| Literature DB >> 25250313 |
Tzung-Chi Huang1, Kuei-Ting Chou2, Yao-Ching Wang3, Geoffrey Zhang4.
Abstract
PURPOSE: Respiratory motion presents significant challenges for accurate PET/CT. It often introduces apparent increase of lesion size, reduction of measured standardized uptake value (SUV), and the mismatch in PET/CT fusion images. In this study, we developed the motion freeze method to use 100% of the counts collected by recombining the counts acquired from all phases of gated PET data into a single 3D PET data, with correction of respiration by deformable image registration.Entities:
Mesh:
Year: 2014 PMID: 25250313 PMCID: PMC4164623 DOI: 10.1155/2014/167491
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Clinical characteristics of study subjects and tumors.
| Patient # | Sex | Age (y) | Histology | Location | Type | Stage |
|---|---|---|---|---|---|---|
| 1 | M | 64 | NSCLC | Right lower lobe | Lymph node | III |
| 2 | M | 59 | NSCLC | Left lower lobe | Lymph node | III |
| 3 | M | 63 | NSCLC | Right lower lobe | Lymph node | III |
| 4 | F | 57 | NSCLC | Left upper lobe | Lymph node | III |
| 5 | M | 61 | NSCLC | Right lower lobe | Lymph node | III |
| 6 | M | 64 | NSCLC | Left lower lobe | Lymph node | III |
*NSCLC = Non-small-cell lung carcinoma.
Figure 1Flow diagram of the motion freeze process used in this study.
Figure 2Example of deformable image registration using the 3D optical flow method to map the T5% PET to T55% PET. (a) A coronal view of the normal end-inspiration CT (T5%, original image) of 4D-CT. (b) The corresponding slice of the location in (a) at end-expiration CT (T55%, reference image) of 4D CT. (c) The calculated deformation vectors for the registration of original image to the reference. (d) The corresponding T5% PET with the 3D OFM deformation vectors superimposed.
Figure 3The coronal views of the fused PET/CT images from (a) 3D, (b) 4D (best bin), (c) motion freeze technology for patient number 4. A lesion in the left upper lobe of the lung and artifacts around the right diaphragm were observed on the 3D HCT images, and (d) vertical image profiles drawn across the lesion on PET3D, PET4D, and PETMF images. Black arrow indicated the lesion area and the dotted black arrow indicated the diaphragm region.
Summary of different quantitative results for 3D, 4D, and motion freeze methods.
| Patient number | SUVmean | SUVmax | Tumor Volume (cm3) | ||||||
|---|---|---|---|---|---|---|---|---|---|
| PET3D | PET4D | PETMF | PET3D | PET4D | PETMF | PET3D | PET4D | PETMF | |
| 1 | 7.4 | 7.5 | 7.6 | 13.5 | 13.7 | 13.9 | 68.2 | 51.1 | 50.2 |
| 2 | 7.7 | 7.9 | 7.9 | 13.2 | 15.3 | 15.8 | 173.1 | 144.7 | 140.0 |
| 3 | 6.6 | 8.2 | 8.4 | 12.4 | 14.8 | 16.3 | 120.0 | 109.4 | 100.8 |
| 4 | 2.6 | 3.3 | 4.7 | 9.9 | 9.9 | 10.0 | 22.0 | 14.7 | 12.7 |
| 5 | 1.8 | 1.8 | 2.1 | 8.2 | 9.3 | 9.8 | 132.2 | 128.0 | 123.1 |
| 6 | 3.0 | 3.8 | 4.4 | 14.8 | 15.9 | 15.9 | 42.2 | 34.8 | 27.6 |
Summary of tumor motion estimations and differences of centroid of the tumors.
| Patient number | Deformation of tumor motion (mm) |
| |||||
|---|---|---|---|---|---|---|---|
| AP | LAT | SI | TD | 3D-PET/HCT | 4D-PET/CT | PETMF/CTT55% | |
| 1 | 1.1 ± 1.0 | 0.9 ± 0.9 | 7.3 ± 2.6 | 7.7 ± 2.6 | 22.7 | 16.4 | 11.4 |
| 2 | 1.9 ± 1.2 | 1.4 ± 1.0 | 3.1 ± 1.4 | 4.4 ± 1.1 | 6.1 | 5.5 | 4.6 |
| 3 | 0.9 ± 1.2 | 0.5 ± 0.5 | 2.5 ± 1.9 | 2.88 ± 2.3 | 15.5 | 10.5 | 10.4 |
| 4 | 0.6 ± 0.5 | 0.9 ± 1 | 2.6 ± 1 | 3.0 ± 0.8 | 7.1 | 3.1 | 1.4 |
| 5 | 3.2 ± 2.2 | 2.5 ± 2.2 | 3.6 ± 1.9 | 5.9 ± 2.6 | 13.5 | 6.1 | 5.7 |
| 6 | 3.6 ± 2.5 | 1.2 ± 0.8 | 8.5 ± 5.4 | 9.6 ± 2.1 | 7.7 | 5.2 | 2.3 |