Literature DB >> 25316058

Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.

A Euler1, T Heye, M Kekelidze, G Bongartz, Z Szucs-Farkas, C Sommer, B Schmidt, Sebastian T Schindera.   

Abstract

OBJECTIVES: To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages.
METHODS: A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol).
RESULTS: The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively.
CONCLUSIONS: The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.

Entities:  

Mesh:

Year:  2014        PMID: 25316058     DOI: 10.1007/s00330-014-3459-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

3.  Evidence-based radiology: why and how?

Authors:  Francesco Sardanelli; Myriam G Hunink; Fiona J Gilbert; Giovanni Di Leo; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2010-01       Impact factor: 5.315

4.  Integrated circuit detector technology in abdominal CT: added value in obese patients.

Authors:  Fabian Morsbach; Sebastian Bickelhaupt; Susan Rätzer; Bernhard Schmidt; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2014-02       Impact factor: 3.959

5.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

6.  Global prevalence and trends of overweight and obesity among preschool children.

Authors:  Mercedes de Onis; Monika Blössner; Elaine Borghi
Journal:  Am J Clin Nutr       Date:  2010-09-22       Impact factor: 7.045

Review 7.  Obesity and cancer--the update 2013.

Authors:  Heiner Boeing
Journal:  Best Pract Res Clin Endocrinol Metab       Date:  2013-05-15       Impact factor: 4.690

8.  Obesity triples the radiation dose of stone protocol computerized tomography.

Authors:  Agnes J Wang; Zachariah G Goldsmith; Chu Wang; Giao Nguyen; Gastón M Astroza; Andreas Neisius; Muhammad W Iqbal; Amy M Neville; Carolyn Lowry; Greta Toncheva; Terry T Yoshizumi; Glenn M Preminger; Michael N Ferrandino; Michael E Lipkin
Journal:  J Urol       Date:  2012-12-20       Impact factor: 7.450

9.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

10.  Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians.

Authors:  John D Mathews; Anna V Forsythe; Zoe Brady; Martin W Butler; Stacy K Goergen; Graham B Byrnes; Graham G Giles; Anthony B Wallace; Philip R Anderson; Tenniel A Guiver; Paul McGale; Timothy M Cain; James G Dowty; Adrian C Bickerstaffe; Sarah C Darby
Journal:  BMJ       Date:  2013-05-21
View more
  1 in total

1.  Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.

Authors:  Katharina Martini; Kai Higashigaito; Borna K Barth; Stephan Baumueller; Hatem Alkadhi; Thomas Frauenfelder
Journal:  Br J Radiol       Date:  2015-10-22       Impact factor: 3.039

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.