Literature DB >> 25323838

Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions.

De Chao Jiao1, Teng Fei Li, Xin Wei Han, Gang Wu, Ji Ma, Ming Ti Fu, Qi Sun, Janina Beilner.   

Abstract

PURPOSE: This study explored the value of flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy (PTNB) for lung lesions in clinical practice.
METHODS: A total of 110 patients with solid lung lesions were enrolled to undergo PTNB procedures. The mean diameter of lesions was 4.63 cm (range, 0.6-15cm). The needle path was carefully planned and calculated on the C-arm CT system, which acquired three-dimensional CT-like cross-sectional images. The PTNB procedures were performed under needle guidance with fluoroscopic feedbacks.
RESULTS: Histopathologic tissue was successfully obtained from 108 patients with a puncture success rate of 98.2% (108/110). The diagnostic accuracy rate was found to be 96.3% (104/108). There was only one case of pneumothorax (0.9%) requiring therapy. The rates of mild pneumothorax and hemoptysis were low (12.0% and 6.5%, respectively). In addition, procedural time could be limited with this technique, which helped to reduce X-ray exposure.
CONCLUSION: Our study shows that C-arm CT-based needle guidance enables reliable and efficient needle positioning and progression by providing real-time intraoperative guidance.

Entities:  

Mesh:

Year:  2014        PMID: 25323838      PMCID: PMC4463285          DOI: 10.5152/dir.2014.13463

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  25 in total

1.  Real-Time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility.

Authors:  S J Braak; M J L van Strijen; M van Leersum; H W van Es; J P M van Heesewijk
Journal:  AJR Am J Roentgenol       Date:  2010-05       Impact factor: 3.959

2.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

3.  C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules.

Authors:  Hye Sun Hwang; Myung Jin Chung; Ju Won Lee; Sung Wook Shin; Kyung Soo Lee
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

5.  Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Authors:  M J Choi; Y Kim; Y S Hong; S S Shim; S M Lim; J K Lee
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

6.  CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.

Authors:  Ga Ram Kim; Jin Hur; Sang Min Lee; Hye-Jeong Lee; Yoo Jin Hong; Ji Eun Nam; Hua Sun Kim; Young Jin Kim; Byoung Wook Choi; Tae Hoon Kim; Kyu Ok Choe
Journal:  Eur Radiol       Date:  2010-08-22       Impact factor: 5.315

7.  C-arm cone beam CT for hepatic tumor ablation under real-time 3D imaging.

Authors:  Manabu Morimoto; Kazushi Numata; Masaaki Kondo; Akito Nozaki; Shingo Hamaguchi; Shigeo Takebayashi; Katsuaki Tanaka
Journal:  AJR Am J Roentgenol       Date:  2010-05       Impact factor: 3.959

8.  Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield.

Authors:  A M Priola; S M Priola; A Cataldi; L Errico; M Di Franco; P Campisi; L Molinaro; V Marci; S Novello; C Fava
Journal:  Radiol Med       Date:  2007-12-13       Impact factor: 3.469

9.  CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure.

Authors:  Takao Hiraki; Hidefumi Mimura; Hideo Gobara; Toshihiro Iguchi; Hiroyasu Fujiwara; Jun Sakurai; Yusuke Matsui; Daisaku Inoue; Shinichi Toyooka; Yoshifumi Sano; Susumu Kanazawa
Journal:  Chest       Date:  2009-05-08       Impact factor: 9.410

10.  Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy.

Authors:  Joo Yeon Cheung; Yookyung Kim; Sung Shine Shim; Soo Mee Lim
Journal:  Korean J Radiol       Date:  2011-01-03       Impact factor: 3.500

View more
  15 in total

1.  C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications.

Authors:  Hyungjin Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-04-28       Impact factor: 5.315

2.  CT-guided transthoracic biopsy: histopathologic results and complication rates.

Authors:  Aykut Recep Aktaş; Emel Gözlek; Ömer Yılmaz; Mustafa Kayan; Nisa Ünlü; Hakan Demirtaş; Bumin Değirmenci; Mustafa Kara
Journal:  Diagn Interv Radiol       Date:  2015 Jan-Feb       Impact factor: 2.630

Review 3.  The Society for Translational Medicine: indications and methods of percutaneous transthoracic needle biopsy for diagnosis of lung cancer.

Authors:  Qinghua Zhou; Jingsi Dong; Jie He; Deruo Liu; David H Tian; Shugeng Gao; Shanqing Li; Lunxu Liu; Jianxing He; Yunchao Huang; Shidong Xu; Weimin Mao; Qunyou Tan; Chun Chen; Xiaofei Li; Zhu Zhang; Gening Jiang; Lin Xu; Lanjun Zhang; Jianhua Fu; Hui Li; Qun Wang; Lijie Tan; Danqing Li; Qinghua Zhou; Xiangning Fu; Zhongmin Jiang; Haiquan Chen; Wentao Fang; Xun Zhang; Yin Li; Ti Tong; Zhentao Yu; Yongyu Liu; Xiuyi Zhi; Tiansheng Yan; Xingyi Zhang; Roberto F Casal; Eugenio Pompeo; Angelo Carretta; Marc Riquet; Ottavio Rena; Pierre-Emmanuel Falcoz; Hisashi Saji; Ali Zamir Khan; Jose Luis Danguilan; Diego Gonzalez-Rivas; Nicolas Guibert; Chengchu Zhu; Jianfei Shen
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

4.  Percutaneous nephrolithotripsy: C-arm CT with 3D virtual navigation in non-dilated renal collecting systems.

Authors:  Dechao Jiao; Zhanli Zhang; Zhanguo Sun; Yanli Wang; Xinwei Han
Journal:  Diagn Interv Radiol       Date:  2018 Jan-Feb       Impact factor: 2.630

5.  Cone beam computed tomography virtual navigation-guided transthoracic biopsy of small (≤ 1 cm) pulmonary nodules: impact of nodule visibility during real-time fluoroscopy.

Authors:  Eui Jin Hwang; Hyungjin Kim; Chang Min Park; Soon Ho Yoon; Hyun-Ju Lim; Jin Mo Goo
Journal:  Br J Radiol       Date:  2018-04-10       Impact factor: 3.039

Review 6.  Transthoracic needle biopsy of the lung.

Authors:  David M DiBardino; Lonny B Yarmus; Roy W Semaan
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

7.  Flat detector C-arm CT-guided transthoracic needle biopsy of small (≤2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients.

Authors:  Dechao Jiao; Huifeng Yuan; Quanhui Zhang; Xinwei Han
Journal:  Radiol Med       Date:  2015-12-08       Impact factor: 3.469

8.  CT-guided percutaneous transthoracic needle biopsy for paramediastinal and nonparamediastinal lung lesions: Diagnostic yield and complications in 1484 patients.

Authors:  Ye Wang; Faming Jiang; Xiaobo Tan; Panwen Tian
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

9.  The Impact of Iterative Reconstruction in Low-Dose Computed Tomography on the Evaluation of Diffuse Interstitial Lung Disease.

Authors:  Hyun-Ju Lim; Myung Jin Chung; Kyung Eun Shin; Hye Sun Hwang; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2016-10-31       Impact factor: 3.500

10.  Chinese expert consensus statement on issues related to small specimen sampling of lung cancer.

Authors: 
Journal:  Endosc Ultrasound       Date:  2017 Jul-Aug       Impact factor: 5.628

View more