Literature DB >> 25523588

Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms.

R Irie1, M Suzuki2, M Yamamoto3, N Takano2, Y Suga3, M Hori2, K Kamagata2, M Takayama2, M Yoshida2, S Sato2, N Hamasaki2, H Oishi4, S Aoki2.   

Abstract

BACKGROUND AND
PURPOSE: Blood flow in an intracranial stent cannot be visualized with 3D time-of-flight MR angiography owing to magnetic susceptibility and radiofrequency shielding. As a novel follow-up tool after stent-assisted coil embolization, we applied MRA by using a Silent Scan algorithm that contains an ultrashort TE combined with an arterial spin-labeling technique (Silent MRA). The purpose of this study was to determine whether Silent MRA could visualize flow in an intracranial stent placed in the anterior circulation.
MATERIALS AND METHODS: Nine patients treated with stent-assisted coil embolization for anterior circulation aneurysms underwent MRAs (Silent MRA and TOF MRA) and x-ray digital subtraction angiography. MRAs were performed in the same session on a 3T unit. Two neuroradiologists independently reviewed the MRA images and subjectively scored flow in a stent as 1 (not visible) to 4 (excellent) by referring to the latest x-ray digital subtraction angiography image as a criterion standard.
RESULTS: Both observers gave MRA higher scores than TOF MRA for flow in a stent in all cases. The mean score for Silent MRA was 3.44 ± 0.53, and for TOF MRA, it was 1.44 ± 0.46 (P < .001).
CONCLUSIONS: Silent MRA was able to visualize flow in an intracranial stent more effectively than TOF MRA. Silent MRA might be useful for follow-up imaging after stent-assisted coil embolization, though these study results may be only preliminary due to some limitations.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25523588      PMCID: PMC7990590          DOI: 10.3174/ajnr.A4199

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  18 in total

1.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

2.  Intracranial aneurysms treated with coil placement: test characteristics of follow-up MR angiography--multicenter study.

Authors:  Joanna D Schaafsma; Birgitta K Velthuis; Charles B L M Majoie; René van den Berg; Patrick A Brouwer; Frederik Barkhof; Omid Eshghi; Gerard A P de Kort; Rob T H Lo; Theo D Witkamp; Marieke E S Sprengers; Marianne A van Walderveen; Joseph C Bot; Esther Sanchez; W Peter Vandertop; Jan van Gijn; Erik Buskens; Yolanda van der Graaf; Gabriël J E Rinkel
Journal:  Radiology       Date:  2010-05-26       Impact factor: 11.105

3.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

4.  International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial.

Authors:  Andrew Molyneux; Richard Kerr; Irene Stratton; Peter Sandercock; Mike Clarke; Julia Shrimpton; Rury Holman
Journal:  Lancet       Date:  2002-10-26       Impact factor: 79.321

5.  Delayed thrombosis or stenosis following enterprise-assisted stent-coiling: is it safe? Midterm results of the interstate collaboration of enterprise stent coiling.

Authors:  J Mocco; Kyle M Fargen; Felipe C Albuquerque; Bernard R Bendok; Alan S Boulos; Jeffrey S Carpenter; David J Fiorella; Brian L Hoh; Jay U Howington; Kenneth M Liebman; Sabareesh K Natarajan; Ansaar T Rai; Rafael Rodriguez-Mercado; Adnan H Siddiqui; Kenneth V Snyder; Erol Veznedaroglu; L Nelson Hopkins; Elad I Levy
Journal:  Neurosurgery       Date:  2011-10       Impact factor: 4.654

6.  Residual flow after cerebral aneurysm coil occlusion: diagnostic accuracy of MR angiography.

Authors:  Pascale Lavoie; Jean-Luc Gariépy; Geneviève Milot; Steve Jodoin; Fernand Bédard; Francois Trottier; René Verreault
Journal:  Stroke       Date:  2012-01-19       Impact factor: 7.914

7.  Usefulness of contrast-enhanced magnetic resonance angiography for follow-up of coil embolization with the enterprise stent for cerebral aneurysms.

Authors:  Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  J Comput Assist Tomogr       Date:  2011 Sep-Oct       Impact factor: 1.826

8.  The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms.

Authors:  Won-Sang Cho; Sam Soo Kim; Seung Jin Lee; Sung Hun Kim
Journal:  Acta Radiol       Date:  2013-09-03       Impact factor: 1.990

9.  Stent-assisted coiling of unruptured intracranial aneurysms: long-term follow-up in 164 patients with 183 aneurysms.

Authors:  Benjamin Mine; Ali Aljishi; Jean-Bernard D'Harcour; Denis Brisbois; Laurent Collignon; Boris Lubicz
Journal:  J Neuroradiol       Date:  2014-01-23       Impact factor: 3.447

10.  Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images.

Authors:  Young Dae Cho; Kang Min Kim; Woong Jae Lee; Chul-Ho Sohn; Hyun-Seung Kang; Jeong Eun Kim; Moon Hee Han
Journal:  Korean J Radiol       Date:  2014-01-08       Impact factor: 3.500

View more
  25 in total

Review 1.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

2.  Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device.

Authors:  C Timsit; S Soize; A Benaissa; C Portefaix; J-Y Gauvrit; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-21       Impact factor: 3.825

3.  Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study.

Authors:  Song'an Shang; Jing Ye; Xianfu Luo; Jianxun Qu; Yong Zhen; Jingtao Wu
Journal:  Eur Radiol       Date:  2017-04-05       Impact factor: 5.315

4.  Validation of Zero TE-MRA in the Characterization of Cerebrovascular Diseases: A Feasibility Study.

Authors:  S Shang; J Ye; W Dou; X Luo; J Qu; Q Zhu; H Zhang; J Wu
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

5.  Visualization of Aneurysmal Neck and Dome after Coiling with 3D Multifusion Imaging of Silent MRA and FSE-MR Cisternography.

Authors:  T Satoh; T Hishikawa; M Hiramatsu; K Sugiu; I Date
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-04       Impact factor: 3.825

6.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

7.  Improvement in visualization of carotid artery uniformity using silent magnetic resonance angiography.

Authors:  Yasuhiro Fujiwara; Yoshiyuki Muranaka
Journal:  Radiol Phys Technol       Date:  2016-09-08

8.  Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; N Hamasaki; K Kamagata; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

9.  Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device.

Authors:  H Oishi; T Fujii; M Suzuki; N Takano; K Teranishi; K Yatomi; T Kitamura; M Yamamoto; S Aoki; H Arai
Journal:  AJNR Am J Neuroradiol       Date:  2019-05-02       Impact factor: 3.825

10.  Stent-Assisted Clip Placement for Complex Internal Carotid Artery Intracranial Aneurysms.

Authors:  Adnan I Qureshi; Morad Chughtai; Asif A Khan; M Fareed K Suri; Gregory T Sherr
Journal:  J Vasc Interv Neurol       Date:  2016-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.