Nazish Fatima1. 1. Dr-Ishrat-Ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Science, Karachi, Pakistan.
Abstract
PURPOSE: The aim of present study was to evaluate extended curing times on the degree of conversion (DC) of filled and unfilled resin-based materials used as pit and fissure sealants. MATERIALS AND METHODS: The materials examined were a flowable composite (Filtek™ Z350 XT Flowable) and a pit and fissure sealant (Clinpro™ Sealant). Thirty disks of each material were prepared. The 30 made of the flowable composite were divided into three groups (n = 10 each) according to the three different curing times studied: 20 s (group 1), 40 s (group 2), and 60 s (group 3). Similarly, the 30 disks made of the pit and fissure sealant were divided into three groups (n = 10 each) according to the three different curing times: 20 s (group 4), 40 s (group 5), and 60 s (group 6). After polymerization, the disks were removed from the mold and stored in dry, lightproof containers in an incubator at 37 °C for 24 h. The DC was obtained using an Avatar 320 FTIR spectrometer. Then the data were analyzed using the Kruskal-Wallis test and the Fisher's least significant difference post hoc test for multiple comparisons (alpha = 0.05). RESULTS: DC values for the flowable composite (Filtek™ Z350 XT) were higher (p = 0.002) than those for the pit and fissure sealant (Clinpro™ Sealant). Group 2 and group 5 showed significantly higher DC values than group 1 and group 4, respectively. There was no difference between groups 2 and 3 or between groups 5 and 6 (p = 2.93). CONCLUSION: An extended curing time improves the DC to some extent for both materials.
PURPOSE: The aim of present study was to evaluate extended curing times on the degree of conversion (DC) of filled and unfilled resin-based materials used as pit and fissure sealants. MATERIALS AND METHODS: The materials examined were a flowable composite (Filtek™ Z350 XT Flowable) and a pit and fissure sealant (Clinpro™ Sealant). Thirty disks of each material were prepared. The 30 made of the flowable composite were divided into three groups (n = 10 each) according to the three different curing times studied: 20 s (group 1), 40 s (group 2), and 60 s (group 3). Similarly, the 30 disks made of the pit and fissure sealant were divided into three groups (n = 10 each) according to the three different curing times: 20 s (group 4), 40 s (group 5), and 60 s (group 6). After polymerization, the disks were removed from the mold and stored in dry, lightproof containers in an incubator at 37 °C for 24 h. The DC was obtained using an Avatar 320 FTIR spectrometer. Then the data were analyzed using the Kruskal-Wallis test and the Fisher's least significant difference post hoc test for multiple comparisons (alpha = 0.05). RESULTS: DC values for the flowable composite (Filtek™ Z350 XT) were higher (p = 0.002) than those for the pit and fissure sealant (Clinpro™ Sealant). Group 2 and group 5 showed significantly higher DC values than group 1 and group 4, respectively. There was no difference between groups 2 and 3 or between groups 5 and 6 (p = 2.93). CONCLUSION: An extended curing time improves the DC to some extent for both materials.
Entities:
Keywords:
Curing time; Degree of conversion; Pit and fissure sealants; Spectrometer
Authors: Jean Beauchamp; Page W Caufield; James J Crall; Kevin J Donly; Robert Feigal; Barbara Gooch; Amid Ismail; William Kohn; Mark Siegal; Richard Simonsen Journal: Dent Clin North Am Date: 2009-01
Authors: Luana Gonçalves; Jaime D N Filho; José G A Guimarães; Laiza T Poskus; Eduardo M Silva Journal: J Biomed Mater Res B Appl Biomater Date: 2008-05 Impact factor: 3.368