Literature DB >> 34404229

Stent strut streamlining and thickness reduction promote endothelialization.

Duy T Nguyen1, Alexander F Smith2, Juan M Jiménez1,2.   

Abstract

Stent thrombosis (ST) carries a high risk of myocardial infarction and death. Lack of endothelial coverage is an important prognostic indicator of ST after stenting. While stent strut thickness is a critical factor in ST, a mechanistic understanding of its effect is limited and the role of haemodynamics is unclear. Endothelialization was tested using a wound-healing assay and five different stent strut models ranging in height between 50 and 150 µm for circular arc (CA) and rectangular (RT) geometries and a control without struts. Under static conditions, all stent strut surfaces were completely endothelialized. Reversing pulsatile disturbed flow caused full endothelialization, except for the stent strut surfaces of the 100 and 150 µm RT geometries, while fully antegrade pulsatile undisturbed flow with a higher mean wall shear stress caused only the control and the 50 µm CA geometries to be fully endothelialized. Modest streamlining and decrease in height of the stent struts improved endothelial coverage of the peri-strut and stent strut surfaces in a haemodynamics dependent manner. This study highlights the impact of the stent strut height (thickness) and geometry (shape) on the local haemodynamics, modulating reendothelialization after stenting, an important factor in reducing the risk of stent thrombosis.

Entities:  

Keywords:  endothelialization; shear stress; stent; stent streamlining; wound healing

Mesh:

Year:  2021        PMID: 34404229      PMCID: PMC8371379          DOI: 10.1098/rsif.2021.0023

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.293


  72 in total

Review 1.  Rho GTPases in cell biology.

Authors:  Sandrine Etienne-Manneville; Alan Hall
Journal:  Nature       Date:  2002-12-12       Impact factor: 49.962

2.  Time course of stent endothelialization after intravascular radiation therapy in rabbit iliac arteries.

Authors:  Edouard Cheneau; Michael C John; Jana Fournadjiev; Rosanna C Chan; Han-Soo Kim; Laurent Leborgne; Rajbabu Pakala; Hamid Yazdi; Andrew E Ajani; Renu Virmani; Ron Waksman
Journal:  Circulation       Date:  2003-04-14       Impact factor: 29.690

3.  Images in cardiovascular medicine. Vascular healing 4 years after the implantation of sirolimus-eluting stent in humans: a histopathological examination.

Authors:  J Eduardo Sousa; Marco A Costa; Andrew Farb; Alexandre Abizaid; Amanda Sousa; Ana C Seixas; Lilian M da Silva; Fausto Feres; Ibraim Pinto; Luiz A Mattos; Renu Virmani
Journal:  Circulation       Date:  2004-07-06       Impact factor: 29.690

4.  Bifunctional polymer brush-grafted coronary stent for anticoagulation and endothelialization.

Authors:  Tianyu Zhu; Wentao Gao; Dan Fang; Zhiyong Liu; Guangyan Wu; Min Zhou; Mimi Wan; Chun Mao
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2020-11-14       Impact factor: 7.328

5.  Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries.

Authors:  John F LaDisa; Lars E Olson; Robert C Molthen; Douglas A Hettrick; Phillip F Pratt; Michael D Hardel; Judy R Kersten; David C Warltier; Paul S Pagel
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-01-14       Impact factor: 4.733

6.  Microvascular endothelial cells migrate upstream and align against the shear stress field created by impinging flow.

Authors:  Maggie A Ostrowski; Ngan F Huang; Travis W Walker; Tom Verwijlen; Charlotte Poplawski; Amanda S Khoo; John P Cooke; Gerald G Fuller; Alexander R Dunn
Journal:  Biophys J       Date:  2014-01-21       Impact factor: 4.033

7.  Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings.

Authors:  Kumaran Kolandaivelu; Rajesh Swaminathan; William J Gibson; Vijaya B Kolachalama; Kim-Lien Nguyen-Ehrenreich; Virginia L Giddings; Leslie Coleman; Gee K Wong; Elazer R Edelman
Journal:  Circulation       Date:  2011-03-21       Impact factor: 29.690

8.  Stent endothelialization. Time course, impact of local catheter delivery, feasibility of recombinant protein administration, and response to cytokine expedition.

Authors:  E Van Belle; F O Tio; T Couffinhal; L Maillard; J Passeri; J M Isner
Journal:  Circulation       Date:  1997-01-21       Impact factor: 29.690

9.  Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments.

Authors:  Juan Mejia; Bilal Ruzzeh; Rosaire Mongrain; Richard Leask; Olivier F Bertrand
Journal:  Biomed Eng Online       Date:  2009-04-30       Impact factor: 2.819

Review 10.  Overview of the coagulation system.

Authors:  Sanjeev Palta; Richa Saroa; Anshu Palta
Journal:  Indian J Anaesth       Date:  2014-09