Literature DB >> 25265176

Acoustic characterization of contrast-to-tissue ratio and axial resolution for dual-frequency contrast-specific acoustic angiography imaging.

Brooks D Lindsey, Juan D Rojas, K Heath Martin, Sarah E Shelton, Paul A Dayton.   

Abstract

Recently, dual-frequency transducers have enabled high-spatial-resolution and high-contrast imaging of vasculature with minimal tissue artifacts by transmitting at a low frequency and receiving broadband superharmonic echoes scattered by microbubble contrast agents. In this work, we examine the imaging parameters for optimizing contrast-to-tissue ratio (CTR) for dual-frequency imaging and the relationship with spatial resolution. Confocal piston transducers are used in a water bath setup to measure the SNR, CTR, and axial resolution for ultrasound imaging of nonlinear scattering of microbubble contrast agents when transmitting at a lower frequency (1.5 to 8 MHz) and receiving at a higher frequency (7.5 to 25 MHz). Parameters varied include the frequency and peak negative pressure of transmitted waves, center frequency of the receiving transducer, microbubble concentration, and microbubble size. CTR is maximized at the lowest transmission frequencies but would be acceptable for imaging in the 1.5 to 3.5 MHz range. At these frequencies, CTR is optimized when a receiving transducer with a center frequency of 10 MHz is used, with the maximum CTR of 25.5 dB occurring when transmitting at 1.5 MHz with a peak negative pressure of 1600 kPa and receiving with a center frequency of 10 MHz. Axial resolution is influenced more heavily by the receiving center frequency, with a weak decrease in measured pulse lengths associated with increasing transmit frequency. A microbubble population containing predominately 4-μm-diameter bubbles yielded the greatest CTR, followed by 1- and then 2-μm bubbles. Varying concentration showed little effect over the tested parameters. CTR dependence on transmit frequency and peak pressure were confirmed through in vivo imaging in two rodents. These findings may lead to improved imaging of vascular remodeling in superficial or luminal cancers such as those of the breast, prostate, and colon.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25265176     DOI: 10.1109/TUFFC.2014.006466

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  25 in total

1.  Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography.

Authors:  Sarah E Shelton; Yueh Z Lee; Mike Lee; Emmanuel Cherin; F Stuart Foster; Stephen R Aylward; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-04-07       Impact factor: 2.998

2.  Quantification of Morphological Features in Non-Contrast-Enhanced Ultrasound Microvasculature Imaging.

Authors:  Siavash Ghavami; Mahdi Bayat; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Access       Date:  2020-01-21       Impact factor: 3.367

3.  Adaptive windowing in contrast-enhanced intravascular ultrasound imaging.

Authors:  Brooks D Lindsey; K Heath Martin; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasonics       Date:  2016-04-27       Impact factor: 2.890

4.  Assessment of the Superharmonic Response of Microbubble Contrast Agents for Acoustic Angiography as a Function of Microbubble Parameters.

Authors:  Isabel G Newsome; Thomas M Kierski; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2019-06-05       Impact factor: 2.998

5.  Optimization of Contrast-to-Tissue Ratio Through Pulse Windowing in Dual-Frequency "Acoustic Angiography" Imaging.

Authors:  Brooks D Lindsey; Sarah E Shelton; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-25       Impact factor: 2.998

6.  Contrast-Enhanced Quantitative Intravascular Elastography: The Impact of Microvasculature on Model-Based Elastography.

Authors:  Steven Huntzicker; Himanshu Shekhar; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2016-02-26       Impact factor: 2.998

7.  An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.

Authors:  Marzana Mantasha Mahmud; Xun Wu; Jean Lunsford Sanders; Ali Onder Biliroglu; Oluwafemi Joel Adelegan; Isabel G Newsome; Feysel Yalcin Yamaner; Paul A Dayton; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-09       Impact factor: 2.725

8.  Real-time ultrasound angiography using superharmonic dual-frequency (2.25MHz/30MHz) cylindrical array: In vitro study.

Authors:  Zhuochen Wang; K Heath Martin; Paul A Dayton; Xiaoning Jiang
Journal:  Ultrasonics       Date:  2017-09-15       Impact factor: 2.890

9.  On the relationship between microbubble fragmentation, deflation and broadband superharmonic signal production.

Authors:  Brooks D Lindsey; Juan D Rojas; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-09       Impact factor: 2.998

10.  A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation.

Authors:  Sibo Li; Jinwook Kim; Zhuochen Wang; Sandeep Kasoji; Brooks D Lindsey; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

View more