Literature DB >> 25450784

Second-generation sequencing of forensic STRs using the Ion Torrent™ HID STR 10-plex and the Ion PGM™.

Sarah L Fordyce1, Helle Smidt Mogensen2, Claus Børsting3, Robert E Lagacé4, Chien-Wei Chang5, Narasimhan Rajagopalan6, Niels Morling7.   

Abstract

Second-generation sequencing (SGS) using Roche/454 and Illumina platforms has proved capable of sequencing the majority of the key forensic genetic STR systems. Given that Roche has announced that the 454 platforms will no longer be supported from 2015, focus should now be shifted to competing SGS platforms, such as the MiSeq (Illumina) and the Ion Personal Genome Machine (Ion PGM™; Thermo Fisher). There are currently several challenges faced with amplicon-based SGS STR typing in forensic genetics, including current lengths of amplicons for CE-typing and lack of uniform data analysis between laboratories. Thermo Fisher has designed a human identification (HID) short tandem repeat (STR) 10-plex panel including amelogenin, CSF1PO, D16S539, D3S1358, D5S818, D7S820, D8S1179, TH01, TPOX and vWA, where the primers have been designed specifically for the purpose of SGS and the data analysis is supported by Ion Torrent™ software. Hence, the combination of the STR 10-plex and the Ion PGM™ represents the first fully integrated SGS STR typing solution from PCR to data analysis. In this study, four experiments were performed to evaluate the alpha-version of the STR 10-plex: (1) typing of control samples; (2) analysis of sensitivity; (3) typing of mixtures; and (4) typing of biological crime case samples. Full profiles and concordant results between replicate SGS runs and CE-typing were observed for all control samples. Full profiles were seen with DNA input down to 50 pg, with the exception of a single locus drop-out in one of the 100 pg dilutions. Mixtures were easily deconvoluted down to 20:1, although alleles from the minor contributor had to be identified manually as some signals were not called by the Ion Torrent™ software. Interestingly, full profiles were obtained for all biological samples from real crime and identification cases, in which only partial profiles were obtained with PCR-CE assays. In conclusion, the Ion Torrent™ HID STR 10-plex panel offers an all-in-one solution from amplification of STRs and amelogenin, and sequencing to data analysis.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Ion PGM™; Massively parallel DNA sequencing; Second-generation sequencing (SGS); Short tandem repeat (STR)

Mesh:

Year:  2014        PMID: 25450784     DOI: 10.1016/j.fsigen.2014.09.020

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  20 in total

1.  Comparison between magnetic bead and qPCR library normalisation methods for forensic MPS genotyping.

Authors:  Bhavik Mehta; Samantha Venables; Paul Roffey
Journal:  Int J Legal Med       Date:  2017-04-18       Impact factor: 2.686

Review 2.  Increasing the reach of forensic genetics with massively parallel sequencing.

Authors:  Bruce Budowle; Sarah E Schmedes; Frank R Wendt
Journal:  Forensic Sci Med Pathol       Date:  2017-06-19       Impact factor: 2.007

3.  Effects of the Ion PGM™ Hi-Q™ sequencing chemistry on sequence data quality.

Authors:  Jennifer D Churchill; Jonathan L King; Ranajit Chakraborty; Bruce Budowle
Journal:  Int J Legal Med       Date:  2016-03-30       Impact factor: 2.686

4.  A novel forensic panel of 186-plex SNPs and 123-plex STR loci based on massively parallel sequencing.

Authors:  Xinyao Miao; Yuesheng Shen; Xiaojuan Gong; Huiyun Yu; Bowen Li; Liao Chang; Yinan Wang; Jingna Fan; Zuhuan Liang; Bowen Tan; Shengbin Li; Bao Zhang
Journal:  Int J Legal Med       Date:  2020-08-26       Impact factor: 2.686

5.  Time-Dependent Hormetic Response of Soil Alkaline Phosphatase Induced by Cd and the Association with Bacterial Community Composition.

Authors:  Jiangang Han; Shengyan Wang; Diwu Fan; Yanhui Guo; Chenglei Liu; Yongli Zhu
Journal:  Microb Ecol       Date:  2019-04-05       Impact factor: 4.552

6.  Blind study evaluation illustrates utility of the Ion PGM™ system for use in human identity DNA typing.

Authors:  Jennifer D Churchill; Joseph Chang; Jianye Ge; Narasimhan Rajagopalan; Sharon C Wootton; Chien-Wei Chang; Robert Lagacé; Wenchi Liao; Jonathan L King; Bruce Budowle
Journal:  Croat Med J       Date:  2015-06       Impact factor: 1.351

7.  A comparison of rumen microbial profiles in dairy cows as retrieved by 454 Roche and Ion Torrent (PGM) sequencing platforms.

Authors:  Nagaraju Indugu; Kyle Bittinger; Sanjay Kumar; Bonnie Vecchiarelli; Dipti Pitta
Journal:  PeerJ       Date:  2016-02-04       Impact factor: 2.984

8.  A massively parallel strategy for STR marker development, capture, and genotyping.

Authors:  Logan Kistler; Stephen M Johnson; Mitchell T Irwin; Edward E Louis; Aakrosh Ratan; George H Perry
Journal:  Nucleic Acids Res       Date:  2017-09-06       Impact factor: 16.971

9.  A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis.

Authors:  Brian Young; Jonathan L King; Bruce Budowle; Luigi Armogida
Journal:  PLoS One       Date:  2017-05-18       Impact factor: 3.240

10.  Digital fragment analysis of short tandem repeats by high-throughput amplicon sequencing.

Authors:  Brian J Darby; Shay F Erickson; Samuel D Hervey; Susan N Ellis-Felege
Journal:  Ecol Evol       Date:  2016-06-08       Impact factor: 2.912

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.