| Literature DB >> 25525510 |
Yusuf Yildirim1, Onur Olcucu1, Alper Agca1, Cengiz Alagoz1, Ali Demircan1, Abdurrahman Basci1, Ahmet Demirok2, Zekayi Kutlubay3.
Abstract
Purpose. We report the effect of isotretinoin on corneal topography, corneal thickness, and biomechanical parameters in patients with acne vulgaris. Method. Fifty-four eyes of 54 patients who received oral isotretinoin for treatment of acne vulgaris were evaluated. All patients underwent a corneal topographical evaluation with a Scheimpflug camera combined with Placido-disk (Sirius), ultrasonic pachymetry measurements, and corneal biomechanical evaluation with an ocular response analyzer at baseline, in the 1st, 3rd, and 6th months of treatment, and 6 months after isotretinoin discontinuation. Results. The thinnest corneal thickness measured with Sirius differed significantly in the 1st, 3rd, and 6th months compared with the baseline measurement; there was no significant change in ultrasonic central corneal thickness measurements and biomechanical parameters (corneal hysteresis and corneal resistance factor) throughout the study. Average simulated keratometry and surface asymmetry index increased significantly only in the first month of treatment according to the baseline. All changes disappeared 6 months after the end of treatment. Conclusion. Basal tear secretion and corneal morphologic properties were significantly influenced during the systemic isotretinoin treatment and the changes were reversible after discontinuation. No statistical important biomechanical differences were found to be induced by isotretinoin.Entities:
Year: 2014 PMID: 25525510 PMCID: PMC4265706 DOI: 10.1155/2014/701361
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Changes of Schirmer 1 test, anesthetized Schirmer test, and tear break-up time of the patients.
| Baseline | 1 month | 3 months | 6 months | Follow-up | |
|---|---|---|---|---|---|
| S1T, mm/5 min | |||||
| Mean ± SD | 28.80 ± 2.40 | 27.60 ± 2.35 | 26.88 ± 2.08 | 26.32 ± 1.96 | 28.78 ± 2.38 |
|
| 0.132 | 0.116 | 0.094 | 0.854 | |
| AST, mm/5 min | |||||
| Mean ± SD | 18.74 ± 3.42 | 16.96 ± 3.30 | 15.06 ± 3.13 | 14.92 ± 3.22 | 18.72 ± 3.40 |
|
| 0.044∤ | 0.021∤ | 0.008∤ | 0.564 | |
| TBUT, sn | |||||
| Mean ± SD | 14.84 ± 2.11 | 10.44 ± 2.82 | 9.86 ± 2.92 | 9.42 ± 3.11 | 14.76 ± 2.26 |
|
| 0.012∤ | 0.008∤ | 0.006∤ | 0.342 |
P a, P value according to paired t-test compared with baseline.
S1T, Schirmer 1 test; AST, anesthetized Schirmer test; TBUT, tear break-up time; SD, standard deviation.
∤Statistically significant at the 0.05 level.
Corneal topographical parameters measured with Sirius before and after treatment.
| Baseline | 1 month | 3 months | 6 months | Follow-up | |
|---|---|---|---|---|---|
| Average SimK, D | |||||
| Mean ± SD | 43.68 ± 1.38 | 43.73 ± 1.35 | 43.62 ± 1.37 | 43.58 ± 1.38 | 43.66 ± 1.38 |
|
| 0.030∤ | 0.322 | 0.462 | 0.564 | |
| SAI | |||||
| Mean ± SD | 0.39 ± 0.31 | 0.45 ± 0.33 | 0.44 ± 0.32 | 0.42 ± 0.33 | 0.40 ± 0.30 |
|
| 0.015∤ | 0.052 | 0.060 | 0.124 | |
| Thinnest CT, | |||||
| Mean ± SD | 539.51 ± 48.33 | 537.13 ± 46.77 | 535.66 ± 46.31 | 534.87 ± 46.23 | 539.46 ± 48.36 |
|
| 0.014∤ | 0.011∤ | 0.005∤ | 0.128 |
P a, P value according to paired t-test compared with baseline.
SimK, simulated keratometry; SAI, surface asymmetry index; CT, corneal thickness; SD, standard deviation.
∤Statistically significant at 0.05 level.
Biomechanical parameters measured with ocular response analyzer and central corneal thickness measured with ultrasonic pachymeter before and after treatment.
| Baseline | 1 month | 3 months | 6 months | Follow-up | |
|---|---|---|---|---|---|
| CH, mmHg | |||||
| Mean ± SD | 11.67 ± 2.22 | 11.48 ± 2.13 | 11.50 ± 2.12 | 11.51 ± 2.13 | 11.58 ± 2.18 |
|
| 0.206 | 0.289 | 0.343 | 0.664 | |
| CRF, mmHg | |||||
| Mean ± SD | 11.11 ± 2.33 | 11.05 ± 2.15 | 11.43 ± 2.14 | 10.97 ± 2.08 | 10.86 ± 2.04 |
|
| 0.691 | 0.644 | 0.535 | 0.489 | |
| CCTusg, | |||||
| Mean ± SD | 544.56 ± 46.14 | 542.18 ± 45.92 | 540.72 ± 45.94 | 539.89 ± 45.88 | 544.53 ± 46.08 |
|
| 0.547 | 0.322 | 0.208 | 0.782 |
P a, P value according to paired t-test compared with baseline.
CH, corneal hysteresis; CRF, corneal resistance factor; CCTusg, central corneal thickness measured with ultrasonic pachymeter; SD, standard deviation.