Diagnostic confidence and image quality of CT pulmonary angiography at 100 kVp in overweight and obese patients.

B Megyeri1, A Christe2, S T Schindera3, E Horkay4, J Sikula4, J L Cullmann2, J Kollar4, J T Heverhagen2, Z Szucs-Farkas5.   

Abstract

AIM: To compare image quality and diagnostic confidence of 100 kVp CT pulmonary angiography (CTPA) in patients with body weights (BWs) below and above 100kg.
MATERIALS AND METHODS: The present retrospective study comprised 216 patients (BWs of 75-99kg, 114 patients; 100-125kg, 88 patients; >125kg, 14 patients), who received 100 kVp CTPA to exclude pulmonary embolism. The attenuation was measured and the contrast-to-noise ratio (CNR) was calculated in the pulmonary trunk. Size-specific dose estimates (SSDEs) were evaluated. Three blinded radiologists rated subjective image quality and diagnostic confidence. Results between the BW groups and between three body mass index (BMI) groups (BMI <25kg/m(2), BMI = 25-29.9kg/m(2), and BMI ≥30kg/m(2), i.e., normal weight, overweight, and obese patients) were compared using the Kruskal-Wallis test.
RESULTS: Vessel attenuation was higher and SDDE was lower in the 75-99kg group than at higher BWs (p-values between <0.001 and 0.03), with no difference between the 100-125 and >125kg groups (p = 0.892 and 1). Subjective image quality and diagnostic confidence were not different among the BW groups (p = 0.225 and 1). CNR was lower (p < 0.006) in obese patients than in normal weight or overweight subjects. Diagnostic confidence was not different in the BMI groups (p = 0.105).
CONCLUSION: CTPA at 100 kVp tube voltage can be used in patients weighing up to 125kg with no significant deterioration of subjective image quality and confidence. The applicability of 100 kVp in the 125-150kg BW range needs further testing in larger collectives.
Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25459197     DOI: 10.1016/j.crad.2014.09.014

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  4 in total

1.  Coronary CT angiography in obese patients using 3(rd) generation dual-source CT: effect of body mass index on image quality.

Authors:  Stefanie Mangold; Julian L Wichmann; U Joseph Schoepf; Sheldon E Litwin; Christian Canstein; Akos Varga-Szemes; Giuseppe Muscogiuri; Stephen R Fuller; Andrew C Stubenrauch; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2015-12-28       Impact factor: 5.315

2.  Automated Deep Learning Analysis for Quality Improvement of CT Pulmonary Angiography.

Authors:  Lewis D Hahn; Kent Hall; Thamer Alebdi; Seth J Kligerman; Albert Hsiao
Journal:  Radiol Artif Intell       Date:  2022-02-23

Review 3.  Imaging of suspected pulmonary embolism and deep venous thrombosis in obese patients.

Authors:  Vincent Cascio; Man Hon; Linda B Haramati; Animesh Gour; Peter Spiegler; Sanjeev Bhalla; Douglas S Katz
Journal:  Br J Radiol       Date:  2018-06-27       Impact factor: 3.039

4.  CT pulmonary angiography: simultaneous low-pitch dual-source acquisition mode with 70 kVp and 40 ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection.

Authors:  Johannes Boos; Patric Kröpil; Rotem S Lanzman; Joel Aissa; Christoph Schleich; Philipp Heusch; Lino M Sawicki; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.