Abstract

Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were tested in two ways, first to a sub-failure load at a constant displacement rate, then to fracture in an impact fall simulator. Comparisons of sub-failure energy and stiffness were made between the tests at the same compressive force. Additionally, the impact failure tests were compared with previous, constant displacement rate failure tests (at 2 and 100mm/s) in terms of energy, yield force, and stiffness. Loading and displacement rates were characterized and related to specimen stiffness in the impact tests. No differences were observed between the sub-failure constant displacement and impact tests in the aforementioned metrics. Comparisons between failure tests showed that the impact group had the lowest absorbed energy, 24% lower maximum force and 160% higher stiffness than the 100mm/s group (p<0.01 for all), but suffered from low statistical power to differentiate the donor age and specimen BMD. Loading and displacement rates for the specimens tested using impact varied during each test and between specimens and did not show appreciable viscoelasticity. These results indicate that constant displacement rate testing may help understand sub-failure mechanical behaviour, but may not elucidate failure behaviours. The differences between the impact and constant displacement rate fall simulations have important ramifications for interpreting the results of previous experiments. Crown
Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone; Falls; Hip fracture; Impact

Mesh:

Year:  2014        PMID: 25443780     DOI: 10.1016/j.jbiomech.2014.06.040

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

Review 1.  Sideways fall-induced impact force and its effect on hip fracture risk: a review.

Authors:  M Nasiri Sarvi; Y Luo
Journal:  Osteoporos Int       Date:  2017-07-20       Impact factor: 4.507

2.  Optimizing Accuracy of Proximal Femur Elastic Modulus Equations.

Authors:  Asghar Rezaei; Kent D Carlson; Hugo Giambini; Samad Javid; Dan Dragomir-Daescu
Journal:  Ann Biomed Eng       Date:  2019-03-12       Impact factor: 3.934

3.  Factors associated with proximal femur fracture determined in a large cadaveric cohort.

Authors:  Dan Dragomir-Daescu; Timothy L Rossman; Asghar Rezaei; Kent D Carlson; David F Kallmes; John A Skinner; Sundeep Khosla; Shreyasee Amin
Journal:  Bone       Date:  2018-08-08       Impact factor: 4.398

4.  Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

Authors:  Asghar Rezaei; Hugo Giambini; Timothy Rossman; Kent D Carlson; Michael J Yaszemski; Lichun Lu; Dan Dragomir-Daescu
Journal:  Ann Biomed Eng       Date:  2017-09-22       Impact factor: 3.934

5.  The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment.

Authors:  Pratik Nag; Bhaskar Borgohain; Kashif Akhtar Ahmed; Pranjal Phukan; Neeraj Kumar; Alireza Borjali; Kartik Mangudi Varadarajan; Souptick Chanda
Journal:  Ann Biomed Eng       Date:  2022-07-12       Impact factor: 4.219

6.  Perspectives on the non-invasive evaluation of femoral strength in the assessment of hip fracture risk.

Authors:  M L Bouxsein; P Zysset; C C Glüer; M McClung; E Biver; D D Pierroz; S L Ferrari
Journal:  Osteoporos Int       Date:  2020-01-03       Impact factor: 4.507

7.  Large cortical bone pores in the tibia are associated with proximal femur strength.

Authors:  Gianluca Iori; Johannes Schneider; Andreas Reisinger; Frans Heyer; Laura Peralta; Caroline Wyers; Melanie Gräsel; Reinhard Barkmann; Claus C Glüer; J P van den Bergh; Dieter Pahr; Kay Raum
Journal:  PLoS One       Date:  2019-04-17       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.