Literature DB >> 25535784

Influence of Etching Protocol and Silane Treatment with a Universal Adhesive on Lithium Disilicate Bond Strength.

V K Kalavacharla, N C Lawson, L C Ramp, J O Burgess.   

Abstract

OBJECTIVES: To measure the effects of hydrofluoric acid (HF) etching and silane prior to the application of a universal adhesive on the bond strength between lithium disilicate and a resin. METHODS AND MATERIALS: Sixty blocks of lithium disilicate (e.max CAD, Ivoclar Vivadent) were sectioned into coupons and polished. Specimens were divided into six groups (n=10) based on surface pretreatments, as follows: 1) no treatment (control); 2) 5% HF etch for 20 seconds (5HF); 3) 9.5% HF etch for 60 seconds (9.5HF); 4) silane with no HF (S); 5) 5% HF for 20 seconds + silane (5HFS); and 6) 9.5% HF for 60 seconds + silane (9.5HFS). All etching was followed by rinsing, and all silane was applied in one coat for 20 seconds and then dried. The universal adhesive (Scotchbond Universal, 3M ESPE) was applied onto the pretreated ceramic surface, air thinned, and light cured for 10 seconds. A 1.5-mm-diameter plastic tube filled with Z100 composite (3M ESPE) was applied over the bonded ceramic surface and light cured for 20 seconds on all four sides. The specimens were thermocycled for 10,000 cycles (5°C-50°C/15 s dwell time). Specimens were loaded until failure using a universal testing machine at a crosshead speed of 1 mm/min. The peak failure load was used to calculate the shear bond strength. Scanning electron microscopy images were taken of representative e.max specimens from each group.
RESULTS: A two-way analysis of variance (ANOVA) determined that there were significant differences between HF etching, silane treatment, and the interaction between HF and silane treatment (p<0.01). Silane treatment provided higher shear bond strength regardless of the use or concentration of the HF etchant. Individual one-way ANOVA and Tukey post hoc analyses were performed for each silane group. Shear bond strength values for each etch time were significantly different (p<0.01) and could be divided into significantly different groups based on silane treatment: no silane treatment: 0 HF < 5% HF < 9.5% HF; and RelyX silane treatment: 0 HF < 5% HF and 9.5% HF.
CONCLUSIONS: Both HF and silane treatment significantly improved the bond strength between resin and lithium disilicate when used with a universal adhesive.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25535784     DOI: 10.2341/14-116-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  21 in total

1.  Adhesion of multimode adhesives to enamel and dentin after one year of water storage.

Authors:  Paulo Moreira Vermelho; André Figueiredo Reis; Glaucia Maria Bovi Ambrosano; Marcelo Giannini
Journal:  Clin Oral Investig       Date:  2016-10-07       Impact factor: 3.573

2.  Bonding of Clear Aligner Composite Attachments to Ceramic Materials: An In Vitro Study.

Authors:  Bashair A Alsaud; Maher S Hajjaj; Ahmad I Masoud; Ensanya A Abou Neel; Dalia A Abuelenain; Amal I Linjawi
Journal:  Materials (Basel)       Date:  2022-06-10       Impact factor: 3.748

3.  Effect of surface treatment with laser on repair bond strength of composite resin to ceramic.

Authors:  Nazanin Kiomarsi; Azin Jarrah; Nasim Chiniforoush; Sedighe Sadat Hashemikamangar; Mohammad Javad Kharazifard
Journal:  Dent Res J (Isfahan)       Date:  2022-03-21

4.  Bonding of the silane containing multi-mode universal adhesive for lithium disilicate ceramics.

Authors:  Hyun-Young Lee; Geum-Jun Han; Juhea Chang; Ho-Hyun Son
Journal:  Restor Dent Endod       Date:  2017-01-25

5.  The effect of surface treatment with a fractional carbon dioxide laser on shear bond strength of resin cement to a lithium disilicate-based ceramic.

Authors:  Farzaneh Ahrari; Alireza Boruziniat; Hamideh Sadat Mohammadipour; Mehrnoosh Alirezaei
Journal:  Dent Res J (Isfahan)       Date:  2017 May-Jun

6.  Fracture Resistance of Ceramic Laminate Veneers Bonded to Teeth with Class V Composite Fillings after Cyclic Loading.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Vanya Rasaei; Mohammad J Kharazi Fard
Journal:  Int J Dent       Date:  2018-04-17

7.  HF etching of CAD/CAM materials: influence of HF concentration and etching time on shear bond strength.

Authors:  Antonio Straface; Lena Rupp; Aiste Gintaute; Jens Fischer; Nicola U Zitzmann; Nadja Rohr
Journal:  Head Face Med       Date:  2019-08-08       Impact factor: 2.151

Review 8.  Current perspectives on dental adhesion: (1) Dentin adhesion - not there yet.

Authors:  Jorge Perdigão
Journal:  Jpn Dent Sci Rev       Date:  2020-09-23

9.  Performance of universal adhesives on bonding to leucite-reinforced ceramic.

Authors:  Ryan Jin-Young Kim; Jung-Soo Woo; In-Bog Lee; Young-Ah Yi; Ji-Yun Hwang; Deog-Gyu Seo
Journal:  Biomater Res       Date:  2015-05-22

10.  Analysis of Self-Adhesive Resin Cement Microshear Bond Strength on Leucite-Reinforced Glass-Ceramic with/without Pure Silane Primer or Universal Adhesive Surface Treatment.

Authors:  Yoon Lee; Jae-Hoon Kim; Jung-Soo Woo; Young-Ah Yi; Ji-Yun Hwang; Deog-Gyu Seo
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411