Literature DB >> 25539272

Tube potential and CT radiation dose optimization.

Diego Lira1, Atul Padole, Mannudeep K Kalra, Sarabjeet Singh.   

Abstract

OBJECTIVE: This article describes tube potential and its effect on image quality and radiation dose for CT in different body regions and clinical indications.
CONCLUSION: Tube potential is an important scanning parameter for radiation dose optimization. Reduction of tube potential results in increased image contrast of iodine-enhanced CT as well as increased image noise.

Entities:  

Keywords:  image quality; radiation dose; tube potential

Mesh:

Year:  2015        PMID: 25539272     DOI: 10.2214/AJR.14.13281

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Ultra-low-dose multiphase CT angiography derived from CT perfusion data in patients with middle cerebral artery stenosis.

Authors:  Xiaoling Wu; Yuelong Yang; Menghuang Wen; Lijuan Wang; Yunjun Yang; Yuhu Zhang; Zihua Mo; Kun Nie; Biao Huang
Journal:  Neuroradiology       Date:  2019-10-30       Impact factor: 2.804

Review 2.  What a difference a delay makes! CT urogram: a pictorial essay.

Authors:  Abraham Noorbakhsh; Lejla Aganovic; Noushin Vahdat; Soudabeh Fazeli; Romy Chung; Fiona Cassidy
Journal:  Abdom Radiol (NY)       Date:  2019-12

3.  Optimization of tube voltage in X-ray dark-field chest radiography.

Authors:  Andreas P Sauter; Jana Andrejewski; Fabio De Marco; Konstantin Willer; Lukas B Gromann; Wolfgang Noichl; Fabian Kriner; Florian Fischer; Christian Braun; Thomas Koehler; Felix Meurer; Alexander A Fingerle; Daniela Pfeiffer; Ernst Rummeny; Julia Herzen; Franz Pfeiffer
Journal:  Sci Rep       Date:  2019-06-18       Impact factor: 4.379

4.  Feasibility Study of Dose Modulation for Reducing Radiation Dose with Arms-Down Patient Position in Abdominal Computed Tomography.

Authors:  Jina Shim; Yong Eun Chung; Hyun-Woo Jeong; Youngjin Lee
Journal:  Diagnostics (Basel)       Date:  2022-01-27

5.  Dose Reduction of Dynamic Computed Tomography Myocardial Perfusion Imaging by Tube Voltage Change: Investigation in a Swine Model.

Authors:  Wenlei Geng; Yang Gao; Na Zhao; Hankun Yan; Wei Ma; Yunqiang An; Liujun Jia; Bin Lu
Journal:  Front Cardiovasc Med       Date:  2022-03-03

6.  Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn's disease patients.

Authors:  Yeoun Joo Lee; Jae-Yeon Hwang; Hwaseong Ryu; Tae Un Kim; Yong-Woo Kim; Jae Hong Park; Ki Seok Choo; Kyung Jin Nam; Jieun Roh
Journal:  Sci Rep       Date:  2022-02-09       Impact factor: 4.379

7.  Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels.

Authors:  Hye Ji; Sun Kyoung You; Jeong Eun Lee; So Mi Lee; Hyun-Hae Cho; Joon Young Ohm
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-08-27

8.  A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study.

Authors:  Wei Zhou; Gregory J Michalak; Jayse M Weaver; Hao Gong; Lifeng Yu; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2020-04       Impact factor: 10.065

  8 in total