| Literature DB >> 25260625 |
M Andrés Calabró, Jung-Min Lee, Pedro F Saint-Maurice, Hyelim Yoo, Gregory J Welk.
Abstract
BACKGROUND: Accelerometers can provide accurate estimates of moderate-to-vigorous physical activity (MVPA). However, one of the limitations of these instruments is the inability to capture light activity within an acceptable range of error. The purpose of the present study was to determine the validity of different activity monitors for estimating energy expenditure (EE) of light intensity, semi-structured activities.Entities:
Mesh:
Year: 2014 PMID: 25260625 PMCID: PMC4192284 DOI: 10.1186/s12966-014-0119-7
Source DB: PubMed Journal: Int J Behav Nutr Phys Act ISSN: 1479-5868 Impact factor: 6.457
Sample characteristics (Mean ± SD)
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|
|
| 21 | 26.9 ± 4.8 | 178.5 ± 8.0 | 76.0 ± 9.6 | 23.9 ± 3.0 | 1550.6 ± 163.8 |
|
| 19 | 27.9 ± 8.4 | 165.8 ± 6.5 | 59.8 ± 9.0 | 21.7 ± 2.9 | 1997.2 ± 389.8 |
|
| 40 | 27.4 ± 6.7 | 172.4 ± 9.7 | 68.3 ± 12.3 | 22.9 ± 3.1 | 1738.1 ± 456.3 |
Figure 1Bland-Altman plots for the monitors.
Figure 2Comparisons by activity intensity (METS-minutes total). Abbreviations: Oxycon Mobile, OM; SenseWear Mini Armband, Mini; SenseWear Pro3 Armband, SWA; Actiheart, AH; Actigraph® GT3X, GT3X; ActivPAL, AP.
Sensitivity (Se) and specificity (Sp) for assessed minutes of sedentary, light and moderate intensity by monitor
|
|
|
| ||||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
| |
| Mini | 1.00 (1.00, 1.00) | 0.98 (0.95, 1.00) | 0.71 (0.55, 0.88) | 0.97 (0.91, 1.00) | 0.96 (0.90, 1.00) | 0.78 (0.64, 0.92) |
| SWA | 1.00 (1.00, 1.00) | 0.95 (0.89, 1.00) | 0.64 (0.47, 0.82) | 1.00 (1.00, 1.00) | 1.00 (1.00, 1.00) | 0.78 (0.64, 0.92) |
| AH | 1.00 (1.00, 1.00) | 0.96 (0.92, 1.00) | 0.89 (0.78, 1.00) | 0.84 (0.72, 0.97) | 0.82 (0.68, 0.96) | 0.97 (0.91, 1.00) |
| GT3X | 1.00 (1.00, 1.00) | 0.64 (0.52, 0.77) | 0.14 (0.01, 0.27) | 0.38 (0.21, 0.54) | 0.29 (0.12, 0.45) | 0.88 (0.76, 0.99) |
| AP | 1.00 (1.00, 1.00) | 0.96 (0.92, 1.00) | 0.93 (0.83, 1.00) | 0.19 (0.05, 0.32) | 0.07 (0.00, 0.17) | 1.00 (1.00, 1.00) |
Abbreviations: Oxycon Mobile, OM; SenseWear Mini Armband, Mini; SenseWear Pro3 Armband, SWA; Actiheart, AH; Actigraph® GT3X, GT3X; ActivPAL, AP.
Kappa values for OM and activity monitor minutes of sedentary, light and moderate activity
|
| |||
|---|---|---|---|
|
|
|
| |
| Mini | 0.88 (0.65, 1.00) | 0.69 (0.51, 0.87) | 0.74 (0.57, 0.90) |
| SWA | 0.70 (0.39, 1.00) | 0.66 (0.48, 0.84) | 0.77 (0.61, 0.93) |
| AH | 0.78 (0.49, 1.00) | 0.73 (0.56, 0.91) | 0.80 (0.64, 0.95) |
| GT3X | 0.19 (0.02, 0.36) | −0.49 (−0.69, −0.27) | 0.17 (−0.04, 0.38) |
| AP | 0.78 (0.49, 1.00) | 0.11 (−0.05, 0.27) | 0.08 (−0.03, 0.18) |
Abbreviations: Oxycon Mobile, OM; SenseWear Mini Armband, Mini; SenseWear Pro3 Armband, SWA; Actiheart, AH; Actigraph® GT3X, GT3X; ActivPAL, AP.