Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning.

Y De Deene1, C De Wagter.   

Abstract

In high-precision 3D gel dosimetry, long MR measurement times together with a high amount of RF energy being absorbed by the phantom are very common, and result in a spatially dependent temperature rise in the gel. As T2 of the dosimeter gel is temperature dependent, dose estimation will be affected. In this study we assess the temperature rise in the dosimeter gel by use of MR temperature mapping and computer modelling. It is shown that in conventional MR sequences. where linear k-space sampling is used, a temperature rise of 3 C results in a dose underestimation of 10% over the whole dose map. To correct for these dose errors, a compensation method involving centric k-space ordering is suggested. Computer simulations have been performed to analyse the robustness of the proposed method. Applying the compensated sequence, a temperature rise of 3 C leads to a narrow dose artefact of the order of 3% for a 'worst case' situation in which a single pixel dose gradient is assumed. Negligible deviations are found in the rest of the dose map.

Mesh:

Substances:

Year:  2001        PMID: 11686283     DOI: 10.1088/0031-9155/46/10/312

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Optical-CT gel-dosimetry I: basic investigations.

Authors:  Mark Oldham; Jeffrey H Siewerdsen; Sai Kumar; John Wong; David A Jaffray
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter.

Authors:  M Mahdavi; M KhademAbolfazli; S-R-M Mahdavi; Gh Ataei
Journal:  J Biomed Phys Eng       Date:  2013-06-01

4.  Adaptation of radiation field analyser (RFA) as optical CT scanner for gel dosimetry.

Authors:  S Brindha; Vinoth Kumar; S Vasanth; B Ravindran Paul
Journal:  J Med Phys       Date:  2006-01

5.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01

Review 6.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.