Literature DB >> 25471952

Impact of spot size on plan quality of spot scanning proton radiosurgery for peripheral brain lesions.

Dongxu Wang1, Blake Dirksen1, Daniel E Hyer1, John M Buatti1, Arshin Sheybani1, Eric Dinges1, Nicole Felderman1, Mindi TenNapel1, John E Bayouth1, Ryan T Flynn1.   

Abstract

PURPOSE: To determine the plan quality of proton spot scanning (SS) radiosurgery as a function of spot size (in-air sigma) in comparison to x-ray radiosurgery for treating peripheral brain lesions.
METHODS: Single-field optimized (SFO) proton SS plans with sigma ranging from 1 to 8 mm, cone-based x-ray radiosurgery (Cone), and x-ray volumetric modulated arc therapy (VMAT) plans were generated for 11 patients. Plans were evaluated using secondary cancer risk and brain necrosis normal tissue complication probability (NTCP).
RESULTS: For all patients, secondary cancer is a negligible risk compared to brain necrosis NTCP. Secondary cancer risk was lower in proton SS plans than in photon plans regardless of spot size (p = 0.001). Brain necrosis NTCP increased monotonically from an average of 2.34/100 (range 0.42/100-4.49/100) to 6.05/100 (range 1.38/100-11.6/100) as sigma increased from 1 to 8 mm, compared to the average of 6.01/100 (range 0.82/100-11.5/100) for Cone and 5.22/100 (range 1.37/100-8.00/100) for VMAT. An in-air sigma less than 4.3 mm was required for proton SS plans to reduce NTCP over photon techniques for the cohort of patients studied with statistical significance (p = 0.0186). Proton SS plans with in-air sigma larger than 7.1 mm had significantly greater brain necrosis NTCP than photon techniques (p = 0.0322).
CONCLUSIONS: For treating peripheral brain lesions--where proton therapy would be expected to have the greatest depth-dose advantage over photon therapy--the lateral penumbra strongly impacts the SS plan quality relative to photon techniques: proton beamlet sigma at patient surface must be small (<7.1 mm for three-beam single-field optimized SS plans) in order to achieve comparable or smaller brain necrosis NTCP relative to photon radiosurgery techniques. Achieving such small in-air sigma values at low energy (<70 MeV) is a major technological challenge in commercially available proton therapy systems.

Entities:  

Mesh:

Year:  2014        PMID: 25471952     DOI: 10.1118/1.4901260

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment.

Authors:  Blake Smith; Edgar Gelover; Alexandra Moignier; Dongxu Wang; Ryan T Flynn; Liyong Lin; Maura Kirk; Tim Solberg; Daniel E Hyer
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

2.  Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation.

Authors:  Alexandra Moignier; Edgar Gelover; Blake R Smith; Dongxu Wang; Ryan T Flynn; Maura L Kirk; Liyong Lin; Timothy D Solberg; Alexander Lin; Daniel E Hyer
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

3.  Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents.

Authors:  Blake R Smith; Daniel E Hyer; Ryan T Flynn; Patrick M Hill; Wesley S Culberson
Journal:  Phys Med Biol       Date:  2019-10-21       Impact factor: 3.609

Review 4.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

5.  Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy.

Authors:  Maryam Moteabbed; Torunn I Yock; Nicolas Depauw; Thomas M Madden; Hanne M Kooy; Harald Paganetti
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-12-29       Impact factor: 7.038

6.  The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy.

Authors:  Blake R Smith; Nicholas P Nelson; Theodore J Geoghegan; Kaustubh A Patwardhan; Patrick M Hill; Jen Yu; Alonso N Gutiérrez; Bryan G Allen; Daniel E Hyer
Journal:  Med Phys       Date:  2022-02-21       Impact factor: 4.071

7.  Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy.

Authors:  Nicholas P Nelson; Wesley S Culberson; Daniel E Hyer; Blake R Smith; Ryan T Flynn; Patrick M Hill
Journal:  Biomed Phys Eng Express       Date:  2022-02-18

8.  Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.

Authors:  Theodore J Geoghegan; Nicholas P Nelson; Ryan T Flynn; Patrick M Hill; Suresh Rana; Daniel E Hyer
Journal:  Med Phys       Date:  2020-04-06       Impact factor: 4.071

9.  Improving Head and Neck Cancer Treatments Using Dynamic Collimation in Spot Scanning Proton Therapy.

Authors:  Alexandra Moignier; Edgar Gelover; Dongxu Wang; Blake Smith; Ryan Flynn; Maura Kirk; Liyong Lin; Timothy Solberg; Alexander Lin; Daniel Hyer
Journal:  Int J Part Ther       Date:  2016-03-24

10.  Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy.

Authors:  Daniel E Hyer; Laura C Bennett; Theodore J Geoghegan; Martin Bues; Blake R Smith
Journal:  Int J Part Ther       Date:  2021-06-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.