Comparing Hemorrhages and Dysmenorrhea with Copper T380A and Multiload 375 Intrauterine Devices: A Randomized Clinical Trial.

Mahnaz Shahnazi1, Somayyeh Sarrafi1, Mohammad Asgari Jafarabadi2, Sahar Azari3, Fariba Esmaili4.   

Abstract

INTRODUCTION: One of the most common complications of IUD users is bleeding and dysmenorrhea. These complications vary in the different types of IUDs. The aim of this study was to compare the bleeding and dysmenorrhea in ML CU 375 IUD and Copper T 380A IUD.
METHODS: This randomized double-blind controlled clinical trial was performed on 48 women in a health care centres from January to October 2012, in Tabriz, Iran. Participants allocated into two equal groups of receiving IUD ML CU 375 or receiving IUD Copper T 380A in randomized blocking method. Data were collected by demographic questionnaire and Higham chart and Visual Analog Scale 1 month before IUD insertion and 4 months after IUD insertion. Analysis of covariance, ANOVA with repeated measures, Friedman, Ordinal regression and SPSS Ver. 13 were used to analysis the data.
RESULTS: The results showed that the mean score of bleeding in the first four months after IUD insertion in IUD ML CU 375 users was significantly lower than IUD Copper T 380A group. In the third and fourth months in both groups showed severity of dysmenorrhea in group IUD ML CU 375 was lower than IUD Copper T 380A. The results showed that the duration of dysmenorrhea in the first four months after IUD insertion in IUD ML CU 375 group was significantly lower than IUD Copper T 380A group.
CONCLUSION: Counseling and educating women by family planning service providers about both Copper T 380A and ML CU 375 IUDs before taking IUD is recommended.

Entities:  

Keywords:  Dysmenorrhea; Hemorrhage; IUD Copper T 380A; IUD ML CU 375

Year:  2014        PMID: 25276763      PMCID: PMC4171818          DOI: 10.5681/jcs.2014.021

Source DB:  PubMed          Journal:  J Caring Sci        ISSN: 2251-9920


  17 in total

Review 1.  The multiload IUD--a U.S. researcher's evaluation of a European device.

Authors:  I C Chi
Journal:  Contraception       Date:  1992-11       Impact factor: 3.375

2.  IUD-induced uterine bleeding.

Authors:  H H El-badrawi; E S Hafez
Journal:  Contracept Deliv Syst       Date:  1980-10

Review 3.  Contraceptive efficacy of intrauterine devices.

Authors:  Patrick F Thonneau; Thierry Almont; Thierry E Almont
Journal:  Am J Obstet Gynecol       Date:  2008-01-25       Impact factor: 8.661

Review 4.  Comparative safety and effectiveness of TCu380A versus MLCu375: a systematic review of randomized trials.

Authors:  Jin Wen; Ying Li; You-Ping Li; Li Wang
Journal:  J Evid Based Med       Date:  2009-11

5.  IUD Survival and Its Determinants; a Historical Cohort Study.

Authors:  T Aghamolaei; Sh Zare; Sh Zare; Ss Tavafian; S Abedini; A Poudat
Journal:  J Res Health Sci       Date:  2007-12-28

6.  The influence of copper surface area on menstrual blood loss and iron status in women fitted with an IUD.

Authors:  I Milsom; G Rybo; G Lindstedt
Journal:  Contraception       Date:  1990-03       Impact factor: 3.375

7.  Performances of copper T 380A and multiload copper 375/250 intrauterine contraceptive devices in a comparative clinical trial.

Authors:  A O Arowojolu; E O Otolorin; O A Ladipo
Journal:  Afr J Med Med Sci       Date:  1995-03

Review 8.  Implantable contraceptives for women: effectiveness, discontinuation rates, return of fertility, and outcome of pregnancies.

Authors:  Anna Glasier
Journal:  Contraception       Date:  2002-01       Impact factor: 3.375

Review 9.  Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials.

Authors:  Paul A O'Brien; Regina Kulier; Frans M Helmerhorst; Margaret Usher-Patel; Catherine d'Arcangues
Journal:  Contraception       Date:  2008-03-18       Impact factor: 3.375

10.  The effect of the levonorgestrel-releasing intrauterine system and the copper intrauterine device on subendometrial microvascularization and uterine artery blood flow.

Authors:  Mirela Foresti Jiménez; Elisangela Arbo; Daniela Vetori; Fernando Monteiro de Freitas; João Sabino Lahorgue Cunha-Filho
Journal:  Fertil Steril       Date:  2008-01-14       Impact factor: 7.329