Literature DB >> 26924697

Contrast-Enhanced Quantitative Intravascular Elastography: The Impact of Microvasculature on Model-Based Elastography.

Steven Huntzicker1, Himanshu Shekhar1, Marvin M Doyley2.   

Abstract

Model-based intravascular ultrasound elastography visualizes the stress distribution within vascular tissue-information that clinicians could use to predict the propensity of atherosclerotic plaque rupture. However, there are concerns that clusters of microvessels may reduce the accuracy of the estimated stress distribution. Consequently, we have developed a contrast-enhanced intravascular ultrasound system to investigate how plaque microvasculature affects the performance of model-based elastography. In simulations, diameters of 200, 400 and 800 μm were used, where the latter diameter represented a cluster of microvessels. In phantoms, we used a microvessel with a diameter of 750 μm. Peak stress errors of 3% and 38% were incurred in the fibrous cap when stress recovery was performed with and without a priori information about microvessel geometry. The results indicate that incorporating geometric information about plaque microvasculature obtained with contrast-enhanced ultrasound imaging improves the accuracy of estimates of the stress distribution within the fibrous cap precisely.
Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Atherosclerosis; Intravascular ultrasound; Microvasculature; Model-based elastography; Stress imaging

Mesh:

Substances:

Year:  2016        PMID: 26924697      PMCID: PMC4811726          DOI: 10.1016/j.ultrasmedbio.2015.12.024

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  49 in total

1.  Evaluation of an iterative reconstruction method for quantitative elastography.

Authors:  M M Doyley; P M Meaney; J C Bamber
Journal:  Phys Med Biol       Date:  2000-06       Impact factor: 3.609

2.  Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Circumferential stress and matrix metalloproteinase 1 in human coronary atherosclerosis. Implications for plaque rupture.

Authors:  R T Lee; F J Schoen; H M Loree; M W Lark; P Libby
Journal:  Arterioscler Thromb Vasc Biol       Date:  1996-08       Impact factor: 8.311

4.  Visualizing the stress distribution within vascular tissues using intravascular ultrasound elastography: a preliminary investigation.

Authors:  Michael S Richards; Renato Perucchio; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2015-03-31       Impact factor: 2.998

5.  High frequency nonlinear B-scan imaging of microbubble contrast agents.

Authors:  David E Goertz; Emmanuel Cherin; Andrew Needles; Raffi Karshafian; Allison S Brown; Peter N Burns; F Stuart Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-01       Impact factor: 2.725

6.  Weight-matrix structured regularization provides optimal generalized least-squares estimate in diffuse optical tomography.

Authors:  Phaneendra K Yalavarthy; Brian W Pogue; Hamid Dehghani; Keith D Paulsen
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

7.  Subharmonic contrast intravascular ultrasound for vasa vasorum imaging.

Authors:  David E Goertz; Martijn E Frijlink; Dennie Tempel; Vijay Bhagwandas; Andries Gisolf; Robert Krams; Nico de Jong; Antonius F W van der Steen
Journal:  Ultrasound Med Biol       Date:  2007-08-02       Impact factor: 2.998

8.  Biomechanical interaction between cap thickness, lipid core composition and blood pressure in vulnerable coronary plaque: impact on stability or instability.

Authors:  Gérard Finet; Jacques Ohayon; Gilles Rioufol
Journal:  Coron Artery Dis       Date:  2004-02       Impact factor: 1.439

9.  Finite element analysis of mechanics of neovessels with intraplaque hemorrhage in carotid atherosclerosis.

Authors:  Jinqiu Lu; Wanying Duan; Aike Qiao
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

10.  Noninvasive vascular displacement estimation for relative elastic modulus reconstruction in transversal imaging planes.

Authors:  Hendrik H G Hansen; Michael S Richards; Marvin M Doyley; Chris L de Korte
Journal:  Sensors (Basel)       Date:  2013-03-11       Impact factor: 3.576

View more
  2 in total

1.  Combining Subharmonic and Ultraharmonic Modes for Intravascular Ultrasound Imaging: A Preliminary Evaluation.

Authors:  Himanshu Shekhar; Jeffrey S Rowan; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2017-08-26       Impact factor: 2.998

2.  Model-based vascular elastography improves the detection of flow-induced carotid artery remodeling in mice.

Authors:  Vyacheslav A Korshunov; Hexuan Wang; Rifat Ahmed; Deanne M Mickelsen; Qian Zhou; Chen Yan; Marvin M Doyley
Journal:  Sci Rep       Date:  2017-09-21       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.