[Lateral hinge fractures in open wedge high tibial osteotomy].

S Schröter1, A Ateschrang, C Ihle, U Stöckle, L Konstantinidis, S Döbele.   

Abstract

BACKGROUND: Open wedge high tibial osteotomy (HTO) is an increasingly more common surgical method. A typical problem of this procedure is fracture of the lateral hinge.
OBJECTIVES: The aims of this article are to present the special issue of fractures of the lateral hinge after HTO and to discuss surgical hints on how to prevent and treat this problem.
METHODS: The results of recently published clinical studies are summarized and tips from own clinical experiences are given.
RESULTS: Type II fractures of the lateral hinge are unstable and can create a major problem. Using short spacer plates results in a problem of stability for all types of fractures.
CONCLUSION: The classification into Takeuchi grades I-III has been proven to be suitable for fractures of the lateral hinge. The TomoFix plate is a safe implant to stabilize the osteotomy in type I and III fractures with which healing can be achieved with no problems. Type II fractures can be stabilized with the TomoFix plate; however, an autologous bone graft has to be taken into consideration. For fractures of the lateral hinge short spacer plates are not recommended due to stability issues.

Entities:  

Mesh:

Year:  2014        PMID: 25288100     DOI: 10.1007/s00132-014-3026-3

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  26 in total

1.  Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment: 3-year results with regard to preoperative arthroscopic and radiographic findings.

Authors:  Philipp Niemeyer; Hagen Schmal; Oliver Hauschild; Johanna von Heyden; Norbert P Südkamp; Wolfgang Köstler
Journal:  Arthroscopy       Date:  2010-12       Impact factor: 4.772

2.  Complications in high tibial (medial opening wedge) osteotomy.

Authors:  Gunter Spahn
Journal:  Arch Orthop Trauma Surg       Date:  2003-09-30       Impact factor: 3.067

3.  TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia--early results in 92 cases.

Authors:  Alex E Staubli; Carlo De Simoni; Reto Babst; Philipp Lobenhoffer
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

4.  Stability of medial opening wedge high tibial osteotomy: a failure analysis.

Authors:  E M Nelissen; E J van Langelaan; R G H H Nelissen
Journal:  Int Orthop       Date:  2009-02-03       Impact factor: 3.075

5.  Avoiding intraoperative complications in open-wedge high tibial valgus osteotomy: technical advancement.

Authors:  Matthias Jacobi; Peter Wahl; Roland P Jakob
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-26       Impact factor: 4.342

6.  High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (Position HTO plate) without bone substitute.

Authors:  Steffen Schröter; Christoph E Gonser; Lukas Konstantinidis; Peter Helwig; Dirk Albrecht
Journal:  Arthroscopy       Date:  2011-05       Impact factor: 4.772

7.  Comparative study of medial opening-wedge high tibial osteotomy using 2 different implants.

Authors:  Woon-Hwa Jung; Chung-Woo Chun; Ji-Hoon Lee; Jae-Hun Ha; Ji-Hyae Kim; Jae-Heon Jeong
Journal:  Arthroscopy       Date:  2013-04-26       Impact factor: 4.772

8.  Five- to ten-year outcome following medial opening-wedge high tibial osteotomy with rigid plate fixation in combination with an artificial bone substitute.

Authors:  T Saito; K Kumagai; Y Akamatsu; H Kobayashi; Y Kusayama
Journal:  Bone Joint J       Date:  2014-03       Impact factor: 5.082

9.  Valgus tibial osteotomy: avoiding the pitfalls.

Authors:  G M Engel; F G Lippert
Journal:  Clin Orthop Relat Res       Date:  1981-10       Impact factor: 4.176

10.  Primary stability of four different implants for opening wedge high tibial osteotomy.

Authors:  J D Agneskirchner; D Freiling; C Hurschler; P Lobenhoffer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-11-12       Impact factor: 4.342