Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE).

Ana-Maria Simundic, Stephen Church, Michael P Cornes, Kjell Grankvist, Giuseppe Lippi, Mads Nybo, Nora Nikolac, Edmee van Dongen-Lases, Pinar Eker, Svjetlana Kovalevskaya, Gunn B B Kristensen, Ludek Sprongl, Zorica Sumarac.   

Abstract

BACKGROUND: An observational study was conducted in 12 European countries by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) to assess the level of compliance with the CLSI H3-A6 guidelines.
METHODS: A structured checklist including 29 items was created to assess the compliance of European phlebotomy procedures with the CLSI H3-A6 guideline. A risk occurrence chart of individual phlebotomy steps was created from the observed error frequency and severity of harm of each guideline key issue. The severity of errors occurring during phlebotomy was graded using the risk occurrence chart.
RESULTS: Twelve European countries participated with a median of 33 (18-36) audits per country, and a total of 336 audits. The median error rate for the total phlebotomy procedure was 26.9 % (10.6-43.8), indicating a low overall compliance with the recommended CLSI guideline. Patient identification and test tube labelling were identified as the key guideline issues with the highest combination of probability and potential risk of harm. Administrative staff did not adhere to patient identification procedures during phlebotomy, whereas physicians did not adhere to test tube labelling policy.
CONCLUSIONS: The level of compliance of phlebotomy procedures with the CLSI H3-A6 guidelines in 12 European countries was found to be unacceptably low. The most critical steps in need of immediate attention in the investigated countries are patient identification and tube labelling.

Entities:  

Mesh:

Year:  2015        PMID: 25536667     DOI: 10.1515/cclm-2014-1053

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  21 in total

1.  Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults.

Authors:  Lisa A Spacek; Matthew Mudalel; Frank Tittel; Terence H Risby; Steven F Solga
Journal:  J Breath Res       Date:  2015-12-14       Impact factor: 3.262

2.  Analysis of preanalytical errors in a clinical chemistry laboratory: A 2-year study.

Authors:  Jerold C Alcantara; Bandar Alharbi; Yasser Almotairi; Mohammad Jahoor Alam; Abdel Rahim Mahmoud Muddathir; Khalid Alshaghdali
Journal:  Medicine (Baltimore)       Date:  2022-07-08       Impact factor: 1.817

3.  The results of a close follow-up of trainees to gain a good blood collection practice.

Authors:  Güzin Aykal; Hatice Esen; Ayşenur Yeğin; Cemile Öz
Journal:  J Med Biochem       Date:  2020-09-02       Impact factor: 3.402

4.  Male mosquitoes as vehicles for insecticide.

Authors:  James W Mains; Corey L Brelsfoard; Stephen L Dobson
Journal:  PLoS Negl Trop Dis       Date:  2015-01-15

5.  Continuous quality control of the blood sampling procedure using a structured observation scheme.

Authors:  Tine Lindberg Seemann; Mads Nybo
Journal:  Biochem Med (Zagreb)       Date:  2016-10-15       Impact factor: 2.313

Review 6.  Phlebotomy, a bridge between laboratory and patient.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

7.  Nurses' knowledge on phlebotomy in tertiary hospitals in China: a cross-sectional multicentric survey.

Authors:  Qian Cai; Yunxian Zhou; Dangan Yang
Journal:  Biochem Med (Zagreb)       Date:  2017-11-24       Impact factor: 2.313

8.  [Which patient needs controls of laboratory values after elective laparoscopic cholecystectomy?-Can a score help?]

Authors:  L Fischer; G Kolb; C Segendorf; B Huber; K Watrinet; L Horoba; B Huck; D Schultze
Journal:  Chirurg       Date:  2021-04       Impact factor: 0.955

9.  Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals.

Authors:  Dragana Milutinović; Ilija Andrijević; Milijana Ličina; Ljiljana Andrijević
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

10.  How compliant are technicians with universal safety measures in medical laboratories in Croatia?--A pilot study.

Authors:  Kristina Dukic; Matea Zoric; Petra Pozaic; Jelena Starcic; Marija Culjak; Andrea Saracevic; Marijana Miler
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.