| Literature DB >> 25544842 |
Mamta Kaushik1, Roshni Sharma1, Pallavi Reddy1, Pallavi Pathak1, Pooja Udameshi1, Narmatha Vallakuruchi Jayabal1.
Abstract
This in vitro study evaluated the presence of voids in powder-liquid and capsulated glass ionomer cement. 40 cavities were prepared on root surfaces of maxillary incisors and divided into four groups. Cavities were conditioned with glass ionomer cement liquid (GC Corporation, Tokyo, Japan) in Groups 1 and 3 and with dentin conditioner (GC Corporation, Tokyo, Japan) in Groups 2 and 4. Conventional powder-liquid glass ionomer cement (GC Fuji II, GC Corporation, Tokyo, Japan) was used as a restorative material in Groups 1 and 2. Capsulated glass ionomer cement (GC Fuji II, GC Corporation, Tokyo, Japan) was used in Groups 3 and 4. Samples were sectioned and viewed under stereomicroscope to check for the presence of voids within the cement and at the cement-tooth junction. Data was analyzed using one-way ANOVA and Tukey's post hoc tests. Group 4 showed statistically significant results (P < 0.05) when compared to Groups 1 and 2 for voids within the cement. However, for voids at the margins, the results were statistically insignificant.Entities:
Year: 2014 PMID: 25544842 PMCID: PMC4269314 DOI: 10.1155/2014/935240
Source DB: PubMed Journal: Int J Biomater ISSN: 1687-8787
Figure 1Distribution of samples.
Figure 2Procedure.
Materials, composition, and manufacture.
| Materials employed | Composition | Manufacturer |
|---|---|---|
| GC Fuji II Universal Restorative | Powder: 95% fluoroaluminosilicate glass (amorphous) | G.C. Corporation, Tokyo, Japan |
| Liquid: 50% distilled water | ||
|
| ||
| GC Fuji II Capsule | Powder/liquid ratio (g/g) 0.30/0.11 | G.C. Corporation, Tokyo, Japan |
|
| ||
| GC Fuji II Universal Restorative Liquid | 50% distilled water | G.C. Corporation, Tokyo, Japan |
|
| ||
| GC Dentin Conditioner | 10% polyacrylic acid | G.C. Corporation, Tokyo, Japan |
Figure 3Results.
Mean values for voids within the cement.
| Groups | Mean | Standard deviation | Decision* |
|---|---|---|---|
| Group 1 | 7.08 | 2.87 | a |
| Group 2 | 7.35 | 2.74 | a |
| Group 3 | 10.39 | 5.16 | b |
| Group 4 | 13.23 | 3.83 | b |
*Different letters indicate statistically significant differences between groups (P < 0.05).
Mean values for voids at the margins (μm).
| Groups | Mean | Standard deviation | Decision* |
|---|---|---|---|
| Group 1 | 12 | 26.99 | a |
| Group 2 | 16 | 50.59 | a |
| Group 3 | 14 | 44.27 | a |
| Group 4 | 12 | 37.97 | a |
*Different letters indicate statistically significant differences between groups (P < 0.05).
Results of Tukey's post hoc test.
| Dependent variable | Group | Group | Mean difference | Significance |
|---|---|---|---|---|
| Voids within cement | 4 | 3 | 2.84 | 0.349 |
| 2 | 5.88 | 0.007* | ||
| 1 | 6.15 | 0.005* | ||
| 3 | 2 | 3.04 | 0.291 | |
| 1 | 3.31 | 0.223 | ||
| 2 | 1 | 0.27 | 0.999 |
Values marked with *indicate statistically significant differences.