Literature DB >> 2323218

The influence of copper surface area on menstrual blood loss and iron status in women fitted with an IUD.

I Milsom1, G Rybo, G Lindstedt.   

Abstract

The influence of copper surface area on menstrual blood loss (MBL) was evaluated in 34 healthy women (mean age 36.4 +/- 1.4 yr, range 27-46 yr), who were fitted with a Multiload intrauterine device (IUD) with either 250 mm2 (MLCu-250) or 375 mm2 (MLCu-375) copper wire. MBL prior to IUD insertion was 54.4 +/- 10.3 ml for women subsequently fitted with a MLCu-250 and 56.9 +/- 6.9 ml for women fitted with a MLCu-375. An increase (p less than 0.01) in MBL was recorded 3 months after IUD insertion for both the women fitted with a MLCu-250 (86.4 +/- 10.3 ml) and a MLCu-375 (81.1 +/- 8.3 ml). This increase in MBL remained unchanged throughout the study period of one year. At no point were there any significant differences in MBL or increase in MBL between women fitted with a MLCu-250 or MLCu-375. There were no significant differences in serum ferritin, blood hemoglobin, hematocrit or erythrocyte indices before IUD insertion in the women grouped according to type of IUD, nor were any significant changes recorded in any of these parameters after IUD insertion. Thus, our findings that the increase in copper surface area from 250 mm2 to 375 mm2 had no effect on MBL were also substantiated by the hematological findings.

Entities:  

Keywords:  Biology; Bleeding; Contraception; Contraceptive Methods--side effects; Developed Countries; Diseases; Europe; Family Planning; Hematological Effects; Hemic System; Ingredients And Chemicals; Inorganic Chemicals; Iron; Iud, Copper Releasing--side effects; Iud--side effects; Longitudinal Studies; Metals; Northern Europe; Physiology; Research Methodology; Research Report; Scandinavia; Signs And Symptoms; Studies; Sweden

Mesh:

Substances:

Year:  1990        PMID: 2323218     DOI: 10.1016/0010-7824(90)90068-7

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  2 in total

1.  Comparing Hemorrhages and Dysmenorrhea with Copper T380A and Multiload 375 Intrauterine Devices: A Randomized Clinical Trial.

Authors:  Mahnaz Shahnazi; Somayyeh Sarrafi; Mohammad Asgari Jafarabadi; Sahar Azari; Fariba Esmaili
Journal:  J Caring Sci       Date:  2014-09-01

2.  Precision intrauterine contraception may significantly increase continuation of use: a review of long-term clinical experience with frameless copper-releasing intrauterine contraception devices.

Authors:  Dirk Wildemeersch; Ansgar Pett; Sohela Jandi; Thomas Hasskamp; Patrick Rowe; Marc Vrijens
Journal:  Int J Womens Health       Date:  2013-04-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.