Literature DB >> 25295879

Clinical NECR in 18F-FDG PET scans: optimization of injected activity and variable acquisition time. Relationship with SNR.

T Carlier1, L Ferrer, H Necib, C Bodet-Milin, C Rousseau, F Kraeber-Bodéré.   

Abstract

The injected activity and the acquisition time per bed position for 18F-FDG PET scans are usually optimized by using metrics obtained from phantom experiments. However, optimal activity and time duration can significantly vary from a phantom set-up and from patient to patient. An approach using a patient-specific noise equivalent count rate (NECR) modelling has been previously proposed for optimizing clinical scanning protocols. We propose using the clinical NECR on a large population as a function of the body mass index (BMI) for deriving the optimal injected activity and acquisition duration per bed position. The relationship between the NEC and the signal-to-noise ratio (SNR) was assessed both in a phantom and in a clinical setting. 491 consecutive patients were retrospectively evaluated and divided into 4 BMI subgroups. Two criteria were used to optimize the injected activity and the time per bed position was adjusted using the NECR value while keeping the total acquisition time constant. Finally, the relationship between NEC and SNR was investigated using an anthropomorphic phantom and a population of 507 other patients. While the first dose regimen suggested a unique injected activity (665 MBq) regardless of the BMI, the second dose regimen proposed a variable activity and a total acquisition time according to the BMI. The NEC improvement was around 35% as compared with the local current injection rule. Variable time per bed position was derived according to BMI and anatomical region. NEC and number of true events were found to be highly correlated with SNR for the phantom set-up and partially confirmed in the patient study for the BMI subgroup under 28 kg m(-2) suggesting that for the scanner, the nonlinear reconstruction algorithm used in this study and BMI < 28 kg m(-2), NEC, or the number of true events linearly correlated with SNR(2).

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25295879     DOI: 10.1088/0031-9155/59/21/6417

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Towards enhanced PET quantification in clinical oncology.

Authors:  Habib Zaidi; Nicolas Karakatsanis
Journal:  Br J Radiol       Date:  2017-11-22       Impact factor: 3.039

2.  The impact of iterative reconstruction protocol, signal-to-background ratio and background activity on measurement of PET spatial resolution.

Authors:  Sahar Rezaei; Pardis Ghafarian; Mehrdad Bakhshayesh-Karam; Carlos F Uribe; Arman Rahmim; Saeed Sarkar; Mohammad Reza Ay
Journal:  Jpn J Radiol       Date:  2020-01-01       Impact factor: 2.374

3.  Relating18F-FDG image signal-to-noise ratio to time-of-flight noise-equivalent count rate in total-body PET using the uEXPLORER scanner.

Authors:  Edwin K Leung; Yasser G Abdelhafez; Eric Berg; Zhaoheng Xie; Xuezhu Zhang; Reimund Bayerlein; Benjamin Spencer; Elizabeth Li; Negar Omidvari; Aaron Selfridge; Simon R Cherry; Jinyi Qi; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2022-06-10       Impact factor: 4.174

Review 4.  Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

Authors:  Nicolas A Karakatsanis; Eleni Fokou; Charalampos Tsoumpas
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

5.  Image quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach.

Authors:  Gabriel Reynés-Llompart; Aida Sabaté-Llobera; Elena Llinares-Tello; Josep M Martí-Climent; Cristina Gámez-Cenzano
Journal:  Sci Rep       Date:  2019-07-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.