Literature DB >> 25381873

Using the ubiquitous pH meter combined with a loop mediated isothermal amplification method for facile and sensitive detection of Nosema bombycis genomic DNA PTP1.

Shunbi Xie1, Yali Yuan, Yue Song, Ying Zhuo, Tian Li, Yaqin Chai, Ruo Yuan.   

Abstract

Here we show an amplification-coupled detection method for directly measuring released hydrogen ions during the loop mediated isothermal amplification (LAMP) procedure by using a pH meter. The genomic DNA of Nosema bombycis (N. bombycis) was amplified and detected by employing this LAMP-pH meter platform for the first time.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25381873     DOI: 10.1039/c4cc06449f

Source DB:  PubMed          Journal:  Chem Commun (Camb)        ISSN: 1359-7345            Impact factor:   6.222


  5 in total

1.  [A colorimetric method for vascular endothelial growth factor detection based on aptamer and magnetic beads].

Authors:  Jing-Rong Liu; Yun-Ling Pan; Yan-Ping Zhao; Mei-Cen Liu; Jing-Hua Chen; Chun-Yan Li
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2016-02-20

2.  Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection.

Authors:  Mohammadali Safavieh; Manoj K Kanakasabapathy; Farhang Tarlan; Minhaz U Ahmed; Mohammed Zourob; Waseem Asghar; Hadi Shafiee
Journal:  ACS Biomater Sci Eng       Date:  2016-01-21

Review 3.  Nucleic Acids Analysis.

Authors:  Yongxi Zhao; Xiaolei Zuo; Qian Li; Feng Chen; Yan-Ru Chen; Jinqi Deng; Da Han; Changlong Hao; Fujian Huang; Yanyi Huang; Guoliang Ke; Hua Kuang; Fan Li; Jiang Li; Min Li; Na Li; Zhenyu Lin; Dingbin Liu; Juewen Liu; Libing Liu; Xiaoguo Liu; Chunhua Lu; Fang Luo; Xiuhai Mao; Jiashu Sun; Bo Tang; Fei Wang; Jianbin Wang; Lihua Wang; Shu Wang; Lingling Wu; Zai-Sheng Wu; Fan Xia; Chuanlai Xu; Yang Yang; Bi-Feng Yuan; Quan Yuan; Chao Zhang; Zhi Zhu; Chaoyong Yang; Xiao-Bing Zhang; Huanghao Yang; Weihong Tan; Chunhai Fan
Journal:  Sci China Chem       Date:  2020-12-02       Impact factor: 9.445

4.  Translating in vitro diagnostics from centralized laboratories to point-of-care locations using commercially-available handheld meters.

Authors:  JingJing Zhang; Tian Lan; Yi Lu
Journal:  Trends Analyt Chem       Date:  2019-12-23       Impact factor: 12.296

5.  A Sensitive Potentiometric Sensor for Isothermal Amplification-Coupled Detection of Nucleic Acids.

Authors:  Kang-Ho Lee; Dongkyu Lee; Jongsu Yoon; Ohwon Kwon; Jaejong Lee
Journal:  Sensors (Basel)       Date:  2018-07-14       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.