Literature DB >> 25296403

Multi-modal intra-operative navigation during distal locking of intramedullary nails.

Benoit Diotte, Pascal Fallavollita, Lejing Wang, Simon Weidert, Ekkehard Euler, Peter Thaller, Nassir Navab.   

Abstract

The interlocking of intramedullary nails is a technically demanding procedure which involves a considerable amount of X-ray acquisitions; one study lists as many as 48 to successfully complete the procedure and fix screws into 4-6 mm distal holes of the nail. We propose to design an augmented radiolucent drill to assist surgeons in completing the distal locking procedure without any additional X-ray acquisitions. Using an augmented reality fluoroscope that coregisters optical and X-ray images, we exploit solely the optical images to detect the augmented radiolucent drill and estimate its tip position in real-time. Consequently, the surgeons will be able to maintain the down the beam positioning required to drill the screws into the nail holes successfully. To evaluate the accuracy of the proposed augmented drill, we perform a preclinical study involving six surgeons and ask them to perform distal locking on dry bone phantoms. Surgeons completed distal locking 98.3% of the time using only a single X-ray image with an average navigation time of 1.4 ± 0.9 min per hole.

Entities:  

Mesh:

Year:  2014        PMID: 25296403     DOI: 10.1109/TMI.2014.2361155

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

Authors:  Xiang Wang; Severine Habert; Meng Ma; Chun-Hao Huang; Pascal Fallavollita; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-01-25       Impact factor: 2.924

2.  Intra-operative augmented reality in distal locking.

Authors:  Roberto Londei; Marco Esposito; Benoit Diotte; Simon Weidert; Ekkehard Euler; Peter Thaller; Nassir Navab; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-03-27       Impact factor: 2.924

3.  Surgical process analysis identifies lack of connectivity between sequential fluoroscopic 2D alignment as a critical impediment in femoral intramedullary nailing.

Authors:  Hamid Ebrahimi; Albert Yee; Cari Whyne
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-07-21       Impact factor: 2.924

4.  C-Arm Image-Based Surgical Path Planning Method for Distal Locking of Intramedullary Nails.

Authors:  Wei-En Hsu; Ching-Hsiao Yu; Chih-Ju Chang; Hung-Kang Wu; Tsong-Han Yu; Ching-Shiow Tseng
Journal:  Appl Bionics Biomech       Date:  2018-05-23       Impact factor: 1.781

5.  Intramedullary nail holes laser indicator, a non-invasive technique for interlocking of intramedullary nails.

Authors:  Mohammadreza Maleki; Alireza Fadaei Tehrani; Ayda Aray; Mehdi Ranjbar
Journal:  Sci Rep       Date:  2021-10-27       Impact factor: 4.379

6.  Exploratory Application of Augmented Reality/Mixed Reality Devices for Acute Care Procedure Training.

Authors:  Leo Kobayashi; Xiao Chi Zhang; Scott A Collins; Naz Karim; Derek L Merck
Journal:  West J Emerg Med       Date:  2017-12-14

7.  Wearable Augmented Reality Platform for Aiding Complex 3D Trajectory Tracing.

Authors:  Sara Condino; Benish Fida; Marina Carbone; Laura Cercenelli; Giovanni Badiali; Vincenzo Ferrari; Fabrizio Cutolo
Journal:  Sensors (Basel)       Date:  2020-03-13       Impact factor: 3.576

  7 in total