Literature DB >> 25304253

Patient-specific instrumentation for total knee arthroplasty: a literature review.

L Camarda1, A D'Arienzo, S Morello, G Peri, B Valentino, M D'Arienzo.   

Abstract

During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient's knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instrumentation of TKR, cost-effectiveness and lower revision rates. Aim of the current manuscript was to describe the recent improvements of the surgical technique and instrumentation of TKA, reviewing the recent literature concerning the PSI technology.

Entities:  

Mesh:

Year:  2014        PMID: 25304253     DOI: 10.1007/s12306-014-0339-7

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  45 in total

1.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

2.  Computer assisted navigation in total knee arthroplasty: comparison with conventional methods.

Authors:  Kevin C Anderson; Knute C Buehler; David C Markel
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

3.  Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty.

Authors:  Fabio Catani; Nicola Biasca; Andrea Ensini; Alberto Leardini; Luca Bianchi; Vitantonio Digennaro; Sandro Giannini
Journal:  J Bone Joint Surg Am       Date:  2008-04       Impact factor: 5.284

Review 4.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

5.  Survivorship of cemented total knee arthroplasty.

Authors:  D E Font-Rodriguez; G R Scuderi; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1997-12       Impact factor: 4.176

6.  The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens.

Authors:  Y S Anouchi; L A Whiteside; A D Kaiser; M T Milliano
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

7.  Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA.

Authors:  Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

8.  Effect of femoral component rotation and patellar design on patellar forces.

Authors:  R Singerman; H D Pagan; A B Peyser; V M Goldberg
Journal:  Clin Orthop Relat Res       Date:  1997-01       Impact factor: 4.176

9.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

Authors:  Corey Scholes; Varun Sahni; Sebastien Lustig; David A Parker; Myles R J Coolican
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-17       Impact factor: 4.342

10.  Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study.

Authors:  C S Ranawat; W F Flynn; S Saddler; K K Hansraj; M J Maynard
Journal:  Clin Orthop Relat Res       Date:  1993-01       Impact factor: 4.176

View more
  4 in total

Review 1.  Patient specific instrumentation in total knee arthroplasty: a state of the art.

Authors:  Lorenzo Mattei; Pietro Pellegrino; Michel Calò; Alessandro Bistolfi; Filippo Castoldi
Journal:  Ann Transl Med       Date:  2016-04

2.  PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study.

Authors:  Tilman Calliess; Kamil Bauer; Christina Stukenborg-Colsman; Henning Windhagen; Stefan Budde; Max Ettinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

3.  Improving MiniHip femoral prosthesis positioning using a cross-laser projection system in total hip arthroplasty by an anterolateral supine approach.

Authors:  Hideki Fujii; Tetsuo Hayama; Toshiomi Abe; Motoi Takahashi; Yohei Matsushita; Ryuichi Sato; Takuya Otani; Mitsuru Saito
Journal:  Int J Med Robot       Date:  2021-01-09       Impact factor: 2.547

Review 4.  Computer-Assisted Orthopedic Surgery: Current State and Future Perspective.

Authors:  Guoyan Zheng; Lutz P Nolte
Journal:  Front Surg       Date:  2015-12-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.