Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction.

Sung Sil Son1, Ki Seok Choo, Ung Bae Jeon, Gye Rok Jeon, Kyung Jin Nam, Tae Un Kim, Jeong A Yeom, Jae Yeon Hwang, Dong Wook Jeong, Soo Jin Lim.   

Abstract

To retrospectively evaluate the image quality of CT angiography (CTA) reconstructed by model-based iterative reconstruction (MBIR) and to compare this with images obtained by filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) in newborns and infants with congenital heart disease (CHD). Thirty-seven children (age 4.8 ± 3.7 months; weight 4.79 ± 0.47 kg) with suspected CHD underwent CTA on a 64detector MDCT without ECG gating (80 kVp, 40 mA using tube current modulation). Total dose length product was recorded in all patients. Images were reconstructed using FBP, ASIR, and MBIR. Objective image qualities (density, noise) were measured in the great vessels and heart chambers. The contrast-to-noise ratio (CNR) was calculated by measuring the density and noise of myocardial walls. Two radiologists evaluated images for subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery. Images were compared with respect to reconstruction method, and reconstruction times were measured. Images from all patients were diagnostic, and the effective dose was 0.22 mSv. The objective image noise of MBIR was significantly lower than those of FBP and ASIR in the great vessels and heart chambers (P < 0.05); however, with respect to attenuations in the four chambers, ascending aorta, descending aorta, and pulmonary trunk, no statistically significant difference was observed among the three methods (P > 0.05). Mean CNR values were 8.73 for FBP, 14.54 for ASIR, and 22.95 for MBIR. In addition, the subjective image noise of MBIR was significantly lower than those of the others (P < 0.01). Furthermore, while FBP had the highest score for image sharpness, ASIR had the highest score for diagnostic confidence (P < 0.05), and mean reconstruction times were 5.1 ± 2.3 s for FBP and ASIR and 15.1 ± 2.4 min for MBIR. While CTA with MBIR in newborns and infants with CHD can reduce image noise and improve CNR more than other methods, it is more time-consuming than the other methods.

Entities:  

Mesh:

Year:  2014        PMID: 25414055     DOI: 10.1007/s10554-014-0570-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

1.  Unenhanced helical CT using increased pitch for suspected renal colic: an effective technique for radiation dose reduction?

Authors:  J Diel; S Perlmutter; N Venkataramanan; R Mueller; M J Lane; D S Katz
Journal:  J Comput Assist Tomogr       Date:  2000 Sep-Oct       Impact factor: 1.826

Review 2.  MDCT of postoperative anatomy and complications in adults with cyanotic heart disease.

Authors:  Marilyn J Siegel; Sanjeev Bhalla; Fernando R Gutierrez; Joseph B Billadello
Journal:  AJR Am J Roentgenol       Date:  2005-01       Impact factor: 3.959

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography.

Authors:  Mannudeep K Kalra; Mischa Woisetschläger; Nils Dahlström; Sarabjeet Singh; Maria Lindblom; Garry Choy; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Michael A Blake; Anders Persson
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

6.  Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

Authors:  Daniel Cornfeld; Gary Israel; Ezra Detroy; Jamal Bokhari; Hamid Mojibian
Journal:  AJR Am J Roentgenol       Date:  2011-03       Impact factor: 3.959

7.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

8.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach.

Authors:  Frédéric A Miéville; François Gudinchet; Francis Brunelle; François O Bochud; Francis R Verdun
Journal:  Phys Med       Date:  2012-01-02       Impact factor: 2.685

9.  Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease.

Authors:  B Kelly Han; Jana Lindberg; Katharine Grant; Robert S Schwartz; John R Lesser
Journal:  Am J Cardiol       Date:  2011-05-15       Impact factor: 2.778

Review 10.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

View more
  3 in total

1.  Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography.

Authors:  Lin Yang; Jian Zhuang; Meiping Huang; Changhong Liang; Hui Liu
Journal:  Pediatr Radiol       Date:  2016-09-16

Review 2.  3D Approaches in Complex CHD: Where Are We? Funny Printing and Beautiful Images, or a Useful Tool?

Authors:  Adriani Spanaki; Saleha Kabir; Natasha Stephenson; Milou P M van Poppel; Valentina Benetti; John Simpson
Journal:  J Cardiovasc Dev Dis       Date:  2022-08-15

3.  Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison.

Authors:  Ernesto Forte; Serena Monti; Chiara Anna Parente; Lukas Beyer; Roberto De Rosa; Teresa Infante; Carlo Cavaliere; Filippo Cademartiri; Marco Salvatore; Christian Stroszczynski; Carlo Tedeschi
Journal:  Dose Response       Date:  2018-10-16       Impact factor: 2.658

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.