Literature DB >> 25256623

Revision surgery occurs frequently after percutaneous fixation of stable femoral neck fractures in elderly patients.

Michael S Kain1, Andrew J Marcantonio, Richard Iorio.   

Abstract

BACKGROUND: Femoral neck fractures are a major public health problem. Multiple-screw fixation is the most commonly used surgical technique for the treatment of stable femoral neck fractures. QUESTIONS/PURPOSES: We determined (1) the proportion of hips that had conversion surgery to THA, and (2) the proportion of hips that underwent repeat fracture surgery after percutaneous screw fixation of stable (Garden Stages I and II) femoral neck fractures in patients older than 65 years and the causes of these reoperations.
METHODS: We performed a retrospective study of all patients older than 65 years with stable femoral neck fractures secondary to low-energy trauma treated surgically at our institution between 2005 and 2008. We identified 121 fractures in 120 patients older than 65 years as stable (Garden Stage I or II); all were treated with percutaneous, cannulated screw fixation in an inverted triangle without performing a capsulotomy or aspiration of the fracture hematoma at the time of surgery. The average age of the patients at the time of fracture was 80 years (range, 65-100 years). Radiographs, operative reports, and medical records were reviewed. Fracture union, nonunion, osteonecrosis, intraarticular hardware, loss of fixation, and conversion to arthroplasty were noted. Followup averaged 11 months (range, 0-5 years) because all patients were included, including those who died. The mortality rate was 40% for all patients at the time of review.
RESULTS: Twelve patients (10%) underwent conversion surgery to THA at a mean of 9 months after the index fracture repair (range, 2-24 months); the indications for conversion to THA included osteonecrosis, nonunion, and loss of fixation. Two others had periimplant subtrochanteric femur fractures treated by surgical repair with cephalomedullary nails and two patients had removal of hardware.
CONCLUSIONS: Revision surgery after osteosynthesis for stable femoral neck fractures was more frequent in this series than previously has been reported. The reasons for this higher frequency of reoperation may be related to poor bone quality, patient age, and some technical factors, which leads us to believe other treatment options such as nonoperative management or hemiarthroplasty may be viable options for some of these patients. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Entities:  

Mesh:

Year:  2014        PMID: 25256623      PMCID: PMC4397802          DOI: 10.1007/s11999-014-3957-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  33 in total

1.  Outcomes of elderly patients with nondisplaced femoral neck fractures. 2002.

Authors:  Jesse Eisler; Roger Cornwall; Elton Strauss; Kenneth Koval; Albert Siu; Marvin Gilbert
Journal:  J Orthop Trauma       Date:  2003-09       Impact factor: 2.512

2.  Internal fixation of femoral neck fractures. A follow-up study of 118 cases.

Authors:  K H Stappaerts; P L Broos
Journal:  Acta Chir Belg       Date:  1987 Jul-Aug       Impact factor: 1.090

3.  Undisplaced femoral neck fracture in the elderly.

Authors:  F Y Chiu; W H Lo
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

4.  Femoral neck fracture fixation with hook-pins. 2-year results and learning curve in 626 prospective cases.

Authors:  B Strömqvist; L T Nilsson; K G Thorngren
Journal:  Acta Orthop Scand       Date:  1992-06

5.  Surgical treatment of displaced femoral neck fractures in the elderly: a survey of the American Association of Hip and Knee Surgeons.

Authors:  Richard Iorio; Ben Schwartz; William Macaulay; Steven M Teeney; William L Healy; Sally York
Journal:  J Arthroplasty       Date:  2006-12       Impact factor: 4.757

6.  Undisplaced femoral neck fractures--no problems? A consecutive study of 224 patients treated with internal fixation.

Authors:  Cecilia Rogmark; Louise Flensburg; Hans Fredin
Journal:  Injury       Date:  2008-12-13       Impact factor: 2.586

7.  Outcome of undisplaced and moderately displaced femoral neck fractures.

Authors:  Kristian Bjørgul; Olav Reikerås
Journal:  Acta Orthop       Date:  2007-08       Impact factor: 3.717

8.  Treatment of nondisplaced fractures of the femoral neck.

Authors:  G Bentley
Journal:  Clin Orthop Relat Res       Date:  1980-10       Impact factor: 4.176

Review 9.  Undisplaced intracapsular hip fractures: results of internal fixation in 375 patients.

Authors:  Kevin S Conn; Martyn J Parker
Journal:  Clin Orthop Relat Res       Date:  2004-04       Impact factor: 4.176

10.  Treatment and displacement affect the reoperation rate for femoral neck fracture.

Authors:  Donavan K Murphy; Timmothy Randell; Kindyle L Brennan; Robert A Probe; Michael L Brennan
Journal:  Clin Orthop Relat Res       Date:  2013-05-03       Impact factor: 4.176

View more
  19 in total

1.  Is percutaneous screw fixation really superior to non-operative management after valgus-impacted femoral neck fracture: a retrospective cohort study.

Authors:  L Henry Goodnough; Harsh Wadhwa; Andrew T Fithian; Malcolm R DeBaun; Sean T Campbell; Michael J Gardner; Julius A Bishop
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-07-24

2.  Clinical results of treatment of garden type 1 and 2 femoral neck fractures in patients over 70-year old.

Authors:  S K Han; H S Song; R Kim; S H Kang
Journal:  Eur J Trauma Emerg Surg       Date:  2015-04-18       Impact factor: 3.693

3.  CORR Insights(®): Does Teriparatide Improve Femoral Neck Fracture Healing: Results From A Randomized Placebo-controlled Trial.

Authors:  Charles N Cornell
Journal:  Clin Orthop Relat Res       Date:  2016-03-11       Impact factor: 4.176

4.  Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.

Authors:  Matthias Knobe; Simon Altgassen; Klaus-Jürgen Maier; Gertraud Gradl-Dietsch; Chris Kaczmarek; Sven Nebelung; Kajetan Klos; Bong-Sung Kim; Boyko Gueorguiev; Klemens Horst; Benjamin Buecking
Journal:  Int Orthop       Date:  2017-08-06       Impact factor: 3.075

5.  Comparison of functional outcome of bipolar hip arthroplasty and total hip replacement in displaced femoral neck fractures in elderly in a developing country: a 2-year prospective study.

Authors:  Jayesh Chandrakant Sonaje; Pradeep Kumar Meena; Ramesh Chandra Bansiwal; Sandesh Satish Bobade
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-13

6.  [Comparison of effectiveness of femoral neck system and cannulate compression screw in treatment of femoral neck fracture in young and middle-aged patients].

Authors:  Caiping Yan; Xingkuan Wang; Chao Xiang; Ke Jiang; Yuling Li; Qian Chen; Changgong Deng; Lu Chen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-10-15

7.  Accuracy of guide wire placement for femoral neck stabilization using 3D printed drill guides.

Authors:  Gregory R Roytman; Alim F Ramji; Brian Beitler; Brad Yoo; Michael P Leslie; Michael Baumgaertner; Steven Tommasini; Daniel H Wiznia
Journal:  3D Print Med       Date:  2022-07-04

8.  The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.

Authors:  Michael Willey; Matthew L Welsh; Travis S Roth; Kenneth J Koval; James V Nepola
Journal:  Iowa Orthop J       Date:  2018

9.  [Research progress in treatment of femoral neck fracture in the elderly].

Authors:  Yangyang Zhou; Yingjie Ni; Xingjuan Li; Hui Chen; Yunfeng Rui
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-08-15

Review 10.  Recent advances in the treatment of hip fractures in the elderly.

Authors:  Joshua C Rozell; Mark Hasenauer; Derek J Donegan; Mark Neuman
Journal:  F1000Res       Date:  2016-08-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.