Literature DB >> 30104926

The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.

Michael Willey1, Matthew L Welsh2, Travis S Roth2, Kenneth J Koval2, James V Nepola1.   

Abstract

Recent estimates suggest an annual incidence of greater than 125,000 femoral neck fractures. Surgical treatment is indicated for the majority of these fractures, which are estimated to double by the year 2050. Most displaced femoral neck fractures in elderly patients are treated with arthroplasty secondary to high complication rates associated with internal fixation. Traditional implants used for internal fixation, typically in elderly patients with stable fracture morphology and younger patients regardless of morphology, include the sliding hip screw (SHS), with or without a supplemental anti-rotation screw, and multiple cancellous lag screws. Complications have been reported with both of these fixation techniques, especially as they apply to treating displaced femoral neck fractures in the elderly. Yet, complications of nonunion, loss of fixation and osteonecrosis, among others, still frequently occur in stable patterns of femoral neck fracture treated with internal fixation. Accordingly, additional implants have been designed recently to improve outcomes and avoid such complications in this population. The Targon Femoral Neck Plate (Aesculap, Tuttlinger, Germany) has been used in Europe for the treatment of both displaced and nondisplaced femoral neck fractures by combining a side plate and multiple cancellous lag screws. Multiple studies have shown superior rates of both nonunion and osteonecrosis when compared to the SHS and multiple cancellous screws in both displaced and nondisplaced femoral neck fractures. This article details the design rationale, surgical technique and early postoperative results of a new hybrid implant used for the treatment of both displaced and nondisplaced femoral neck fractures.

Entities:  

Mesh:

Year:  2018        PMID: 30104926      PMCID: PMC6047398     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  20 in total

1.  Vertical shear fractures of the femoral neck. A biomechanical study.

Authors:  A C Baitner; S G Maurer; D G Hickey; L M Jazrawi; F J Kummer; J Jamal; S Goldman; K J Koval
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

2.  Outcomes after displaced fractures of the femoral neck. A meta-analysis of one hundred and six published reports.

Authors:  G L Lu-Yao; R B Keller; B Littenberg; J E Wennberg
Journal:  J Bone Joint Surg Am       Date:  1994-01       Impact factor: 5.284

3.  Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients.

Authors:  M Parker; S Cawley; V Palial
Journal:  Bone Joint J       Date:  2013-10       Impact factor: 5.082

4.  Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients.

Authors:  J F Keating; A Grant; M Masson; N W Scott; J F Forbes
Journal:  J Bone Joint Surg Am       Date:  2006-02       Impact factor: 5.284

5.  Results of internal fixation of Pauwels type-3 vertical femoral neck fractures.

Authors:  Frank Liporace; Robert Gaines; Cory Collinge; George J Haidukewych
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

6.  Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques.

Authors:  Arash Aminian; Fan Gao; Wasyl W Fedoriw; Li-Qun Zhang; David M Kalainov; Bradley R Merk
Journal:  J Orthop Trauma       Date:  2007-09       Impact factor: 2.512

Review 7.  Undisplaced intracapsular hip fractures: results of internal fixation in 375 patients.

Authors:  Kevin S Conn; Martyn J Parker
Journal:  Clin Orthop Relat Res       Date:  2004-04       Impact factor: 4.176

8.  Angular stable multiple screw fixation (Targon FN) versus standard SHS for the fixation of femoral neck fractures.

Authors:  Anica Eschler; Susanne Brandt; Philip Gierer; Thomas Mittlmeier; Georg Gradl
Journal:  Injury       Date:  2013-10-28       Impact factor: 2.586

9.  Comparison analysis of the operative treatment results of the femoral neck fractures using side-plate and compression screw and cannulated AO screws.

Authors:  Jerzy Stiasny; Szymon Dragan; Mirosław Kulej; Jacek Martynkiewicz; Jerzy Płochowski; Szymon Łukasz Dragan
Journal:  Ortop Traumatol Rehabil       Date:  2008 Jul-Aug

10.  Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques.

Authors:  B Blair; K J Koval; F Kummer; J D Zuckerman
Journal:  Clin Orthop Relat Res       Date:  1994-09       Impact factor: 4.176

View more
  2 in total

1.  The Oval-like Cross-section of Femoral Neck Isthmus in Three-dimensional Morphological Analysis.

Authors:  Ru-Yi Zhang; Yan-Peng Zhao; Xiu-Yun Su; Jian-Tao Li; Jing-Xin Zhao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Orthop Surg       Date:  2021-01-08       Impact factor: 2.071

2.  Three-dimensional morphological analysis of the femoral neck torsion angle-an anatomical study.

Authors:  Ru-Yi Zhang; Xiu-Yun Su; Jing-Xin Zhao; Jian-Tao Li; Li-Cheng Zhang; Pei-Fu Tang
Journal:  J Orthop Surg Res       Date:  2020-05-27       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.