Literature DB >> 20658764

Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria.

Pascal M L Franssen1, Ben P M Imholz.   

Abstract

We report on the validation of the new generation Mobil-O-Graph 24/48 h ambulatory blood pressure monitor according to the criteria of the European Society of Hypertension. In 15 individuals participating in phase I for systolic pressure, all 45 measures differed less than 15 mmHg, 43 and 33 out of 45 differed less than 10 and 5 mmHg. As for diastolic pressures even better scores were reached when the device passed the EHS score. In phase II, data were collected in an additional 18 individuals leaving a total of 33 individuals and 99 measures. The phase counts the achieved percentages of two or three measures per individual within 15, 10 and 5 mmHg limits. Systolic pressures exceeded the required 95, 80 and 65% for 15, 10 and 5 mmHg differences with values of 98, 94 and 71%, respectively. As again for diastolic pressure the values were even better, the device passed phase II also. Thus, all phases of the European Society of Hypertension procedure were passed and the results of this study can recommend the use of the Mobil-O-Graph new generation ambulatory blood pressure monitor device in clinical practice.

Entities:  

Mesh:

Year:  2010        PMID: 20658764     DOI: 10.1097/mbp.0b013e328339be38

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  67 in total

1.  Association of left ventricular diastolic dysfunction with 24-h aortic ambulatory blood pressure: the SAFAR study.

Authors:  Y Zhang; G Kollias; A A Argyris; T G Papaioannou; C Tountas; G D Konstantonis; A Achimastos; J Blacher; M E Safar; P P Sfikakis; A D Protogerou
Journal:  J Hum Hypertens       Date:  2014-11-13       Impact factor: 3.012

2.  Effects of nondipping pattern on systemic inflammation in obstructive sleep apnea.

Authors:  Sevinc Sarinc Ulasli; Muzaffer Sarıaydın; Ersin Gunay; Bilal Halici; Sefa Celik; Tulay Koyuncu; Sena Ulu; Mehmet Unlu
Journal:  Sleep Breath       Date:  2015-02-28       Impact factor: 2.816

3.  Effect of supraphysiological estrogen levels on arterial stiffness and hemodynamic parameters.

Authors:  Murat Akçay; Ayşe Zehra Özdemir
Journal:  Anatol J Cardiol       Date:  2021-05       Impact factor: 1.596

4.  Ambulatory recording of wave reflections and arterial stiffness during intra- and interdialytic periods in patients treated with dialysis.

Authors:  Antonios Karpetas; Pantelis A Sarafidis; Panagiotis I Georgianos; Athanase Protogerou; Pantelis Vakianis; Georgios Koutroumpas; Vasileios Raptis; Dimitrios N Stamatiadis; Christos Syrganis; Vassilios Liakopoulos; Georgios Efstratiadis; Anastasios N Lasaridis
Journal:  Clin J Am Soc Nephrol       Date:  2015-01-29       Impact factor: 8.237

5.  Excess volume removal following lung ultrasound evaluation decreases central blood pressure and pulse wave velocity in hemodialysis patients: a LUST sub-study.

Authors:  Charalampos Loutradis; Aikaterini Papagianni; Robert Ekart; Marieta Theodorakopoulou; Ioanna Minopoulou; Efstathios Pagourelias; Stella Douma; Asterios Karagiannis; Francesca Mallamaci; Carmine Zoccali; Gerard London; Pantelis A Sarafidis
Journal:  J Nephrol       Date:  2020-05-23       Impact factor: 3.902

6.  Changes in Aortic Pulse Wave Velocity and the Predictors of Improvement in Arterial Stiffness Following Aortic Valve Replacement.

Authors:  Emir Cantürk; Beytullah Çakal; Oğuz Karaca; Onur Omaygenç; Salih Salihi; Arda Özyüksel; Atıf Akçevin
Journal:  Ann Thorac Cardiovasc Surg       Date:  2017-09-08       Impact factor: 1.520

7.  Frequency of early vascular aging and associated risk factors among an adult population in Latin America: the OPTIMO study.

Authors:  Fernando Botto; Sebastian Obregon; Fernando Rubinstein; Angelo Scuteri; Peter M Nilsson; Carol Kotliar
Journal:  J Hum Hypertens       Date:  2018-02-20       Impact factor: 3.012

8.  Changes in Central 24-h Ambulatory Blood Pressure and Hemodynamics 12 Months After Bariatric Surgery: the BARIHTA Study.

Authors:  Anna Oliveras; Albert Goday; Laia Sans; Carlos E Arias; Susana Vazquez; David Benaiges; José Manuel Ramon; Julio Pascual
Journal:  Obes Surg       Date:  2020-01       Impact factor: 4.129

Review 9.  Twenty-Four-Hour Ambulatory Pulse Wave Analysis in Hypertension Management: Current Evidence and Perspectives.

Authors:  Stefano Omboni; Igor N Posokhov; Yulia V Kotovskaya; Athanase D Protogerou; Jacques Blacher
Journal:  Curr Hypertens Rep       Date:  2016-10       Impact factor: 5.369

10.  A comparison study of brachial blood pressure recorded with Spacelabs 90217A and Mobil-O-Graph NG devices under static and ambulatory conditions.

Authors:  P A Sarafidis; A A Lazaridis; K P Imprialos; P I Georgianos; K A Avranas; A D Protogerou; M N Doumas; V G Athyros; A I Karagiannis
Journal:  J Hum Hypertens       Date:  2016-03-03       Impact factor: 3.012

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.