Literature DB >> 22267824

Residual flow after cerebral aneurysm coil occlusion: diagnostic accuracy of MR angiography.

Pascale Lavoie1, Jean-Luc Gariépy, Geneviève Milot, Steve Jodoin, Fernand Bédard, Francois Trottier, René Verreault.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of this study was to estimate the performance measures of MR angiography (MRA) in the diagnosis of aneurysm residual flow after coil occlusion.
METHODS: Patients having at least 1 cerebral aneurysm treated with coil occlusion were prospectively and consecutively enrolled. Time of flight and contrast-enhanced MRA were performed the same day of the DSA follow-up. The degree of aneurysm occlusion and dimensions of the residual flow were evaluated by independent readers at MRA and digital subtraction angiogram. MRA performance measures were estimated in a cross-sectional analysis and repeated in subgroups of aneurysm sizes and locations. MRA predictive values for recurrence were also estimated using a longitudinal design.
RESULTS: We obtained 167 aneurysm evaluations for each imaging modality. Class 3 residual flow was seen on digital subtraction angiogram follow-up in 27%. The sensitivity and specificity of MRA was 88% (95% CI, 80-94) and 79% (95% CI, 67-88), respectively. The positive predictive value for a Class 3 recurrence was 67% (95% CI, 51-80) and the negative predictive value was 93% (95% CI, 86-97). Time-of-flight MRA underestimated the length of the residual flow (P=0.039), whereas contrast-enhanced MRA overestimated its width (P<0.0001). MRA sensitivity for a Class 3 residual flow was lower for aneurysms <6 mm (P=0.01).
CONCLUSIONS: MRA has sufficient accuracy for screening of aneurysm residual flow after coil occlusion. Due to its lower negative predictive value, recurrent aneurysms should be confirmed with digital subtraction angiogram before planning a retreatment. Routine use of MRA to follow small aneurysms should wait better estimation of its performance in this particular subgroup.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22267824     DOI: 10.1161/STROKEAHA.111.635300

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  11 in total

Review 1.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

2.  The clinical value of ceMRA versus DSA for follow-up of intracranial aneurysms treated by coil embolization: an assessment of occlusion classifications and impact on treatment decisions.

Authors:  Maximilian Patzig; Robert Forbrig; Margaretha Gruber; Thomas Liebig; Franziska Dorn
Journal:  Eur Radiol       Date:  2020-11-21       Impact factor: 5.315

3.  Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; N Hamasaki; K Kamagata; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

4.  Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms.

Authors:  R Irie; M Suzuki; M Yamamoto; N Takano; Y Suga; M Hori; K Kamagata; M Takayama; M Yoshida; S Sato; N Hamasaki; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

5.  Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms?

Authors:  P Gölitz; T Struffert; I Kaschka; K Roessler; F Knossalla; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-17       Impact factor: 3.825

6.  Late onset aneurysm development following radiosurgical obliteration of a cerebellopontine angle meningioma.

Authors:  Christopher Paul Kellner; Michael M McDowell; E Sander Connolly; Michael B Sisti; Sean D Lavine
Journal:  BMJ Case Rep       Date:  2014-05-14

7.  Magnetic Resonance Imaging in Aneurysmal Subarachnoid Hemorrhage: Current Evidence and Future Directions.

Authors:  Sarah E Nelson; Haris I Sair; Robert D Stevens
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

8.  Usefulness of 3D T1-SPACE in Combination With 3D-TOF MRA for Follow-Up Evaluation of Intracranial Aneurysms Treated With Pipeline Embolization Devices.

Authors:  Qiuji Shao; Qiaowei Wu; Qiang Li; Tianxiao Li; Li Li; Kaitao Chang; Meiyun Wang
Journal:  Front Neurol       Date:  2020-12-11       Impact factor: 4.003

9.  Application of 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm.

Authors:  Qiuji Shao; Qiang Li; Qiaowei Wu; Tianxiao Li; Li Li; Kaitao Chang; Yingkun He
Journal:  J Interv Med       Date:  2021-02-27

10.  Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images.

Authors:  Young Dae Cho; Kang Min Kim; Woong Jae Lee; Chul-Ho Sohn; Hyun-Seung Kang; Jeong Eun Kim; Moon Hee Han
Journal:  Korean J Radiol       Date:  2014-01-08       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.