Literature DB >> 25280450

Effects of background suppression on the sensitivity of dual-echo arterial spin labeling MRI for BOLD and CBF signal changes.

Eidrees Ghariq1, Michael A Chappell2, Sophie Schmid3, Wouter M Teeuwisse3, Matthias J P van Osch3.   

Abstract

Dual-echo arterial spin labeling (DE-ASL) enables the simultaneous acquisition of BOLD and CBF fMRI data and is often used for calibrated BOLD and cerebrovascular CO2 reactivity measurements. DE-ASL, like all ASL techniques, suffers from a low intrinsic CBF SNR, which can be improved by suppressing the background signal via the inclusion of additional inversion pulses. However, until now this approach has been considered to be undesirable for DE-ASL, because the BOLD signal is extracted from the background signal and attenuating the background signal could decrease the sensitivity of DE-ASL scans for BOLD changes. In this study, the effect of background suppression on the sensitivity of DE-ASL MRI for BOLD and CBF signal changes with a visual stimulation paradigm was studied. Results showed that with an average background suppression level of 70% the BOLD sensitivity of DE-ASL MRI decreases slightly (15%), while the CBF sensitivity of the scans increased by almost a factor-of-two (81%). These findings support the conclusion that the gains in CBF sensitivity of DE-ASL MRI due to background suppression outweigh the slight decrease in sensitivity of these scans for BOLD changes, and thus that background suppression is highly recommended for DE-ASL.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ASL; BOLD; Background suppression; CBF; Calibrated BOLD; Cerebrovascular reactivity; Dual-echo arterial spin labeling

Mesh:

Substances:

Year:  2014        PMID: 25280450     DOI: 10.1016/j.neuroimage.2014.09.051

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  15 in total

Review 1.  Characterizing Resting-State Brain Function Using Arterial Spin Labeling.

Authors:  J Jean Chen; Kay Jann; Danny J J Wang
Journal:  Brain Connect       Date:  2015-10-06

2.  Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI.

Authors:  Geoffrey Warnock; Pinar S Özbay; Felix P Kuhn; Daniel Nanz; Alfred Buck; Andreas Boss; Cristina Rossi
Journal:  J Cereb Blood Flow Metab       Date:  2017-04-19       Impact factor: 6.200

3.  Enabling free-breathing background suppressed renal pCASL using fat imaging and retrospective motion correction.

Authors:  Isabell K Bones; Anita A Harteveld; Suzanne L Franklin; Matthias J P van Osch; Jeroen Hendrikse; Chrit T W Moonen; Clemens Bos; Marijn van Stralen
Journal:  Magn Reson Med       Date:  2019-03-18       Impact factor: 4.668

4.  Dual-echo ASL contributes to decrypting the link between functional connectivity and cerebral blow flow.

Authors:  Silvia F Storti; Ilaria Boscolo Galazzo; Stefania Montemezzi; Gloria Menegaz; Francesca B Pizzini
Journal:  Hum Brain Mapp       Date:  2017-09-08       Impact factor: 5.038

5.  Calibrated bold fMRI with an optimized ASL-BOLD dual-acquisition sequence.

Authors:  María A Fernández-Seara; Zachary B Rodgers; Erin K Englund; Felix W Wehrli
Journal:  Neuroimage       Date:  2016-08-05       Impact factor: 6.556

6.  Cardiorespiratory noise correction improves the ASL signal.

Authors:  Mahlega S Hassanpour; Qingfei Luo; W Kyle Simmons; Justin S Feinstein; Martin P Paulus; Wen-Ming Luh; Jerzy Bodurka; Sahib S Khalsa
Journal:  Hum Brain Mapp       Date:  2018-02-15       Impact factor: 5.038

7.  A constrained slice-dependent background suppression scheme for simultaneous multislice pseudo-continuous arterial spin labeling.

Authors:  Xingfeng Shao; Yi Wang; Steen Moeller; Danny J J Wang
Journal:  Magn Reson Med       Date:  2017-02-15       Impact factor: 3.737

8.  Regional Reproducibility of BOLD Calibration Parameter M, OEF and Resting-State CMRO2 Measurements with QUO2 MRI.

Authors:  Isabelle Lajoie; Felipe B Tancredi; Richard D Hoge
Journal:  PLoS One       Date:  2016-09-20       Impact factor: 3.240

9.  Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity.

Authors:  Alexander D Cohen; Andrew S Nencka; R Marc Lebel; Yang Wang
Journal:  PLoS One       Date:  2017-03-02       Impact factor: 3.240

10.  Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI.

Authors:  Alexander D Cohen; Andrew S Nencka; Yang Wang
Journal:  PLoS One       Date:  2018-02-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.