| Literature DB >> 25320202 |
Harpal S Khanuja1, Samik Banerjee2, Deepak Jain3, Robert Pivec4, Michael A Mont4.
Abstract
➤ Short bone-conserving femoral stems in total hip arthroplasty were designed to preserve proximal bone stock.➤ Given the distinct fixation principles and location of loading among these bone-conserving stems, a classification system is essential to compare clinical outcomes.➤ Due to the low quality of currently available evidence, only a weak recommendation can be provided for clinical usage of certain stem designs, while some other designs cannot be recommended at this time.➤ A high prevalence of stem malalignment, incorrect sizing, subsidence, and intraoperative fractures has been reported in a subset of these short stem designs.➤ Stronger evidence, including prospective multicenter randomized trials comparing standard stems with these newer designs, is necessary before widespread use can be recommended.Entities:
Mesh:
Year: 2014 PMID: 25320202 DOI: 10.2106/JBJS.M.00780
Source DB: PubMed Journal: J Bone Joint Surg Am ISSN: 0021-9355 Impact factor: 5.284