| Literature DB >> 25506701 |
Youqun Lai1, Liwan Shi1, Qin Lin1, Lirong Fu1, Huiming Ha1.
Abstract
PURPOSE: Flattening filter free (FFF) beams show the potential for a higher dose rate and lower peripheral dose. We investigated the planning study of FFF beams with their role for volumetric modulated arc therapy (VMAT) in squamous cell carcinoma of the scalp. METHODS AND MATERIALS: One patient with squamous cell carcinoma which had involvement of entire scalp was subjected to VMAT using TrueBeam linear accelerator. As it was a rare skin malignancy, CT data of 7 patients with brain tumors were also included in this study, and their entire scalps were outlined as target volumes. Three VMAT plans were employed with RapidArc form: two half-field full-arcs VMAT using 6 MV standard beams (HFF-VMAT-FF), eight half-field quarter-arcs VMAT using 6 MV standard beams (HFQ-VMAT-FF), and HFQ-VMAT using FFF beams (HFQ-VMAT-FFF). Prescribed dose was 25 × 2 Gy (50 Gy). Plan quality and efficiency were assessed for all plans.Entities:
Mesh:
Year: 2014 PMID: 25506701 PMCID: PMC4266613 DOI: 10.1371/journal.pone.0114953
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Delineated planning target volume (PTV) for squamous cell carcinoma of the scalp (A), and two different beam setups in VMAT plans: (B) Two 360° arcs were used with half-field beam. (C) Eight half-field quarter-arcs (90°) were used in VMAT plan.
Figure 2The beam setup of two designs for VMAT plans in clockwise (CW): (A) HFF-VMAT: two half-field full-arcs VMAT; (B) HFQ-VMAT: eight half-field quarter-arcs VMAT.
Dosimetric parameters of PTV for treatment plans created with different planning techniques.
| PTV | HFF-VMAT-FF | HFQ-VMAT-FF | HFQ-VMAT-FFF |
|
| Dmax (Gy) | 55.64±0.63 | 55.57±0.55 | 55.61±0.59 | a = 0.73, b = 0.83 |
| Dmin (Gy) | 41.69±0.45 | 41.75±0.87 | 41.71±0.79 | a = 0.88, b = 0.9 |
| Dmean (Gy) | 51.83±0.29 | 51.86±0.35 | 51.79±0.25 | a = 0.85, b = 0.58 |
| D2% (Gy) | 53.60±0.68 | 53.63±0.74 | 53.62±0.50 | a = 0.88, b = 0.99 |
| D98% (Gy) | 49.33±0.15 | 49.15±0.23 | 49.32±0.21 | a = 0.11, b = 0.23 |
| V95% (%) | 99.82±0.07 | 99.84±0.08 | 99.88±0.05 | a = 0.67, b = 0.31 |
| V110% (%) | 0.0067±0.008 | 0.0037±0.005 | 0.004±0.005 | a = 0.28, b = 0.73 |
| CI | 1.40±0.15 | 1.41±0.14 | 1.42±0.12 | a = 0.35, b = 0.95 |
| HI | 1.066±0.012 | 1.067±0.015 | 1.066±0.010 | a = 0.41, b = 0.47 |
Abbreviations: HFF-VMAT-FF = two half-field full-arcs VMAT with conventional flattened (FF) beam; HFQ-VMAT-FF = eight half-field quarter-arcs VMAT with FF beam; HFQ-VMAT-FFF = eight half-field quarter-arcs VMAT with flattening filter free (FFF) beam; CI = conformity index; HI = homogeneity index.
* P value corresponds to the paired t test: a = HFF-VMAT-FF vs HFQ-VMAT-FF, b = HFQ-VMAT-FF vs HFQ-VMAT-FFF.
Figure 3Isodose distributions for one patient with squamous cell carcinoma in axial, coronal, and sagittal planes.
(A) HFF-VMAT-FF: two half-field full-arcs VMAT with conventional flattened (FF) beam; (B) HFQ-VMAT-FF: eight half-field quarter-arcs VMAT with FF beam; (C) HFQ-VMAT-FFF: eight half-field quarter-arcs VMAT with flattening filter free (FFF) beam.
Figure 4Dose-volume histogram (DVH) comparison for the PTV and brain with different planning techniques: (a) HFF-VMAT-FF: two half-field full-arcs VMAT with conventional flattened (FF) beam; (b) HFQ-VMAT-FF: eight half-field quarter-arcs VMAT with FF beam; (c) HFQ-VMAT-FFF: eight half-field quarter-arcs VMAT with flattening filter free (FFF) beam.
The mean doses of organs at risk, MU, beam-on time, and mean dose rate (MDR) for treatment plans created with different planning techniques.
| Mean dose | HFF-VMAT-FF | HFQ-VMAT-FF | HFQ-VMAT-FFF |
|
| Brain (Gy) | 14.61±3.67 | 12.76±2.66 | 11.82±2.99 | a = 0.01, b = 0.001 |
| Brain stem (Gy) | 2.53±0.32 | 2.11±0.11 | 2.31±0.24 | |
| lens (Gy) | 3.54±0.84 | 3.04±0.27 | 2.88±0.43 | |
| optic nerves (Gy) | 5.68±2.52 | 4.31±1.35 | 4.43±1.36 | |
| optic chiasma (Gy) | 4.26±0.48 | 3.19±0.41 | 3.44±0.47 | |
| Body (Gy) | 19.9±1.99 | 18.59±1.49 | 17.98±1.74 | a = 0.013, b = 0.001 |
| MU | 922±88 | 1019±79 | 1346±130 | a = 0.01, b = 0 |
| Beam-on time (s) | 241 | 243 | 240 | |
| MDR (MU/min) | 459±39 | 502±33 | 673±65 |
Abbreviations: HFF-VMAT-FF = two half-field full-arcs VMAT with conventional flattened (FF) beam; HFQ-VMAT-FF = eight half-field quarter-arcs VMAT with FF beam; HFQ-VMAT-FFF = eight half-field quarter-arcs VMAT with flattening filter free (FFF) beam.
* Body: it is the region of the CT which was scanned.
* P value corresponds to the paired t test: a = HFF-VMAT-FF vs HFQ-VMAT-FF, b = HFQ-VMAT-FF vs HFQ-VMAT-FFF.