Literature DB >> 25449502

Impact of stent strut design in metallic stents and biodegradable scaffolds.

Nicolas Foin1, Renick D Lee2, Ryo Torii3, Juan Luis Guitierrez-Chico4, Alessio Mattesini5, Sukhjinder Nijjer6, Sayan Sen6, Ricardo Petraco6, Justin E Davies6, Carlo Di Mario5, Michael Joner7, Renu Virmani7, Philip Wong2.   

Abstract

Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Bioabsorbable scaffolds; DES; Neointimal coverage; PCI; Re-endothelialization; Strut thickness

Mesh:

Substances:

Year:  2014        PMID: 25449502     DOI: 10.1016/j.ijcard.2014.09.143

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  24 in total

Review 1.  New generation bioresorbable scaffold technologies: an update on novel devices and clinical results.

Authors:  Damiano Regazzoli; Pier Pasquale Leone; Antonio Colombo; Azeem Latib
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

Review 2.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

3.  Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: an analysis from the randomized BIOFLOW trials.

Authors:  Rayyan Hemetsberger; Mohammad Abdelghani; Ralph Toelg; Hector M Garcia-Garcia; Serdar Farhan; Nader Mankerious; Karim Elbasha; Abdelhakim Allali; Stephan Windecker; Thierry Lefèvre; Shigeru Saito; David Kandzari; Ron Waksman; Gert Richardt
Journal:  Clin Res Cardiol       Date:  2022-02-25       Impact factor: 5.460

4.  Stent strut streamlining and thickness reduction promote endothelialization.

Authors:  Duy T Nguyen; Alexander F Smith; Juan M Jiménez
Journal:  J R Soc Interface       Date:  2021-08-18       Impact factor: 4.293

Review 5.  Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents.

Authors:  Hui Ying Ang; Ying Ying Huang; Soo Teik Lim; Philip Wong; Michael Joner; Nicolas Foin
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

6.  Designing Better Cardiovascular Stent Materials - A Learning Curve.

Authors:  Irsalan Cockerill; Carmine Wang See; Marcus L Young; Yadong Wang; Donghui Zhu
Journal:  Adv Funct Mater       Date:  2020-11-04       Impact factor: 18.808

7.  Long-Term Outcomes After Implantation of Magnesium-Based Bioresorbable Scaffolds-Insights From an All-Comer Registry.

Authors:  Matthias Bossard; Mehdi Madanchi; Dardan Avdijaj; Adrian Attinger-Toller; Giacomo Maria Cioffi; Thomas Seiler; Gregorio Tersalvi; Richard Kobza; Guido Schüpfer; Florim Cuculi
Journal:  Front Cardiovasc Med       Date:  2022-04-14

8.  Stent platforms anno 2015: is there still a place for bare metal stents at the front line?

Authors:  Jors Nicolaas van der Sijde; Evelyn Regar
Journal:  Neth Heart J       Date:  2015-02       Impact factor: 2.380

Review 9.  Cardiovascular Stents: A Review of Past, Current, and Emerging Devices.

Authors:  Alexandru Scafa Udriște; Adelina-Gabriela Niculescu; Alexandru Mihai Grumezescu; Elisabeta Bădilă
Journal:  Materials (Basel)       Date:  2021-05-12       Impact factor: 3.623

10.  Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals.

Authors:  Yun-Feng Yan; Long Jiang; Ming-Duo Zhang; Xin-He Li; Mao-Xiao Nie; Ting-Ting Feng; Xin Zhao; Lu-Ya Wang; Quan-Ming Zhao
Journal:  PLoS One       Date:  2016-03-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.