Literature DB >> 25304938

Squeaking in large diameter ceramic-on-ceramic bearings in total hip arthroplasty.

Stephen M Tai1, Selin Munir1, William L Walter1, Simon J Pearce1, William K Walter1, Bernard A Zicat1.   

Abstract

We analyzed the results of 206 consecutive total hip arthroplasties performed using large diameter ceramic-on-ceramic bearings. At an average follow-up of 28months, the mean Harris Hip Score improved from 54 to 92. Fifteen (7.3%) hips were noted to squeak. There was no significant difference between silent and squeaking hips with regards to age, weight, height, BMI, range of movement, femoral head diameter, leg length, and offset or center of rotation. No correlation was present between incidence of squeaking and increasing cup inclination and anteversion. 5.2% of cups orientated within Lewinnek's safe zone squeaked. No hips required revision for squeaking. While large diameter ceramic bearings may produce squeaking, our early results of surgery using large head ceramic bearings are encouraging. However, long-term follow-up is required.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cementless; ceramic-on-ceramic; cup orientation; large diameter; squeaking

Mesh:

Substances:

Year:  2014        PMID: 25304938     DOI: 10.1016/j.arth.2014.09.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  Outcome of Ceramic-on-Ceramic Total Hip Arthroplasty with 4th Generation 36 mm Head Compared to that with 3rd Generation 28 mm Head by Propensity Score Matching.

Authors:  Soong Joon Lee; Kang Sup Yoon
Journal:  Indian J Orthop       Date:  2020-09-02       Impact factor: 1.251

Review 3.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

4.  What Is the Frequency of Noise Generation in Modern Knee Arthroplasty and Is It Associated With Residual Symptoms?

Authors:  Denis Nam; Toby Barrack; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2017-01       Impact factor: 4.176

5.  Results of Total Hip Arthroplasty after Core Decompression with Tantalum Rod for Osteonecrosis of the Femoral Head.

Authors:  Gun-Woo Lee; Kyung-Soon Park; Do-Youn Kim; Young-Min Lee; Kamolhuja Eshnazarovich Eshnazarov; Taek-Rim Yoon
Journal:  Clin Orthop Surg       Date:  2016-02-13

6.  Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence?

Authors:  Didier Hannouche; Matthieu Zingg; Hermes Miozzari; Remy Nizard; Anne Lübbeke
Journal:  EFORT Open Rev       Date:  2018-01-10

7.  Bearing surfaces in primary total hip arthroplasty.

Authors:  Luigi Zagra; Enrico Gallazzi
Journal:  EFORT Open Rev       Date:  2018-05-21

8.  Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review.

Authors:  Chen-Chen Zhao; Guo-Xin Qu; Shi-Gui Yan; Xun-Zi Cai
Journal:  J Orthop Surg Res       Date:  2018-06-01       Impact factor: 2.359

9.  Squeaking Is Common and Increases Over Time Among Patients With Long-term Follow-up After Ceramic-on-ceramic THA.

Authors:  Kevin Taniguchi; Michael Quacinella; Brian Barlow
Journal:  Clin Orthop Relat Res       Date:  2021-04-01       Impact factor: 4.176

10.  Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?: A retrospective study.

Authors:  Yuan Luo; Xue-Feng Sun; Jin Chen; Wei Cui; Tao Wang
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

View more