| Literature DB >> 26527124 |
Dragana Milutinović1, Ilija Andrijević2, Milijana Ličina1, Ljiljana Andrijević3.
Abstract
INTRODUCTION: This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis.Entities:
Keywords: hemolysis; medical staff; patient safety; phlebotomy; preanalytical phase; questionnaire
Mesh:
Year: 2015 PMID: 26527124 PMCID: PMC4622195 DOI: 10.11613/BM.2015.040
Source DB: PubMed Journal: Biochem Med (Zagreb) ISSN: 1330-0962 Impact factor: 2.313
Figure 1Healthcare staff confidence level at first and last performed venipuncture.
Confidence level at first and last venipuncture in relation to profile of healthcare staff.
| First venipuncture | Last venipuncture | ||
| Nurses | 44/94 | 2.4 ± 1.3 | 4.9 ± 0.3 |
| Laboratory technicians | 50/94 | 2.7 ± 1.1 | 4.7 ± 0.6 |
| A five-point Likert scale from 1 to 5 was used for level of confidence evaluation, ranging from 1 - unconfident, 2 - less confident, 3 - neither confident nor unconfident, 4 - confident, and 5 - more confident. | |||
Knowledge of possible factors affecting hemolysis in vitro due to materials used in venipuncture.
| Syringe and needle | 46 | 0.49 |
| Cannula and syringe | 30 | 0.32 |
| Cannula and evacuated tube* | 11 | 0.11* |
| Evacuated tube and needle | 7 | 0.8 |
| Less than or equal to one minute | 3 | 0.03 |
| More than a minute * | 91 | 0.97* |
| Less than 18G | 39 | 0.41 |
| 20−22G | 2 | 0.02 |
| More than 22G* | 27 | 0.29* |
| None of the proposed | 26 | 0.28 |
| Forcing blood through a needle on a syringe* | 75 | 0.80* |
| Withdrawing the needle and pouring the blood from the syringe | 14 | 0.15 |
| A blood sample flows freely into the tube | 5 | 0.05 |
| *Correct answers. | ||
Knowledge of factors that can potentially affect hemolysis in vitro including venipuncture technique and blood specimen handling.
| Turbulent* | 78 | 0.83* | |
| Laminar | 16 | 0.17 | |
| Antecubital fossa (elbow pit) | 13 | 0.14 | |
| Distal to the antecubital fossa (elbow pit)* | 81 | 0.86* | |
| One attempt | 5 | 0.05 | |
| More than one attempt* | 89 | 0.95* | |
| Yes | 39 | 0.42 | |
| No* | 55 | 0.59* | |
| In the area above the hematoma | 71 | 0.76 | |
| In the area below the hematoma* | 23 | 0.25* | |
| Full-draw tube | 15 | 0.16 | |
| Half-filled greater than or equal half | 3 | 0.03 | |
| Less than half filled tube* | 76 | 0.81* | |
| Specimen should not be mixed with anticoagulants | 16 | 0.17 | |
| Specimen should be inverted 5-10 times for proper mixing of the anticoagulant | 5 | 0.05 | |
| Specimen should be mixed with anticoagulants by strongly shaking the tube holding it in horizontal position* | 73 | 0.78* | |
| *Correct answers. | |||
Average score values of knowledge test compared to the length of service, frequency in conducting venipuncture and confidence level at the last venipuncture.
| up to 5 years | 24 | 7.3 | 0.581 |
| from 5 to 10 years | 29 | 7.8 | |
| from 10 to 19 years | 22 | 7.9 | |
| more than 19 years | 19 | 7.8 | |
| On daily basis | 58 | 7.9 | 0.095 |
| Several times a week | 15 | 7.9 | |
| Several times a month | 21 | 7.1 | |
| Unconfident | -- | -- | 0.551 |
| Neither confident nor unconfident | 4 | 7.3 | |
| Confident | 90 | 7.8 | |
| N - Number of participants | |||