Literature DB >> 25391758

Association of left ventricular diastolic dysfunction with 24-h aortic ambulatory blood pressure: the SAFAR study.

Y Zhang1, G Kollias2, A A Argyris2, T G Papaioannou3, C Tountas2, G D Konstantonis2, A Achimastos4, J Blacher5, M E Safar5, P P Sfikakis2, A D Protogerou2.   

Abstract

Aortic blood pressure (BP) and 24-h ambulatory BP are both better associated with target organ damage than office brachial BP. However, it remains unclear whether a combination of these two techniques would be the optimal methodology to evaluate patients' BP in terms of left ventricular diastolic dysfunction (LVDD) prevention. In 230 participants, office brachial and aortic BPs were measured by a validated BP monitor and a tonometry-based device, respectively. 24-h ambulatory brachial and aortic BPs were measured by a validated ambulatory BP monitor (Mobil-O-Graph, Germany). Systematic assessment of patients' LVDD was performed. After adjustment for age, gender, hypertension and antihypertensive treatment, septum and lateral E/Ea were significantly associated with office aortic systolic BP (SBP) and pulse pressure (PP) and 24-h brachial and aortic SBP and PP (P ⩽ 0.04), but not with office brachial BP (P ⩾ 0.09). Similarly, 1 standard deviation in SBP was significantly associated with 97.8 ± 20.9, 86.4 ± 22.9, 74.1 ± 23.3 and 51.3 ± 22.6 in septum E/Ea and 68.6 ± 2 0.1, 54.2 ± 21.9, 37.9 ± 22.4 and 23.1 ± 21.4 in lateral E/Ea, for office and 24-h aortic and brachial SBP, respectively. In qualitative analysis, except for office brachial BP, office aortic and 24-h brachial and aortic BPs were all significantly associated with LVDD (P ⩽ 0.03), with the highest odds ratio in 24-h aortic SBP. Furthermore, aortic BP, no matter in the office or 24-h ambulatory setting, showed the largest area under receiver operating characteristic curves (P ⩽ 0.02). In conclusion, 24-h aortic BP is superior to other BPs in the association with LVDD.

Entities:  

Mesh:

Year:  2014        PMID: 25391758     DOI: 10.1038/jhh.2014.101

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  31 in total

1.  A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor.

Authors:  C R Jones; K Taylor; P Chowienczyk; L Poston; A H Shennan
Journal:  Blood Press Monit       Date:  2000-08       Impact factor: 1.444

2.  Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria.

Authors:  Pascal M L Franssen; Ben P M Imholz
Journal:  Blood Press Monit       Date:  2010-08       Impact factor: 1.444

3.  Central blood pressure estimation for the masses moves a step closer.

Authors:  I B Wilkinson; C M McEniery; J R Cockcroft
Journal:  J Hum Hypertens       Date:  2010-05-06       Impact factor: 3.012

4.  Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device.

Authors:  Wolfgang Weiss; Christopher Gohlisch; Christl Harsch-Gladisch; Markus Tölle; Walter Zidek; Markus van der Giet
Journal:  Blood Press Monit       Date:  2012-06       Impact factor: 1.444

Review 5.  Role of pulse pressure amplification in arterial hypertension: experts' opinion and review of the data.

Authors:  Alberto P Avolio; Luc M Van Bortel; Pierre Boutouyrie; John R Cockcroft; Carmel M McEniery; Athanase D Protogerou; Mary J Roman; Michel E Safar; Patrick Segers; Harold Smulyan
Journal:  Hypertension       Date:  2009-06-29       Impact factor: 10.190

6.  Progression of left ventricular diastolic dysfunction and risk of heart failure.

Authors:  Garvan C Kane; Barry L Karon; Douglas W Mahoney; Margaret M Redfield; Veronique L Roger; John C Burnett; Steven J Jacobsen; Richard J Rodeheffer
Journal:  JAMA       Date:  2011-08-24       Impact factor: 56.272

7.  Cardiac hypertrophy in hypertension: relation to 24-h blood pressure profile and arterial stiffness.

Authors:  John P Lekakis; Nicos A Zakopoulos; Athanassios D Protogerou; Vassilios Th Kotsis; Theodore G Papaioannou; Kimon S Stamatelopoulos; Marios D Tsitsiricos; Vassiliki Ch Pitiriga; Christos M Papamichael; Savvas Th Toumanides; Myron E Mavrikakis
Journal:  Int J Cardiol       Date:  2004-10       Impact factor: 4.164

8.  Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol.

Authors:  George S Stergiou; Dimitris Tzamouranis; Athanasios Protogerou; Efthimia Nasothimiou; Christos Kapralos
Journal:  Blood Press Monit       Date:  2008-10       Impact factor: 1.444

9.  Mechanism(s) of selective systolic blood pressure reduction after a low-dose combination of perindopril/indapamide in hypertensive subjects: comparison with atenolol.

Authors:  Gérard M London; Roland G Asmar; Michaël F O'Rourke; Michel E Safar
Journal:  J Am Coll Cardiol       Date:  2004-01-07       Impact factor: 24.094

10.  How to diagnose diastolic heart failure: a consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology.

Authors:  Walter J Paulus; Carsten Tschöpe; John E Sanderson; Cesare Rusconi; Frank A Flachskampf; Frank E Rademakers; Paolo Marino; Otto A Smiseth; Gilles De Keulenaer; Adelino F Leite-Moreira; Attila Borbély; István Edes; Martin Louis Handoko; Stephane Heymans; Natalia Pezzali; Burkert Pieske; Kenneth Dickstein; Alan G Fraser; Dirk L Brutsaert
Journal:  Eur Heart J       Date:  2007-04-11       Impact factor: 29.983

View more
  21 in total

Review 1.  How to Measure 24-hour Central Blood Pressure and Its Potential Clinical Implications.

Authors:  Giacomo Pucci; Francesca Battista; Alessandra Crocetti; Giovanni Tilocca; Enrico Boschetti
Journal:  High Blood Press Cardiovasc Prev       Date:  2017-04-10

2.  Association of left ventricular structural and functional abnormalities with aortic and brachial blood pressure variability in hypertensive patients: the SAFAR study.

Authors:  C Chi; S-K Yu; R Auckle; A A Argyris; E Nasothimiou; C Tountas; E Aissopou; J Blacher; M E Safar; P P Sfikakis; Y Zhang; A D Protogerou
Journal:  J Hum Hypertens       Date:  2017-06-01       Impact factor: 3.012

Review 3.  Twenty-Four-Hour Ambulatory Pulse Wave Analysis in Hypertension Management: Current Evidence and Perspectives.

Authors:  Stefano Omboni; Igor N Posokhov; Yulia V Kotovskaya; Athanase D Protogerou; Jacques Blacher
Journal:  Curr Hypertens Rep       Date:  2016-10       Impact factor: 5.369

4.  Relationship of Office and Ambulatory Blood Pressure With Left Ventricular Global Longitudinal Strain.

Authors:  Fusako Sera; Zhezhen Jin; Cesare Russo; Edward S Lee; Joseph E Schwartz; Tatjana Rundek; Mitchell S V Elkind; Shunichi Homma; Ralph L Sacco; Marco R Di Tullio
Journal:  Am J Hypertens       Date:  2016-11-01       Impact factor: 2.689

Review 5.  Ambulatory arterial stiffness in chronic kidney disease: a methodological review.

Authors:  Andrea László; György Reusz; János Nemcsik
Journal:  Hypertens Res       Date:  2015-12-03       Impact factor: 3.872

6.  Central Blood Pressure Waves Assessment: A Validation Study of Non-invasive Aortic Pressure Measurement in Human Beings.

Authors:  Ramiro Sánchez; Franco Pessana; Gabriel Lev; Micaela Mirada; Oscar Mendiz; Agustín Ramírez; Edmundo Cabrera Fischer
Journal:  High Blood Press Cardiovasc Prev       Date:  2020-03-25

7.  24-hour aortic blood pressure variability showed a stronger association with carotid damage than 24-hour brachial blood pressure variability: The SAFAR study.

Authors:  Shikai Yu; Chen Chi; Athanase D Protogerou; Michel E Safar; Jacques Blacher; Antonis A Argyris; Efthimia G Nasothimiou; Petros P Sfikakis; Theodore G Papaioannou; Henry Xu; Yi Zhang; Yawei Xu
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-02-19       Impact factor: 3.738

8.  Hypertensive target organ damage is better associated with central than brachial blood pressure: The Northern Shanghai Study.

Authors:  Chen Chi; Xuejing Yu; Ranshaka Auckle; Yuyan Lu; Ximin Fan; Shikai Yu; Jing Xiong; Bin Bai; Jiadela Teliewubai; Yiwu Zhou; Hongwei Ji; Jue Li; Yi Zhang; Yawei Xu
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-10-25       Impact factor: 3.738

9.  Pulsatile and steady-state 24-hour hemodynamics in adolescents and young adults: The next steps ahead.

Authors:  Thomas Weber; Athanasios D Protogerou; James E Sharman; Siegfried Wassertheurer
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-08-11       Impact factor: 3.738

10.  Insight into the 24-hour ambulatory central blood pressure in adolescents and young adults.

Authors:  Angeliki Ntineri; Anastasios Kollias; Maria Elena Zeniodi; Andriani Vazeou; Alexandra Soldatou; George S Stergiou
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-08-19       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.