entities:  

Mesh:

Year:  2009        PMID: 19926041      PMCID: PMC4113036          DOI: 10.1016/j.jcin.2009.06.019

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  40 in total

Review 1.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

2.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods.

Authors:  Patrick W Serruys; John A Ormiston; Yoshinobu Onuma; Evelyn Regar; Nieves Gonzalo; Hector M Garcia-Garcia; Koen Nieman; Nico Bruining; Cécile Dorange; Karine Miquel-Hébert; Susan Veldhof; Mark Webster; Leif Thuesen; Dariusz Dudek
Journal:  Lancet       Date:  2009-03-14       Impact factor: 79.321

Review 3.  Current and future developments in intracoronary optical coherence tomography imaging.

Authors:  Peter Barlis; Joseph M Schmitt
Journal:  EuroIntervention       Date:  2009-01       Impact factor: 6.534

4.  A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography.

Authors:  Hui Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Opt Commun       Date:  2008-04-01       Impact factor: 2.310

5.  Coronary risk factors and plaque morphology in men with coronary disease who died suddenly.

Authors:  A P Burke; A Farb; G T Malcom; Y H Liang; J Smialek; R Virmani
Journal:  N Engl J Med       Date:  1997-05-01       Impact factor: 91.245

6.  Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy.

Authors:  Takashi Kubo; Toshio Imanishi; Shigeho Takarada; Akio Kuroi; Satoshi Ueno; Takashi Yamano; Takashi Tanimoto; Yoshiki Matsuo; Takashi Masho; Hironori Kitabata; Kazushi Tsuda; Yoshiaki Tomobuchi; Takashi Akasaka
Journal:  J Am Coll Cardiol       Date:  2007-08-20       Impact factor: 24.094

7.  Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease.

Authors:  Briain D MacNeill; Ik-Kyung Jang; Brett E Bouma; Nicusor Iftimia; Masamichi Takano; Hiroshi Yabushita; Milen Shishkov; Christopher R Kauffman; Stuart L Houser; H Thomas Aretz; Denise DeJoseph; Elkan F Halpern; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2004-09-01       Impact factor: 24.094

Review 8.  Coronary plaque erosion without rupture into a lipid core. A frequent cause of coronary thrombosis in sudden coronary death.

Authors:  A Farb; A P Burke; A L Tang; T Y Liang; P Mannan; J Smialek; R Virmani
Journal:  Circulation       Date:  1996-04-01       Impact factor: 29.690

9.  Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study.

Authors:  Takashi Kubo; Toshio Imanishi; Hironori Kitabata; Akio Kuroi; Satoshi Ueno; Takashi Yamano; Takashi Tanimoto; Yoshiki Matsuo; Takashi Masho; Shigeho Takarada; Atsushi Tanaka; Nobuo Nakamura; Masato Mizukoshi; Yoshiaki Tomobuchi; Takashi Akasaka
Journal:  JACC Cardiovasc Imaging       Date:  2008-07

10.  Various types of plaque disruption in culprit coronary artery visualized by optical coherence tomography in a patient with unstable angina.

Authors:  Takashi Tanimoto; Toshio Imanishi; Atsushi Tanaka; Takashi Yamano; Hironori Kitabata; Shigeho Takarada; Takashi Kubo; Nobuo Nakamura; Kumiko Hirata; Masato Mizukoshi; Takashi Akasaka
Journal:  Circ J       Date:  2008-11-11       Impact factor: 2.993

View more
  164 in total

1.  Contemporary assessment of stent strut coverage by OCT.

Authors:  Guilherme F Attizzani; Hiram G Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-26       Impact factor: 2.357

2.  Treatment of a large thrombus containing lesion with the MGuard protective net coronary stent system: optical coherence tomographic evidence of complete plaque sealing.

Authors:  Alessio La Manna; Salvatore Davide Tomasello; Corrado Tamburino
Journal:  Clin Res Cardiol       Date:  2010-06-30       Impact factor: 5.460

3.  Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions.

Authors:  Edouard Gerbaud; Giora Weisz; Atsushi Tanaka; Manabu Kashiwagi; Takehisa Shimizu; Lin Wang; Christiano Souza; Brett E Bouma; Melissa J Suter; Milen Shishkov; Giovanni J Ughi; Elkan F Halpern; Mireille Rosenberg; Sergio Waxman; Jeffrey W Moses; Gary S Mintz; Akiko Maehara; Guillermo J Tearney
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-15       Impact factor: 6.875

Review 4.  Methods and algorithms for optical coherence tomography-based angiography: a review and comparison.

Authors:  Anqi Zhang; Qinqin Zhang; Chieh-Li Chen; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

5.  Optical coherence tomography: Translation from 3D-printed vascular models of the anterior cerebral circulation to the first human images of implanted surface modified flow diverters.

Authors:  Mario Martínez-Galdámez; Jorge Escartín; Boris Pabón; Carlos Diaz; Roberto Martín-Reyes; Antonio Hermosín; Eduardo Crespo; Claudio Rodríguez; Gonzalo Monedero; Krishna Joshi; Demetrius K Lopes
Journal:  Interv Neuroradiol       Date:  2018-11-05       Impact factor: 1.610

6.  Intravascular optical coherence tomography measurement of size and apposition of metallic stents.

Authors:  Sahar Elahi; Marc D Feldman; Jouke Dijkstra; Thomas E Milner
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

Review 7.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

8.  Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage.

Authors:  G J Ughi; T Adriaenssens; K Onsea; P Kayaert; C Dubois; P Sinnaeve; M Coosemans; W Desmet; J D'hooge
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

Review 9.  Intravascular imaging tools in the cardiac catheterization laboratory: comprehensive assessment of anatomy and physiology.

Authors:  Parham Eshtehardi; Jennifer Luke; Michael C McDaniel; Habib Samady
Journal:  J Cardiovasc Transl Res       Date:  2011-04-01       Impact factor: 4.132

10.  Erosion/malapposition of a sirolimus eluting stent - optical coherence tomography image - a case report.

Authors:  G Sengottuvelu
Journal:  Indian Heart J       Date:  2012-11-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.