Literature DB >> 18396177

Respiratory motion in positron emission tomography/computed tomography: a review.

Sadek A Nehmeh1, Yusuf E Erdi.   

Abstract

The development of positron emission tomography/computed tomography (PET/CT) scanners has allowed not only straightforward but also synergistic fusion of anatomical and functional information. Combined PET/CT imaging yields an increased sensitivity and specificity beyond that which either of the 2 modalities possesses separately and therefore provides improved diagnostic accuracy. Because attenuation correction in PET is performed with the use of CT images, with CT used in the localization of disease, accurate spatial registration of PET and CT image sets is required. Correcting for the spatial mismatch caused by respiratory motion represents a particular challenge for the requisite registration accuracy as a result of differences in temporal resolution between the 2 modalities. This review provides a brief summary of the materials, methods, and results involved in multiple investigations of the correction for respiratory motion in PET/CT imaging of the thorax, with the goal of improving image quality and quantitation. Although some schemes use respiratory-phase data selection to exclude motion artifacts, others have adopted sophisticated software techniques. The various image artifacts associated with breathing motion are also described.

Mesh:

Year:  2008        PMID: 18396177     DOI: 10.1053/j.semnuclmed.2008.01.002

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  80 in total

1.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

Review 2.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

3.  Optimization of an on-board imaging system for extremely rapid radiation therapy.

Authors:  Erica M Cherry Kemmerling; Meng Wu; He Yang; Peter G Maxim; Billy W Loo; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

4.  Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI.

Authors:  Ryogo Minamimoto; Craig Levin; Mehran Jamali; Dawn Holley; Amir Barkhodari; Greg Zaharchuk; Andrei Iagaru
Journal:  Mol Imaging Biol       Date:  2016-10       Impact factor: 3.488

Review 5.  Positron emission tomography imaging approaches for external beam radiation therapies: current status and future developments.

Authors:  P M Price; M M Green
Journal:  Br J Radiol       Date:  2011-03-22       Impact factor: 3.039

6.  Respiratory-induced errors in tumor quantification and delineation in CT attenuation-corrected PET images: effects of tumor size, tumor location, and respiratory trace: a simulation study using the 4D XCAT phantom.

Authors:  Parham Geramifar; Mojtaba Shamsaie Zafarghandi; Pardis Ghafarian; Arman Rahmim; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2013-12       Impact factor: 3.488

7.  Effect of the positron range of 18F, 68Ga and 124I on PET/CT in lung-equivalent materials.

Authors:  Gerrit J Kemerink; Mariëlle G W Visser; Renee Franssen; Emiel Beijer; Mariangela Zamburlini; Servé G E A Halders; Boudewijn Brans; Felix M Mottaghy; Gerrit J J Teule
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-02       Impact factor: 9.236

8.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

9.  Amplitude-based optimal respiratory gating in positron emission tomography in patients with primary lung cancer.

Authors:  Willem Grootjans; Lioe-Fee de Geus-Oei; Antoi P W Meeuwis; Charlotte S van der Vos; Martin Gotthardt; Wim J G Oyen; Eric P Visser
Journal:  Eur Radiol       Date:  2014-08-06       Impact factor: 5.315

10.  Respiration-averaged CT for attenuation correction in non-small-cell lung cancer.

Authors:  Nai-Ming Cheng; Chih-Teng Yu; Kung-Chu Ho; Yi-Cheng Wu; Yuan-Chang Liu; Chih-Wei Wang; Tzu-Chen Yen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-03       Impact factor: 9.236

View more