Literature DB >> 25423958

Effect of a real-time radiation monitoring device on operator radiation exposure during cardiac catheterization: the radiation reduction during cardiac catheterization using real-time monitoring study.

Georgios Christopoulos1, Aristotelis C Papayannis1, Mohammed Alomar1, Anna Kotsia1, Tesfaldet T Michael1, Bavana V Rangan1, Michele Roesle1, Deborah Shorrock1, Lorenza Makke1, Ronald Layne1, Rebecca Grabarkewitz1, Donald Haagen1, Spyros Maragkoudakis1, Atif Mohammad1, Karan Sarode1, Daisha J Cipher1, Charles E Chambers1, Subhash Banerjee1, Emmanouil S Brilakis2.   

Abstract

BACKGROUND: The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring study sought to examine the effect of a radiation detection device that provides real-time operator dose reporting through auditory feedback (Bleeper Sv; Vertec Scientific Ltd; Berkshire, UK) on patient dose and operator exposure during cardiac catheterization. METHODS AND
RESULTS: Between January 2012 and May 2014, 505 patients undergoing coronary angiography, percutaneous coronary intervention, or both were randomized to use (n=253) or no use (n=252) of the Bleeper Sv radiation monitor. Operator radiation exposure was measured in both groups using a second, silent radiation exposure monitoring device. Mean patient age was 65±8 years, most patients (99%) were men, and 30% had prior coronary artery bypass graft surgery. Baseline clinical characteristics were similar in the 2 study groups. Radial access was used in 18% and chronic total occlusion percutaneous coronary intervention constituted 7% of the total procedures. Median procedure time was 17 (12-27) minutes for diagnostic angiography, 42 (28-70) minutes for percutaneous coronary intervention, and 27 (14-51) minutes in the overall study population, with similar distribution between the study groups. First (9 [4-17] versus 14 [7-25] μSv; P<0.001) and second (5 [2-10] versus 7 [4-14] μSv; P<0.001) operator radiation exposure was significantly lower in the Bleeper Sv group. Use of the device did not result in a significant reduction in patient radiation dose. The effect of the Bleeper Sv device on operator radiation exposure was consistent among various study subgroups.
CONCLUSIONS: Use of a real-time radiation monitoring device that provides auditory feedback can significantly reduce operator radiation exposure during cardiac catheterization. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01510353.
© 2014 American Heart Association, Inc.

Entities:  

Keywords:  cardiac catheterization; quality improvement; radiation

Mesh:

Year:  2014        PMID: 25423958     DOI: 10.1161/CIRCINTERVENTIONS.114.001974

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  10 in total

1.  Predictors of Excess Patient Radiation Exposure During Chronic Total Occlusion Coronary Intervention: Insights From a Contemporary Multicentre Registry.

Authors:  Georgios E Christakopoulos; Georgios Christopoulos; Dimitri Karmpaliotis; Khaldoon Alaswad; Robert W Yeh; Farouc A Jaffer; Michael R Wyman; William L Lombardi; Muhammad Nauman J Tarar; J Aaron Grantham; David E Kandzari; Nicholas Lembo; Jeffrey W Moses; Ajay J Kirtane; Manish Parikh; Philip Green; Matthew Finn; Santiago Garcia; Anthony H Doing; Raja Hatem; Craig A Thompson; Subhash Banerjee; Emmanouil S Brilakis
Journal:  Can J Cardiol       Date:  2016-11-11       Impact factor: 5.223

2.  Selective anti-scatter grid removal during coronary angiography and PCI: a simple and safe technique for radiation reduction.

Authors:  James R Roy; Philip Sun; Glenn Ison; Ananth M Prasan; Tom Ford; Andrew Hopkins; David R Ramsay; James C Weaver
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-24       Impact factor: 2.357

3.  Radiation exposure protection: small things matter.

Authors:  D G Buys; S C Brown
Journal:  Cardiovasc J Afr       Date:  2021 Sep-Oct       Impact factor: 1.167

4.  DOES RADIOLOGICAL PROTECTION TRAINING OR A REAL-TIME STAFF DOSEMETER DISPLAY REDUCE STAFF DOSES DURING X-RAY-GUIDED PULMONARY BRONCHOSCOPY?

Authors:  Lise-Lott Lundvall; Michael Sandborg
Journal:  Radiat Prot Dosimetry       Date:  2022-04-26       Impact factor: 0.954

5.  Radiation protection in cardiovascular interventions: what can we do?

Authors:  Qiang Liu; Qinghua Wu
Journal:  Med Princ Pract       Date:  2015-03-21       Impact factor: 1.927

6.  Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

Authors:  Anna M Sailer; Laura Vergoossen; Leonie Paulis; Willem H van Zwam; Marco Das; Joachim E Wildberger; Cécile R L P N Jeukens
Journal:  Cardiovasc Intervent Radiol       Date:  2017-05-12       Impact factor: 2.740

7.  Cardiology fellows-in-training are exposed to relatively high levels of radiation in the cath lab compared with staff interventional cardiologists-insights from the RECAP trial.

Authors:  W Vlastra; B E Claessen; M A Beijk; K D Sjauw; G J Streekstra; J J Wykrzykowska; M M Vis; K T Koch; R J de Winter; J J Piek; J P S Henriques; R Delewi
Journal:  Neth Heart J       Date:  2019-06       Impact factor: 2.380

8.  Occupational radiation exposure in femoral artery approach is higher than radial artery approach during coronary angiography or percutaneous coronary intervention.

Authors:  Jung-Su Kim; Bong-Ki Lee; Dong-Ryeol Ryu; Kwangjin Chun; Ho-Seok Kwon; So-Ra Nam; Doo-Il Kim; Sung-Yun Lee; Jin-Ok Jeong; Jang-Whan Bae; Jong-Seon Park; Youngkeun Ahn; Je-Keon Chae; Myeong-Ho Yoon; Seung-Hwan Lee; Jeonghan Yoon; Hyeon-Cheol Gwon; Donghoon Choi; Soon-Mu Kwon; Young-Hoon Roh; Byung-Ryul Cho
Journal:  Sci Rep       Date:  2020-04-28       Impact factor: 4.379

Review 9.  Radiation protection for the interventional cardiologist: Practical approach and innovations.

Authors:  Alejandro Gutierrez-Barrios; Dolores Cañadas-Pruaño; Inmaculada Noval-Morillas; Livia Gheorghe; Ricardo Zayas-Rueda; German Calle-Perez
Journal:  World J Cardiol       Date:  2022-01-26

10.  Effect of Different Anthropometric Body Indexes on Radiation Exposure in Patients Undergoing Cardiac Catheterisation and Percutaneous Coronary Intervention.

Authors:  Youlin Koh; Sara Vogrin; Samer Noaman; Simon Lam; Raymond Pham; Andrew Clark; Leah Biffin; Laura B Hanson; Jason E Bloom; Dion Stub; Angela L Brennan; Christopher Reid; Diem T Dinh; Jeffrey Lefkovits; Nicholas Cox; William Chan
Journal:  Tomography       Date:  2022-09-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.