Literature DB >> 25473653

A Prototype Body-Mounted MRI-Compatible Robot for Needle Guidance in Shoulder Arthrography.

R Monfaredi1, R Seifabadi2, I Iordachita3, R Sze2, N M Safdar2, K Sharma2, S Fricke4, A Krieger2, K Cleary2.   

Abstract

A novel compact and lightweight patient-mounted MRI-compatible robot has been designed for MRI image-guided interventions. This robot is intended to enable MRI-guided needle placement as done in shoulder arthrography. The robot could make needle placement more accurate and simplify the current workflow by converting the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure (streamlined workflow all in MRI suite). The robot has 4 degrees of freedom (DOF), two for orientation of the needle and two for needle positioning. The mechanical design was based on several criteria including rigidity, MRI compatibility, compact design, sterilizability, and adjustability. The proposed workflow is discussed and initial MRI compatibility experiments are presented. The results show that artifacts in the region of interest are minimal and that MRI images of the shoulder were not adversely affected by placing the robot on a human volunteer.

Entities:  

Year:  2014        PMID: 25473653      PMCID: PMC4248365          DOI: 10.1109/BIOROB.2014.6913749

Source DB:  PubMed          Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron        ISSN: 2155-1774


  5 in total

1.  Interventional radiology robot for CT and MRI guided percutaneous interventions.

Authors:  Nikolai Hungr; Céline Fouard; Adeline Robert; Ivan Bricault; Philippe Cinquin
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

2.  A patient-mounted robotic platform for CT-scan guided procedures.

Authors:  Benjamin Maurin; Bernard Bayle; Olivier Piccin; Jacques Gangloff; Michel de Mathelin; Christophe Doignon; Philippe Zanne; Afshin Gangi
Journal:  IEEE Trans Biomed Eng       Date:  2008-10       Impact factor: 4.538

3.  Light puncture robot for CT and MRI interventions: designing a new robotic architecture to perform abdominal and thoracic punctures.

Authors:  Ivan Bricault; Nabil Zemiti; Emilie Jouniaux; Céline Fouard; Elise Taillant; Frederic Dorandeu; Philippe Cinquin
Journal:  IEEE Eng Med Biol Mag       Date:  2008 May-Jun

4.  Trends in pediatric sports-related and recreation-related Injuries in the United States in the last decade.

Authors:  Marios G Lykissas; Emily A Eismann; Shital N Parikh
Journal:  J Pediatr Orthop       Date:  2013-12       Impact factor: 2.324

5.  Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions.

Authors:  Reza Seifabadi; Iulian Iordachita; Gabor Fichtinger
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2012-12-31
  5 in total
  8 in total

1.  Preclinical evaluation of an integrated robotic system for magnetic resonance imaging guided shoulder arthrography.

Authors:  Niravkumar Patel; Jiawen Yan; Reza Monfaredi; Karun Sharma; Kevin Cleary; Iulian Iordachita
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-15

Review 2.  Enabling Technology for MRI-Guided Intervention.

Authors:  Farzad Sedaghat; Kemal Tuncali
Journal:  Top Magn Reson Imaging       Date:  2018-02

3.  An Integrated Robotic System for MRI-Guided Neuroablation: Preclinical Evaluation.

Authors:  Niravkumar A Patel; Christopher J Nycz; Paulo A Carvalho; Katie Y Gandomi; Radian Gondokaryono; Gang Li; Tamas Heffter; Everette Clif Burdette; Julie G Pilitsis; Gregory S Fischer
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-17       Impact factor: 4.538

4.  Development of a shoulder-mounted robot for MRI-guided needle placement: phantom study.

Authors:  Reza Monfaredi; Iulian Iordachita; Emmanuel Wilson; Raymond Sze; Karun Sharma; Axel Krieger; Stanley Fricke; Kevin Cleary
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-08-11       Impact factor: 2.924

5.  MRI Robots for Needle-Based Interventions: Systems and Technology.

Authors:  Reza Monfaredi; Kevin Cleary; Karun Sharma
Journal:  Ann Biomed Eng       Date:  2018-06-19       Impact factor: 3.934

6.  State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.

Authors:  Hao Su; Ka-Wai Kwok; Kevin Cleary; Iulian Iordachita; M Cenk Cavusoglu; Jaydev P Desai; Gregory S Fischer
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-05-03       Impact factor: 14.910

7.  An MR-Conditional Needle Driver for Robot-Assisted Spinal Injections: Design Modifications and Evaluations.

Authors:  Yanzhou Wang; Guanyun Liu; Gang Li; Kevin Cleary; Iulian Iordachita
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2022-07

8.  Body-Mounted Robotic System for MRI-Guided Shoulder Arthrography: Cadaver and Clinical Workflow Studies.

Authors:  Niravkumar Patel; Jiawen Yan; Gang Li; Reza Monfaredi; Lukasz Priba; Helen Donald-Simpson; Joyce Joy; Andrew Dennison; Andreas Melzer; Karun Sharma; Iulian Iordachita; Kevin Cleary
Journal:  Front Robot AI       Date:  2021-05-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.